{"product_id":"foxboro-fbm202-p0916ac-thermocouple-mv-input-module","title":"Foxboro FBM202 P0916AC Thermocouple\/mV Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFoxboro FBM202 P0916AC\u003c\/strong\u003e is a DIN rail-mounted passive termination assembly designed to interface eight isolated thermocouple\/mV analog input signals with an \u003cstrong\u003eFBM202\u003c\/strong\u003e module within the \u003cstrong\u003eFoxboro I\/A Series\u003c\/strong\u003e and \u003cstrong\u003eFoxboro Evo\u003c\/strong\u003e DCS platforms. The \u003cstrong\u003eP0916AC\u003c\/strong\u003e termination assembly incorporates a 4-wire 100 ohm platinum RTD (IEC 751, Class B) to provide cold-junction reference temperature compensation for accurate thermocouple measurements. Each input channel on the associated \u003cstrong\u003eFBM202\u003c\/strong\u003e module provides galvanic isolation from other channels and ground, supporting standard thermocouple types B, E, J, K, N, R, S, T, and millivolt input signals. Signal processing involves per-channel Sigma-Delta A\/D conversion, upscale thermocouple burnout detection, and configurable integration periods. The \u003cstrong\u003eP0916AC\u003c\/strong\u003e termination assembly connects to the baseplate-mounted \u003cstrong\u003eFBM202\u003c\/strong\u003e module via a removable Type 2 termination cable, conveying field signals to the module and communicating via the redundant 2 Mbps module Fieldbus to Fieldbus Communication Modules or Control Processors.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEight-channel field I\/O feedthrough connection with channel-to-channel galvanic isolation\u003c\/li\u003e\n\u003cli\u003eIntegrated 4-wire 100 ohm platinum RTD (IEC 751, Class B) for reference junction compensation\u003c\/li\u003e\n\u003cli\u003eCompression screw terminal connections accepting 0.2 to 4 mm2 (24 to 12 AWG) field wiring\u003c\/li\u003e\n\u003cli\u003ePolyvinyl chloride (PVC) housing construction rated for -20 to +50 degC operating temperatures\u003c\/li\u003e\n\u003cli\u003ePassive feedthrough interface supporting Type 2 termination cables up to 30 m in length\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting design compatible with 32 mm and 35 mm DIN rails\u003c\/li\u003e\n\u003cli\u003eHigh-accuracy performance utilizing per-channel Sigma-Delta A\/D conversion on the FBM202\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThermocouple signal interfacing for DCS temperature loops\u003c\/li\u003e\n\u003cli\u003eProcess temperature monitoring with cold junction compensation\u003c\/li\u003e\n\u003cli\u003eMillivolt input processing for industrial automation systems\u003c\/li\u003e\n\u003cli\u003eReplacement and upgrade of Foxboro 100 Series FBM02 field wiring setups\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eP0916AC\u003c\/td\u003e\n\u003ctd\u003eEight-channel thermocouple\/mV passive feedthrough TA with RTD\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003ctd\u003eCompression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP0916AD\u003c\/td\u003e\n\u003ctd\u003eEight-channel thermocouple\/mV passive feedthrough TA with RTD\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003ctd\u003eRing Lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP0916XH\u003c\/td\u003e\n\u003ctd\u003eEight-channel thermocouple\/mV passive feedthrough TA with RTD\u003c\/td\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003ctd\u003eCompression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP0917JL\u003c\/td\u003e\n\u003ctd\u003eEight-channel thermocouple\/mV passive feedthrough TA with RTD\u003c\/td\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003ctd\u003eRing Lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP0928CN\u003c\/td\u003e\n\u003ctd\u003eBaseplate-mounted TA for two sets of eight thermocouple\/mV channels\u003c\/td\u003e\n\u003ctd\u003ePC\/ABS\u003c\/td\u003e\n\u003ctd\u003eCompression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter \/ Value\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eFoxboro by Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eP0916AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCompatible Module\u003c\/td\u003e\n\u003ctd\u003eFBM202 (P0926EQ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8 isolated thermocouple\/mV input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e-10.5 to +69.5 mV dc (0 to 64000 raw counts); Full range: 71.419 mV (65535 raw counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eThermocouple Types\u003c\/td\u003e\n\u003ctd\u003eB, E, J, K, N, R, S, T and other millivolt signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDifferential Input Impedance\u003c\/td\u003e\n\u003ctd\u003e10 Mohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eBurnout Detection\u003c\/td\u003e\n\u003ctd\u003eFull