{"product_id":"siemens-6fc5210-0df02-0aa0-sinumerik-pcu-50-controller","title":"Siemens 6FC5210-0DF02-0AA0 SINUMERIK PCU 50 Steuerungseinheit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSiemens 6FC5210-0DF02-0AA0\u003c\/strong\u003e is a \u003cstrong\u003eSINUMERIK PCU 50\u003c\/strong\u003e industrial computer unit tailored for the \u003cstrong\u003eSINUMERIK 840D\u003c\/strong\u003e automation platform. Engineered for robust performance, it features a \u003cstrong\u003ePentium II 333 MHz\u003c\/strong\u003e processor and \u003cstrong\u003e128 MB\u003c\/strong\u003e of RAM. The unit operates on a \u003cstrong\u003e24 V DC\u003c\/strong\u003e power supply and comes pre-configured with \u003cstrong\u003eWindows NT 4.0\u003c\/strong\u003e and \u003cstrong\u003eHMI Advanced\u003c\/strong\u003e software. This controller is designed to provide stable, reliable computational power for high-precision machine tool control and complex manufacturing environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePentium II 333 MHz processor for stable industrial computing\u003c\/li\u003e\n\u003cli\u003e128 MB RAM for effective data management\u003c\/li\u003e\n\u003cli\u003ePre-installed Windows NT 4.0 operating system\u003c\/li\u003e\n\u003cli\u003eIncludes HMI Advanced software for machine interface\u003c\/li\u003e\n\u003cli\u003e24 V DC power operation\u003c\/li\u003e\n\u003cli\u003eOptimized for SINUMERIK 840D integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSINUMERIK 840D CNC machine tool control\u003c\/li\u003e\n\u003cli\u003eIndustrial automation and production monitoring\u003c\/li\u003e\n\u003cli\u003eLegacy manufacturing system maintenance\u003c\/li\u003e\n\u003cli\u003eHigh-precision motion control interfaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eSINUMERIK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eControllers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003ePentium II 333 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e128 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating System\u003c\/td\u003e\n\u003ctd\u003eWindows NT 4.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003ePhase-out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (cm)\u003c\/td\u003e\n\u003ctd\u003e48.0 x 31.0 x 5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e6.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85371010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the PCU in an appropriate operator panel enclosure to maintain IP protection standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Ensure adequate airflow around the unit to prevent thermal buildup within the cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the chassis to a verified earth ground to minimize electromagnetic interference and ensure operator safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware:\u003c\/strong\u003e Verify that the HMI Advanced software version is fully compatible with the specific SINUMERIK 840D control unit hardware revision.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance:\u003c\/strong\u003e Due to the legacy nature of this hardware, periodically check cooling fans and cabling to ensure continued operational integrity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716781699435,"sku":"6FC5210-0DF02-0AA0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6fc5210-0df02-0aa0-o0komfuv4df_6d423b4f-859b-44ee-92d0-81cbe3f26bbe.jpg?v=1767089564","url":"https:\/\/www.plcprotech.com\/de\/products\/siemens-6fc5210-0df02-0aa0-sinumerik-pcu-50-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}