{"product_id":"siemens-7me6910-2ca10-1aa0-mag-5000-transmitter","title":"Siemens 7ME6910-2CA10-1AA0 MAG 5000 Transmitter","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e7ME6910-2CA10-1AA0\u003c\/strong\u003e is a \u003cstrong\u003eMAG 5000 electromagnetic flow transmitter\u003c\/strong\u003e designed for high-performance measurement in various industrial fluid applications. Engineered for integration into 19-inch rack systems, this transmitter (insert version) features a robust aluminum construction and is rated IP20 \/ NEMA 2 for indoor panel mounting environments. This unit operates on a wide voltage supply range of 115-230V AC at 50\/60 Hz, ensuring compatibility with standard industrial power grids. The \u003cstrong\u003eMAG 5000 series\u003c\/strong\u003e is recognized for its straightforward operation and reliability in flow monitoring within process control systems.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e19-inch insert design for rack mounting\u003c\/li\u003e\n\u003cli\u003eRobust aluminum enclosure\u003c\/li\u003e\n\u003cli\u003eDesigned for IP20 \/ NEMA 2 protection class\u003c\/li\u003e\n\u003cli\u003eWide input power range: 115-230V AC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-performance signal processing for electromagnetic flow sensors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWater and wastewater management\u003c\/li\u003e\n\u003cli\u003eChemical and pharmaceutical processing\u003c\/li\u003e\n\u003cli\u003eIndustrial process flow monitoring\u003c\/li\u003e\n\u003cli\u003eEnergy and power plant auxiliary systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eMAG 5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFlow Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003e19 Inch Insert\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e115-230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 \/ NEMA 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003eAluminium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e32.00 cm x 23.00 cm x 17.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.07 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch2\u003eInstallation Guidelines\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Designed for installation in a standard 19-inch equipment rack or control panel. Ensure adequate clearance for airflow to prevent overheating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e The unit is rated IP20; ensure installation in a clean, dry, and climate-controlled environment, away from direct moisture, dust, or corrosive vapors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e Verify the local supply voltage is within the 115-230V AC range before connection. Ensure all electrical connections are tightened to prevent voltage drops or intermittent signaling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Proper grounding of the 19-inch rack and the transmitter chassis is essential for electromagnetic compatibility (EMC) and to maintain measurement accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Keep signal cables separated from high-voltage power lines to minimize induced interference on the flow measurement signals.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716778094955,"sku":"7ME6910-2CA10-1AA0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/7me6910-2ca10-1aa0-ekzd0jr1rbe_28f9baf1-8c1b-43a0-9a1f-06eb2a56987a.jpg?v=1767089444","url":"https:\/\/www.plcprotech.com\/de\/products\/siemens-7me6910-2ca10-1aa0-mag-5000-transmitter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}