{"product_id":"weidmuller-1504350000-ie-sw-vl05mt-3tx-2sc-valueline-managed-industrial-ethernet-switch","title":"Weidmuller 1504350000 IE-SW-VL05MT-3TX-2SC ValueLine Managed Industrial Ethernet Switch","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEngineered to maintain reliable communication links in high-interference environments, the \u003cstrong\u003eWeidmuller 1504350000 IE-SW-VL05MT-3TX-2SC\u003c\/strong\u003e is a managed ValueLine Industrial Ethernet Switch featuring three RJ45 ports and two multimode SC-Duplex fiber optic ports. This device provides robust network management, ring redundancy, and traffic prioritization directly at the field level, making it ideal for critical infrastructure and demanding automation networks.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManaged Network Control:\u003c\/strong\u003e Supports essential management functions including VLAN, QoS, IGMP Snooping, and port mirroring for optimized bandwidth control.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFiber Optic Connectivity:\u003c\/strong\u003e Equipped with two 100BaseFX multimode fiber ports utilizing SC-Duplex connectors for noise-immune data transmission up to 5 km.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWide Temperature Range:\u003c\/strong\u003e Certified for operation in extreme environments from -40 degC to 75 degC without active cooling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRedundant Power Inputs:\u003c\/strong\u003e Dual 12\/24\/48 V DC power inputs ensure continuous operation in the event of a primary power supply failure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial-Grade Housing:\u003c\/strong\u003e Housed in a rugged IP30-rated metal enclosure designed to withstand high mechanical shock and vibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eWind power generation and solar farm monitoring networks.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment facility control systems.\u003c\/li\u003e\n  \u003cli\u003eFactory automation and machine-to-machine (M2M) communication.\u003c\/li\u003e\n  \u003cli\u003eOil and gas pipeline monitoring and distributed RTU networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eArticle Number \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1504350000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIE-SW-VL05MT-3TX-2SC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSwitch Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eManaged (ValueLine)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eRJ45 Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3x 10\/100BaseT(X), auto negotiation, full\/half duplex, auto MDI\/MDI-X\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eFiber Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2x 100BaseFX, Multimode, SC-Duplex connector\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTransmission Distance\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e5 km (typical over 50\/125 or 62.5\/125 um multimode fiber)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWavelength\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1310 nm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eInput Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e12 \/ 24 \/ 48 V DC (Redundant inputs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-40 degC to 75 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-40 degC to 85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eAmbient Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMAC Table Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2 K\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePacket Buffer Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1 Mbit\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eHousing Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMetal (IP30 protection degree)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMounting Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDIN rail (TS 35), Panel mounting (with optional kit)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e53.6 mm x 135 mm x 105 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e650 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1.5 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eTerminal Pin\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eSignal Assignment\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eDescription\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 1\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eV1+\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDC Power Input 1 (Positive)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 2\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eV1-\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDC Power Input 1 (Negative \/ Common)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 3\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSTATE (NC)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eFault Relay Output (Normally Closed)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSTATE (COM)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eFault Relay Output (Common)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 5\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eV2+\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDC Power Input 2 (Positive)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 6\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eV2-\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDC Power Input 2 (Negative \/ Common)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThis managed switch serves as a direct upgrade to the unmanaged IE-SW-VL05-3TX-2SC series, offering advanced diagnostics and ring redundancy protocols (such as Turbo Ring or RSTP) to prevent network loops. When replacing older revisions, verify that the existing network management software or PLC configuration supports standard SNMP or the specific Weidmuller ring topology parameters.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen deploying the multimode SC-Duplex ports over long distances, ensure that the total optical power budget does not exceed the receiver's saturation limits. For short-run fiber connections (under 100 meters), optical attenuators are generally not required, but clean fiber end-faces are critical to prevent packet loss. Ensure the switch is mounted vertically on the DIN rail to facilitate natural convection cooling, especially when operating near the upper thermal limit of 75 degC.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo ensure electromagnetic compatibility (EMC), connect the functional earth (FE) terminal on the DIN-rail ground block directly to a low-impedance earth ground. When wiring the redundant power inputs, use a wire gauge between 12 and 24 AWG. Tighten the terminal block screws to a torque of 0.5 Nm to prevent loose connections under high-vibration conditions.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eDe-energize all power sources before connecting or disconnecting the 6-pin terminal block. Do not insert or remove fiber optic cables while the transceiver is active to avoid potential eye injury from invisible laser radiation.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eSnap the switch onto the TS 35 DIN rail, ensuring the top hook engages first, then push the bottom of the unit until the metal latch clicks securely into place.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the functional ground terminal to the local protective earth system using a short, heavy-gauge wire.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eInsert the RJ45 copper network cables and the SC-Duplex multimode fiber optic cables into their designated ports until they lock in place.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWire the redundant power supplies to the 6-pin terminal block, plug the block into the switch, and apply power to verify status via the front-panel LED indicators.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102131183979,"sku":"IE-SW-VL05MT-3TX-2SC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-sw-vl05mt-3tx-2sc-zzabviscdoc.png?v=1776137765","url":"https:\/\/www.plcprotech.com\/de\/products\/weidmuller-1504350000-ie-sw-vl05mt-3tx-2sc-valueline-managed-industrial-ethernet-switch","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}