{"product_id":"siemens-scalance-xr524-8c-6gk5524-8gs00-2ar2-managed-layer-3-ie-switch","title":"Siemens SCALANCE XR524-8C 6GK5524-8GS00-2AR2 Managed Layer 3 IE Switch","description":"\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6GK5524-8GS00-2AR2 is a SCALANCE XR524-8C managed Layer 3 Industrial Ethernet switch designed for control-level networking and plant-wide communication. This unit operates on a \u003cstrong\u003e24 V DC\u003c\/strong\u003e power supply and provides high-density connectivity with a total of \u003cstrong\u003e24 usable ports\u003c\/strong\u003e, including copper RJ45 and fiber optic SFP interfaces. As a \u003cstrong\u003eLayer 3\u003c\/strong\u003e device, it supports routing functions for network segmentation. Its robust feature set includes integrated redundancy functions and native support as a \u003cstrong\u003ePROFINET IO Device\u003c\/strong\u003e, making it suitable for high-availability industrial automation systems.\u003c\/p\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n\u003cli\u003eLayer 3 management with routing capabilities\u003c\/li\u003e\n\u003cli\u003eFunctions as a PROFINET IO Device for seamless TIA integration\u003c\/li\u003e\n\u003cli\u003eHigh port density with 24 total usable 10\/100\/1000 Mbit\/s ports\u003c\/li\u003e\n\u003cli\u003eFlexible connectivity with 8 combo ports (RJ45 or SFP)\u003c\/li\u003e\n\u003cli\u003eIntegrated redundancy functions for high network availability\u003c\/li\u003e\n\u003cli\u003eSupports standard office network features (RSTP, VLAN, IGMP)\u003c\/li\u003e\n\u003cli\u003eEquipped with an error signaling contact for diagnostics\u003c\/li\u003e\n\u003cli\u003eIncludes a C-PLUG in the scope of delivery for configuration backup and transfer\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n\u003cli\u003ePlant-wide network backbones in manufacturing facilities\u003c\/li\u003e\n\u003cli\u003eControl-level networking in process automation and control systems\u003c\/li\u003e\n\u003cli\u003eSegmentation of large industrial networks using routing\u003c\/li\u003e\n\u003cli\u003eIntegration of automation cells into the enterprise network\u003c\/li\u003e\n\u003cli\u003eHigh-availability and redundant network structures\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; background-color: #f7fafc;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; background-color: #f7fafc;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSCALANCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eModel Number\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSCALANCE XR524-8C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e6GK5524-8GS00-2AR2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eManaged Layer 3 IE Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eRJ45 Ports\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e24 x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSFP Ports\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e8 x 100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCombo Ports\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eTotal Usable Ports\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eIndustrial Protocol\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePROFINET IO Device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSupported Office Features\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eRSTP, VLAN, IGMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e4.50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e44.90 cm x 4.40 cm x 30.50 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCommodity Code\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eECCN\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e5A002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCountry of Origin (Estimate)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e50 cm x 40 cm x 10 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"padding: 15px; background-color: #fff5f5; border-left: 5px solid #c53030; margin-bottom: 15px;\"\u003e\n\u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical Hazard. Installation must be performed by qualified personnel only. De-energize all power sources and follow Lockout\/Tagout (LOTO) procedures before accessing terminals or making connections. Failure to do so can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n\u003cli style=\"margin-bottom: 10px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 10px;\"\u003e1\u003c\/span\u003e\nEnsure the control cabinet is de-energized and verified to be in a zero-energy state before beginning installation.\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 10px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 10px;\"\u003e2\u003c\/span\u003e\nSecurely mount the switch into a standard 19-inch industrial rack or cabinet using the appropriate mounting hardware. Ensure adequate ventilation space around the unit.\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 10px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 10px;\"\u003e3\u003c\/span\u003e\nConnect the functional earth (FE) or protective earth (PE) terminal on the switch chassis to the cabinet's main grounding point using a low-impedance conductor.\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 10px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 10px;\"\u003e4\u003c\/span\u003e\nTerminate the 24 V DC power supply wiring to the designated power input terminals, observing correct polarity. Use appropriately sized conductors for the load.\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 10px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 10px;\"\u003e5\u003c\/span\u003e\nIf using configuration backup, insert the C-PLUG into its designated slot on the device.\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 10px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 10px;\"\u003e6\u003c\/span\u003e\nConnect network cables to the RJ45 ports and\/or insert SFP transceivers and connect fiber optic cables as required by the network design.\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 10px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 10px;\"\u003e7\u003c\/span\u003e\nOnce all connections are secure, close the cabinet, remove LOTO devices, and re-energize the system. Verify correct operation via the device status LEDs.\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716393169259,"sku":"6GK5524-8GS00-2AR2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5524-8gs00-2ar2-ntxiyfjksp4_d4711036-9d59-47de-99db-e75b1e239a16.jpg?v=1767081968","url":"https:\/\/www.plcprotech.com\/de\/products\/siemens-scalance-xr524-8c-6gk5524-8gs00-2ar2-managed-layer-3-ie-switch","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}