{"product_id":"weidmuller-8965360000-act20x-hdi-sdo-s-isolating-switch-amplifier","title":"Weidmuller 8965360000 ACT20X-HDI-SDO-S Isolating Switch Amplifier","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProcessing digital signals from hazardous areas requires robust galvanic isolation, which the \u003cstrong\u003eWeidmuller 8965360000 ACT20X-HDI-SDO-S\u003c\/strong\u003e delivers as a high-performance, 2-channel isolating switch amplifier. This device safely transmits switching states from NAMUR sensors or mechanical contacts located in Zone 0, 1, or 2 hazardous areas to the safe area control system, providing complete electrical separation and signal conditioning in a compact form factor.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eDual-channel intrinsically safe input for NAMUR sensors or dry mechanical contacts.\u003c\/li\u003e\n  \u003cli\u003eGalvanic 4-way isolation between input, output, power supply, and status output.\u003c\/li\u003e\n  \u003cli\u003eIntegrated line fault detection (LFD) for continuous wire-break and short-circuit monitoring.\u003c\/li\u003e\n  \u003cli\u003eFDT\/DTM software-configurable parameters for custom application tuning and diagnostics.\u003c\/li\u003e\n  \u003cli\u003eRelay outputs (1 changeover contact per channel) for robust load switching.\u003c\/li\u003e\n  \u003cli\u003eCompact 22.5 mm DIN-rail housing to optimize cabinet space.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eIntrinsically safe signal isolation in chemical and petrochemical processing plants.\u003c\/li\u003e\n  \u003cli\u003eOil and gas pipeline monitoring systems requiring Zone 0\/1 sensor deployment.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment facility telemetry and pump control.\u003c\/li\u003e\n  \u003cli\u003eHazardous area valve position feedback and limit switch integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eArticle Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e8965360000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eModel\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eACT20X-HDI-SDO-S\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eNumber of Channels\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eInput Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNAMUR sensor (DIN EN 60947-5-6) or mechanical switch\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eOutput Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eRelay (1 changeover contact per channel)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eNominal Switching Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e250 V AC \/ 30 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e19.2 to 31.2 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e\u0026lt;= 1.1 W\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eIsolation Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2.6 kV AC (input \/ output \/ power)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eConnection Technology\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eScrew connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eClamping Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.5 to 2.5 mm2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eFlammability Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUL 94 V-0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eProtection Degree\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-20 to +60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e117.2 mm x 22.5 mm x 113.6 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.170 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eTerminal Pin\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003e11 \/ 12\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eChannel 1 Input (NAMUR Sensor \/ Mechanical Switch)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003e21 \/ 22\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eChannel 2 Input (NAMUR Sensor \/ Mechanical Switch)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003e51 \/ 52 \/ 53\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eChannel 1 Relay Output (NC \/ COM \/ NO)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003e61 \/ 62 \/ 63\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eChannel 2 Relay Output (NC \/ COM \/ NO)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003e91 \/ 92\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePower Supply (19.2 to 31.2 V DC: + \/ -)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe ACT20X-HDI-SDO-S is part of Weidmuller's premium ACT20X signal converter family. It serves as a direct replacement or upgrade path for legacy ACT20 series modules. When migrating from older systems, verify that your configuration files are updated in the FDT\/DTM frame to match the specific firmware revision of the 8965360000 module.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen utilizing standard mechanical switches instead of NAMUR sensors, the Line Fault Detection (LFD) circuit must be configured correctly. If LFD is enabled without external resistors, the module will interpret an open switch as a wire break and a closed switch as a short circuit. To prevent false diagnostics, either disable LFD via the DTM software or wire a resistor network (typically 1k Ohm in series and 10k Ohm in parallel) directly at the switch contacts.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eConfiguration is performed using the Weidmuller WI-Manager software via the front-panel service jack. Ensure the CBX200 USB interface cable is used for connection. For field wiring, maintain a minimum physical separation of 50 mm between the intrinsically safe (Ex i) blue terminals on the left side and the non-intrinsically safe terminals on the right side to comply with international hazardous area installation standards.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eDe-energize all power sources before mounting, wiring, or configuring the device. Failure to isolate power can result in electrical shock or spark generation in hazardous areas, compromising explosion protection safety.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eSnap the module vertically onto a standard TS 35 DIN rail, ensuring the metal grounding spring on the back makes secure contact with the rail.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eConnect the intrinsically safe field sensors to the blue terminals (11\/12 and 21\/22), ensuring proper cable routing away from power lines.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eWire the relay outputs and the 24 V DC power supply to the black terminals on the opposite side of the module.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eConnect the configuration interface to set the desired input\/output logic and LFD parameters using the FDT\/DTM software before commissioning.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102125252971,"sku":"8965360000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8965360000-ghbv2hkqdq2.png?v=1776137152","url":"https:\/\/www.plcprotech.com\/de\/products\/weidmuller-8965360000-act20x-hdi-sdo-s-isolating-switch-amplifier","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}