upscale value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCommon Mode Voltage\u003c\/td\u003e\n\u003ctd\u003eUp to 30 V ac or 60 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy \u0026amp; Performance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMillivolt Input Accuracy\u003c\/td\u003e\n\u003ctd\u003e+0.03% of span (+-27 uV) at 25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRTD Channel Accuracy\u003c\/td\u003e\n\u003ctd\u003e+0.03% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRTD Reference Junction Conformity\u003c\/td\u003e\n\u003ctd\u003e+-0.25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eThermocouple Conformity\u003c\/td\u003e\n\u003ctd\u003e+0.25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAccuracy Temperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e+-50 ppm\/degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRTD Reference Junction Measurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e+-0.50 degC (using RTD internal to Foxboro TAs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eReference Junction Type\u003c\/td\u003e\n\u003ctd\u003e4-wire 100 ohm platinum RTD (IEC 751, Class B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation per channel; withstands 600 V ac for 1 minute between channel and ground or channel to channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating Temperature (PVC TA)\u003c\/td\u003e\n\u003ctd\u003e-20 to +50 degC (-4 to +122 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 degC (-40 to +158 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e-300 to +3,000 m (-1,000 to +10,000 ft) operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eContamination\u003c\/td\u003e\n\u003ctd\u003eClass G3 (Harsh) per ISA Standard S71.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTA Material\u003c\/td\u003e\n\u003ctd\u003ePolyvinyl Chloride (PVC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTermination Type\u003c\/td\u003e\n\u003ctd\u003eCompression screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCompression Accepted Wiring Sizes\u003c\/td\u003e\n\u003ctd\u003eSolid\/Stranded: 0.2 to 4 mm2 \/ 24 to 12 AWG; Stranded with Ferrules: 0.2 to 2.5 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eWeight (Compression TA)\u003c\/td\u003e\n\u003ctd\u003e159 g (0.35 lb) approximate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDimensions (Compression TA)\u003c\/td\u003e\n\u003ctd\u003e125 mm x 76 mm x 72 mm (4.93 in x 2.99 in x 2.83 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin \/ Terminal\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Termination Compression Screw\u003c\/td\u003e\n\u003ctd\u003eDirect connection for 8 two-wire thermocouple\/mV analog input field signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal RTD Connection\u003c\/td\u003e\n\u003ctd\u003eConnections to the integral 4-wire 100 ohm platinum RTD for reference junction compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Interface\u003c\/td\u003e\n\u003ctd\u003e25-pin D-subminiature connector linking to the FBM baseplate via Type 2 cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting\u003c\/strong\u003e: Mount the P0916AC termination assembly on standard 32 mm or 35 mm DIN rails.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Connection\u003c\/strong\u003e: Connect the 25-pin D-subminiature end of the Type 2 termination cable to the TA and the 37-pin D-subminiature end to the FBM202 baseplate slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring\u003c\/strong\u003e: Insert field wiring into compression screw terminals accepting 0.2 to 4 mm2 (24 to 12 AWG) solid or stranded conductors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Limits\u003c\/strong\u003e: Ensure field wiring voltages do not exceed 30 V ac or 60 V dc to prevent electrical safety code violations and shock hazards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Enclosure\u003c\/strong\u003e: Install in appropriate enclosures when operating in Class G3 harsh environments to comply with environmental ratings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL\/UL-C\u003c\/strong\u003e: UL\/UL-C listed as suitable for use in Class I, Groups A-D, Division 2, temperature code T4 hazardous locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX \/ CENELEC\u003c\/strong\u003e: CENELEC (DEMKO) certified EEx nA IIC T4 for use in Zone 2 potentially explosive atmospheres.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":53689170100587,"sku":"FBM202","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/FBM202-P0916AC_001_1200x1200_b36887fb-5338-410b-95dd-8dd68e015420.jpg?v=1786230560","url":"https:\/\/www.plcprotech.com\/es\/products\/foxboro-fbm202-p0916ac-thermocouple-mv-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}