{"product_id":"siemens-6md1023-0aa00-sicam-rtu-control-release","title":"Siemens 6MD1023-0AA00 SICAM RTU Control Release","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e6MD1023-0AA00\u003c\/strong\u003e is a \u003cstrong\u003eSICAM RTU Control Release\u003c\/strong\u003e module designed for process control and system monitoring tasks. This unit features 8 indications and 8 command release outputs, along with 8 single indications for internal system alarms. It provides a flexible output configuration consisting of 4 double-throw contacts and 4 make contacts, which can be utilized for both process and system-specific operations. The module includes an internal output safety switch and supports time-independent command output. It is engineered to handle various ohmic loads and operates within a specified input voltage range of 24V to 60V DC.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommand\/Indication Capacity:\u003c\/strong\u003e 8 indications, 8 command releases, 8 internal system alarm indications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Configuration:\u003c\/strong\u003e 4 double-throw contacts, 4 make contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Safety:\u003c\/strong\u003e Integrated internal output safety switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Handling (Ohmic):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e24V: up to 4.0 A\u003c\/li\u003e\n\u003cli\u003e48V: up to 1.3 A\u003c\/li\u003e\n\u003cli\u003e60V: up to 0.9 A\u003c\/li\u003e\n\u003cli\u003e125V: up to 0.4 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 24V – 60V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRemote Terminal Unit (RTU) control systems\u003c\/li\u003e\n\u003cli\u003eProcess control for electrical power and substation automation\u003c\/li\u003e\n\u003cli\u003eSystem monitoring and fault alarm management\u003c\/li\u003e\n\u003cli\u003eIntegration into SICAM automation architectures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eSicam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRTU Control Release\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e24 - 60 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e23 cm x 17 cm x 7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.57 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch2\u003eInstallation Guidelines\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Ensure installation in a clean, dry control environment within a SICAM RTU housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect process and system tasks to the designated double-throw or make contacts, ensuring cable gauges are appropriate for the required current load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Compliance:\u003c\/strong\u003e Strictly adhere to the 24V to 60V DC input voltage range to prevent damage to the control module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e Verify that the internal output safety switch is correctly configured for the intended safety functions of the system application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Maintain proper chassis grounding to ensure consistent performance and signal integrity for internal alarm indications.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716777701739,"sku":"6MD1023-0AA00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6md1023-0aa00-uzyhojyuuqx_06d13a51-439d-4e6e-a538-1c60fc849bd7.jpg?v=1767089427","url":"https:\/\/www.plcprotech.com\/de\/products\/siemens-6md1023-0aa00-sicam-rtu-control-release","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}