{"product_id":"siemens-6av7885-2ak21-1da8-simatic-hmi-ipc-577c-panel-pc","title":"Siemens 6AV7885-2AK21-1DA8 SIMATIC HMI IPC 577C Panel PC","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis is a Siemens 6AV7885-2AK21-1DA8, a SIMATIC HMI IPC 577C series industrial panel PC designed for machine-level control and visualization tasks. The unit integrates a \u003cstrong\u003e15-inch touch display\u003c\/strong\u003e and is powered by an Intel \u003cstrong\u003eCore 2 Duo 1.86 GHz\u003c\/strong\u003e processor with \u003cstrong\u003e2 GB of DDR3 RAM\u003c\/strong\u003e. It provides robust connectivity with dual \u003cstrong\u003e1 Gbit PROFINET (IE)\u003c\/strong\u003e ports, standard Ethernet, and multiple USB interfaces. The system is equipped with a \u003cstrong\u003e320 GB SATA HDD\u003c\/strong\u003e pre-installed with Windows XP Professional and includes a DVD RW drive for flexible data handling. A single PCI slot allows for hardware expansion.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003e15-inch resistive touch screen display for operator interface\u003c\/li\u003e\n  \u003cli\u003eIntel Core 2 Duo processor operating at 1.86 GHz\u003c\/li\u003e\n  \u003cli\u003e2 GB of DDR3 system memory\u003c\/li\u003e\n  \u003cli\u003e320 GB SATA Hard Disk Drive for primary storage\u003c\/li\u003e\n  \u003cli\u003eIntegrated DVD RW optical drive\u003c\/li\u003e\n  \u003cli\u003eDual 1 Gbit PROFINET (IE) interfaces for industrial networking\u003c\/li\u003e\n  \u003cli\u003eStandard 10\/100\/1000 Mbps Ethernet port\u003c\/li\u003e\n  \u003cli\u003eOne available PCI slot for expansion cards\u003c\/li\u003e\n  \u003cli\u003eOperates on a 24 V DC power supply\u003c\/li\u003e\n  \u003cli\u003ePre-installed with Windows XP Professional operating system\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003eMachine-level Human Machine Interface (HMI)\u003c\/li\u003e\n  \u003cli\u003eProcess visualization and control\u003c\/li\u003e\n  \u003cli\u003eData acquisition and logging systems\u003c\/li\u003e\n  \u003cli\u003eManufacturing Execution Systems (MES) terminals\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation control panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n    \u003cthead style=\"background-color: #f7fafc;\"\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; text-align: left; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; text-align: left; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eModel\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e6AV7885-2AK21-1DA8\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSIMATIC HMI IPC 577C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePanel PC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePhase-Out\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eIntel Core 2 Duo, 1.86 GHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eMemory (RAM)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e2 GB DDR3\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eDisplay\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e15-inch Touch Display\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePrimary Storage\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e320 GB HDD SATA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSecondary Storage\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eDVD RW\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eWindows XP Professional (Pre-installed)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e24 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eEthernet Port\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e1x 10\/100\/1000 Mbps\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePROFINET Interface\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e2x 1 Gbit (IE)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eUSB Ports\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e4x Rear, 1x Front\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eExpansion Slots\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e1x PCI\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePackage Dimensions\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e64.0 x 64.0 x 42.0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e15.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin: 20px 0;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Installation, commissioning, and maintenance must be performed by qualified, trained personnel only. Disconnect all power sources before installation to prevent electric shock and equipment damage. Adhere to all local and national safety regulations, including Lockout\/Tagout (LOTO) procedures.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eDe-energize Equipment:\u003c\/strong\u003e Before starting, ensure the control cabinet and all related machinery are completely de-energized and locked out. Verify the absence of voltage.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003ePrepare Panel Cutout:\u003c\/strong\u003e Verify that the panel cutout dimensions match the IPC 577C's mounting requirements. Ensure the mounting surface is clean, flat, and rigid enough to support the unit's weight.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eMount the Unit:\u003c\/strong\u003e Insert the Panel PC into the cutout from the front. Secure it from the rear using the provided mounting clamps, tightening them evenly to ensure a proper seal and secure fit.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eConnect Protective Earth:\u003c\/strong\u003e Connect the main protective earth (PE) terminal on the unit to the cabinet's central grounding point using a low-impedance conductor of the appropriate gauge. This is critical for safety and noise immunity.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eConnect Power:\u003c\/strong\u003e Connect the 24 V DC power supply to the designated power input terminals, observing correct polarity. Use appropriately sized wiring for the load.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eConnect Interfaces:\u003c\/strong\u003e Connect PROFINET, Ethernet, USB, and any other required peripheral cables. Ensure all connectors are fully seated and secured. Route cables to prevent strain and interference.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e7\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eFinal Check and Power-Up:\u003c\/strong\u003e After a final inspection of all connections, remove locks\/tags and re-energize the cabinet. The Panel PC will boot, and commissioning can proceed.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715805016427,"sku":"6AV7885-2AK21-1DA8","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7885-2ak21-1da8-nydaycj5wj3_f8d5002a-de56-4c1b-a3a1-89ab89429628.jpg?v=1767071250","url":"https:\/\/www.plcprotech.com\/de\/products\/siemens-6av7885-2ak21-1da8-simatic-hmi-ipc-577c-panel-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}