{"product_id":"weidmuller-8965460000-act20x-2sai-2hao-s-act20x-series-current-output-isolator","title":"Weidmuller 8965460000 ACT20X-2SAI-2HAO-S ACT20X Series Current Output Isolator","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nOperating as an essential barrier in hazardous process environments, the Weidmuller 8965460000 ACT20X-2SAI-2HAO-S provides high-integrity galvanic isolation and signal conversion for analog current loops. This dual-channel module isolates and converts standard current signals, ensuring safe and precise transmission between field devices in explosive atmospheres and safe-area control systems. Configured via standard \u003cstrong\u003eFDT\/DTM software\u003c\/strong\u003e, it delivers an exceptional accuracy of \u003cstrong\u003eless than 0.1% of span\u003c\/strong\u003e and a rapid step response time of \u003cstrong\u003e5 milliseconds or less\u003c\/strong\u003e, making it highly suitable for critical control loops.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eDual-channel isolation (2SAI-2HAO) for space-saving DIN-rail density.\u003c\/li\u003e\n  \u003cli\u003eComprehensive diagnostic alarm functions for signal limit violations, input line interruptions, power loss, and internal device errors.\u003c\/li\u003e\n  \u003cli\u003eIntegrated alarm relay output supporting nominal switching voltages up to 125V AC or 110V DC.\u003c\/li\u003e\n  \u003cli\u003eSoftware-driven parameterization using FDT\/DTM frameworks for precise calibration and monitoring.\u003c\/li\u003e\n  \u003cli\u003eRobust IP20 housing with secure screw connection terminals for reliable field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eIntrinsically safe signal isolation in chemical and petrochemical processing plants.\u003c\/li\u003e\n  \u003cli\u003eField instrument coupling in oil and gas extraction and refining facilities.\u003c\/li\u003e\n  \u003cli\u003eAnalog signal conditioning in municipal water and wastewater treatment systems.\u003c\/li\u003e\n  \u003cli\u003eDistributed Control System (DCS) and PLC analog I\/O protection in heavy manufacturing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eArticle Number \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e8965460000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eACT20X-2SAI-2HAO-S\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSupply Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e19.2...31.2 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e\u0026lt;= 1.8 W\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eMeasurement Accuracy\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e\u0026lt; 0.1% of span\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eStep Response Time\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e\u0026lt;= 5 ms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTemperature Coefficient\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e\u0026lt; 0.01% of span \/ degC (TU)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eAlarm Relay Output\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSignal limit exceeded, Line interruption, Supply failure, Device error\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNominal Switching Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e\u0026lt;= 125 V AC \/ 110 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eContinuous Current Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e\u0026lt;= 0.5 A AC \/ 0.3 A DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eConnection Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eScrew connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProtection Class\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0...95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0.212 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1.300 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e117.2 mm x 22.5 mm x 113.6 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe ACT20X-2SAI-2HAO-S is a direct fit for applications requiring dual-channel analog isolation with intrinsic safety ratings. When upgrading older ACT20M or non-Ex isolators, verify that the DIN rail spacing accommodates the 22.5 mm width of this module. Ensure that the latest Weidmuller DTM library is installed in your FDT frame application (such as WI-Manager) to recognize the firmware revision of this device.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nWhen installing multiple ACT20X modules side-by-side in high-density control enclosures, calculate the cumulative thermal load. Each module dissipates up to 1.8W under full load. Maintain a minimum clearance or ensure active panel ventilation if ambient temperatures inside the cabinet regularly exceed 50 degC. Note that while the integrated alarm relay is rated for 125V AC, inductive loads must be equipped with external flyback diodes or RC snubbers to prevent contact welding.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nConfiguration must be performed using the dedicated Weidmuller interface cable connected to the front-panel service port. To prevent ground loops and potential damage to your configuration PC, do not connect field-side wiring while the USB configuration cable is active. Always ensure that the field-side intrinsically safe wiring is physically segregated from non-intrinsically safe wiring in compliance with local electrical codes (e.g., NEC Article 504 or EN 60079-14).\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    De-energize all power sources before mounting, wiring, or configuring this device. Verify that no explosive atmospheres are present before opening the enclosure or connecting configuration interfaces. Failure to follow intrinsically safe installation protocols can result in electrical discharge, equipment destruction, or catastrophic ignition in hazardous areas.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 2px;\"\u003e\n      Snap the module securely onto a standard TS 35 DIN rail. Ensure the metal rail-clip on the back of the module makes solid contact with the grounded DIN rail.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 2px;\"\u003e\n      Connect the 24V DC power supply to the designated terminals, observing correct polarity (19.2...31.2 V DC range).\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 2px;\"\u003e\n      Wire the intrinsically safe field inputs and safe-area outputs to the screw terminals according to the system schematic, ensuring correct torque is applied to the terminal screws.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 2px;\"\u003e\n      Connect the configuration interface to parameterize the alarm thresholds, input ranges, and fault-state behaviors using the FDT\/DTM software.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102127972715,"sku":"8965460000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8965460000-x5jbdgn4gcf.png?v=1776137164","url":"https:\/\/www.plcprotech.com\/de\/products\/weidmuller-8965460000-act20x-2sai-2hao-s-act20x-series-current-output-isolator","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}