{"product_id":"siemens-6es7412-1xj07-0ab0-simatic-s7-400-cpu-412-1-module","title":"Siemens 6ES7412-1XJ07-0AB0 SIMATIC S7-400 CPU 412-1 Module","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis is a Siemens SIMATIC S7-400, CPU 412-1 central processing unit, part number 6ES7412-1XJ07-0AB0. It is engineered for mid-range control tasks within the S7-400 modular automation system. The module is equipped with a total \u003cstrong\u003e512 KB\u003c\/strong\u003e of work memory, divided equally into \u003cstrong\u003e256 KB for program code\u003c\/strong\u003e and \u003cstrong\u003e256 KB for data\u003c\/strong\u003e. For system connectivity, it includes an integrated \u003cstrong\u003eMPI\/DP interface\u003c\/strong\u003e with a communication speed of \u003cstrong\u003e12 Mbit\/s\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n  \u003cli\u003eTotal work memory of 512 KB for user programs and data.\u003c\/li\u003e\n  \u003cli\u003eDedicated 256 KB memory for program code execution.\u003c\/li\u003e\n  \u003cli\u003eDedicated 256 KB memory for process data storage.\u003c\/li\u003e\n  \u003cli\u003eIntegrated MPI\/DP (Multi-Point Interface\/Distributed Peripherals) port.\u003c\/li\u003e\n  \u003cli\u003eSupports communication speeds up to 12 Mbit\/s.\u003c\/li\u003e\n  \u003cli\u003eDesigned for the modular and scalable SIMATIC S7-400 platform.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n  \u003cli\u003eProcess control in chemical, pharmaceutical, and food \u0026amp; beverage industries.\u003c\/li\u003e\n  \u003cli\u003eManufacturing automation and assembly line control.\u003c\/li\u003e\n  \u003cli\u003eCoordinated drive control and motion applications.\u003c\/li\u003e\n  \u003cli\u003eData acquisition and supervision in plant-wide systems.\u003c\/li\u003e\n  \u003cli\u003ePower generation and distribution management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e2e8f0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background-color: #f7fafc; padding: 10px 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748; font-weight: 600;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"background-color: #f7fafc; padding: 10px 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748; font-weight: 600;\"\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProduct Series\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSIMATIC S7-400\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eModule Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eCPU 412-1 Central Processing Unit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003ePart Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e6ES7412-1XJ07-0AB0\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eWork Memory (Total)\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e512 KB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eWork Memory (Code)\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e256 KB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eWork Memory (Data)\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e256 KB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eIntegrated Interface\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eMPI\/DP\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eInterface Speed\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e12 Mbit\/s\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003ePLC Architecture\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eModular\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eActive\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003ePredecessor Part Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e6ES7412-1XJ05-0AB0\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eShipping Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e0.50 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProduct Dimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e2.50 x 29.00 x 21.90 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e5 x 31 x 24 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eCommodity Code (HS)\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e85371091\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eECCN\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eEAR99\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eGermany (Estimated)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 12px 16px; margin-bottom: 16px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Disconnect all power sources from the S7-400 rack and follow all Lock-Out\/Tag-Out (LOTO) procedures before attempting to install or remove this module. Failure to de-energize the system can result in electric shock, equipment damage, and unintended machine operation. This module contains components sensitive to electrostatic discharge (ESD).\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003eEnsure the S7-400 rack is completely de-energized and verified to be in a zero-energy state.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003eUse a grounded wrist strap and handle the CPU module by its edges or front plate to prevent ESD damage to sensitive electronics.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003eSelect the designated CPU slot in the S7-400 rack. Align the module with the top and bottom guide rails.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003eSlide the module into the rack until its backplane connector makes firm contact with the rack's bus connector. Ensure it is fully seated.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003eTighten the retaining screws on the front panel of the module to secure it to the rack frame. Do not overtighten.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e6\u003c\/span\u003e\n    \u003cspan\u003eConnect the MPI\/DP communication cable to the corresponding port on the front of the CPU. Ensure the connector is securely fastened.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e7\u003c\/span\u003e\n    \u003cspan\u003eOnce all modules are installed and connections are verified, remove LOTO devices and re-apply power to the system for commissioning.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716743557483,"sku":"6ES7412-1XJ07-0AB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7412-1xj07-0ab0-5fumhsqnc0v_7e2f2545-aa65-4ace-b7ea-06de7a135de4.jpg?v=1767088595","url":"https:\/\/www.plcprotech.com\/de\/products\/siemens-6es7412-1xj07-0ab0-simatic-s7-400-cpu-412-1-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}