{"product_id":"abb-s202m-k2uc-2cds272061r0277-s200muc-miniature-circuit-breaker","title":"ABB S202M-K2UC 2CDS272061R0277 S200MUC Miniature Circuit Breaker","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eS202M-K2UC\u003c\/strong\u003e universal current configuration with Product ID \u003cstrong\u003e2CDS272061R0277\u003c\/strong\u003e is a 2-pole \u003cstrong\u003eminiature circuit breaker\u003c\/strong\u003e engineered to provide flexible overcurrent protection and short-circuit fault mitigation in both alternating current (AC) and high-voltage direct current (DC) industrial networks. As a modular component of the \u003cstrong\u003eSystem pro M compact\u003c\/strong\u003e \u003cstrong\u003eS200MUC\u003c\/strong\u003e series, this device incorporates a delayed thermal tripping mechanism for overload safety alongside an electromechanical magnetic tripping mechanism tailored for instantaneous short-circuit protection. It operates across a wide performance range with a certified breaking capacity up to 10 kA at 440 V AC\/DC, making it highly compatible with specialized electrical infrastructure layout panels, field distribution systems, and global industrial automation backup assemblies.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutfitted with a 2-pole hardware matrix ensuring reliable multi-line overcurrent protection and circuit isolation.\u003c\/li\u003e\n\u003cli\u003eUtilizes a flexible universal current configuration certified for execution across both AC and DC wiring topologies.\u003c\/li\u003e\n\u003cli\u003eDesigned with a K-characteristic tripping curve optimized to mitigate specific inductive current spikes and fault profiles.\u003c\/li\u003e\n\u003cli\u003eEmploys a failsafe bi-directional cylinder-lift terminal configuration to guarantee secure, vibration-resistant cable clamping.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-voltage direct current distribution setups, transportation infrastructure, and photovoltaic branch panel assemblies.\u003c\/li\u003e\n\u003cli\u003eMulti-axis industrial automation systems, heavy-duty motor control panels, and field machinery control loops.\u003c\/li\u003e\n\u003cli\u003eComplex low-voltage networks requiring high short-circuit breaking thresholds and multi-standard component flexibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtended Product Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS202M-K2UC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS272061R0277\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614433146\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtended Product Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS202M-K2UC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS272061R0277\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Protected Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTripping Characteristic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eacc. to IEC 60898-1 400 V AC \/ acc. to IEC 60947-2 440 V AC \/ acc. to IEC 60947-2 440 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Frequency (f)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz \/ DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.56 W (1.78 W per Pole at Rated Operating Conditions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eacc. to IEC\/EN 60664-1 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kV (5 kV at 2000 m \/ 6.2 kV at Sea Level)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Ultimate Short-Circuit Breaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(220 V DC) 25 kA \/ (230 V AC) 15 kA \/ (400 V AC) 15 kA \/ (440 V AC) 10 kA \/ (440 V DC) 10 kA \/ (230 V) 10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Service Short-Circuit Breaking Capacity (Ics)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(220 V DC) 20 kA \/ (230 V AC) 10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Short-Circuit Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(AC) 10 kA \/ (230 V AC) 10 kA \/ (400 V AC) 10 kA \/ (230 V) 10 kA \/ (400 V) 10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Conditional Short-Circuit Current (Inc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(230 V) 15 kA \/ (400 V) 15 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnergy Limiting Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Position Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed ON \/ Green OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Endurance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20000 cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulation Group I, RAL 7035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActuator Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulation Group II, Black, Sealable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActuator Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActuator Marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScrew Terminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFailsafe Bi-directional Cylinder-lift Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.8 N-m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Screw Driver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePozidriv 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnecting Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBusbar 10\/10 mm² \/ Flexible with Ferrule 0.75 ... 25 mm² \/ Flexible 0.75 ... 25 mm² \/ Rigid 0.75 ... 35 mm² \/ Stranded 0.75 ... 35 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eacc. to DIN 43880 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Air Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation -25 ... +55 degC \/ Storage -40 ... +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (Enclosure with Cover IP40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28 cycles with 55 degC \/ 90-96% and 25 degC \/ 95-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistance to Vibrations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistance to Shock acc. to IEC 60068-2-27\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25g 2 shocks 13 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Voltage UL\/CSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V DC \/ 480Y\/277 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupting Rating acc. to UL1077\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(220 V AC) 10 kA \/ (277 V AC) 6 kA \/ (440 V DC) 10 kA \/ (480Y\/277 V AC) 10 kA \/ (500 V DC) 10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnecting Capacity UL\/CSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBusbar 14-8 AWG \/ Conductor 14-4 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening Torque UL\/CSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 in-lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e88 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Depth \/ Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.234 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Installation:\u003c\/strong\u003e Mount the hardware securely onto a standard symmetrical tracking option, such as TH35-15 or TH35-7.5 mounting rails in accordance with the IEC 60715 standard layout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrientation Versatility:\u003c\/strong\u003e Designed to be mechanically seated at any functional structural mounting position inside the automation control cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePolarity Enforcement:\u003c\/strong\u003e Ensure careful inspection and execution of the terminal wiring connections relative to the marked polarity designations for direct current operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTorque Specifications:\u003c\/strong\u003e Use a standard Pozidriv 2 screwdriver tool to verify that all cylinder-lift terminal screws are anchored securely to a recommended value of 2.8 N-m (25 in-lb for UL\/CSA arrangements).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeclaration of Conformity - CE:\u003c\/strong\u003e 2CDK400583D2704\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification Agencies:\u003c\/strong\u003e CSA, EN, IEC, UL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC\/EN 60947-2, UL 1077, CSA 22.2 No. 235\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53456045932907,"sku":"S202M-K2UC 2CDS272061R0277","price":1.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/S200MUC2CDS272061R0277_2.jpg?v=1783127042","url":"https:\/\/www.plcprotech.com\/es\/products\/abb-s202m-k2uc-2cds272061r0277-s200muc-miniature-circuit-breaker","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}