{"product_id":"foxboro-p0914sv-fbm203-platinum-nickel-copper-rtd-input-module","title":"Foxboro P0914SV FBM203 Platinum\/Nickel\/Copper RTD Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFoxboro P0914SV FBM203\u003c\/strong\u003e is an eight-channel resistance temperature detector (RTD) input module designed for process automation systems. The \u003cstrong\u003eP0914SV\u003c\/strong\u003e accepts 2- or 3-wire RTD sensor inputs within a resistance range of 0 to 320 ohms. Each analog input channel is galvanically isolated from ground and all other channels. The module performs signal conversions to interface electrical input signals from field sensors to a redundant 2 Mbps module fieldbus, executing an analog input application program that provides conversion timing and configurable options for Rate of Change Limits.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEight galvanically isolated RTD input channels\u003c\/li\u003e\n\u003cli\u003eHigh accuracy achieved by sigma-delta data conversions for each channel\u003c\/li\u003e\n\u003cli\u003eCompact, rugged design suitable for ISA S71.04 Class G3 harsh environments\u003c\/li\u003e\n\u003cli\u003eExecution of analog input application program with configurable Rate of Change Limits\u003c\/li\u003e\n\u003cli\u003eSupport for DIN rail mounted or baseplate-mounted passive termination assemblies\u003c\/li\u003e\n\u003cli\u003eHot-swappable module replacement without disturbing field wiring, power, or communication cabling\u003c\/li\u003e\n\u003cli\u003eFront-panel LEDs for operational status indications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProcess temperature monitoring using Platinum or Nickel RTD sensors\u003c\/li\u003e\n\u003cli\u003eIndustrial temperature measurement in Foxboro Evo Control Core Services systems\u003c\/li\u003e\n\u003cli\u003eLegacy 100 Series FBM system upgrades and replacements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eFoxboro by Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eP0914SV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFBM203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 isolated RTD channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e0 to 320 ohms (320 ohms = 64000 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Current\u003c\/td\u003e\n\u003ctd\u003e0.19 mA dc nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead Resistance\u003c\/td\u003e\n\u003ctd\u003e50 ohms maximum per lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03% of span (includes linearity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e±50 ppm\/degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegration Period\u003c\/td\u003e\n\u003ctd\u003eSoftware configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;125 dB at 50 or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;95 dB at 50 or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Isolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation per channel, 600 V ac for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e24 V dc +5%, -10% (Redundant input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e3 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Weight\u003c\/td\u003e\n\u003ctd\u003e284 g approximate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e102 mm x 45 mm x 104 mm (114 mm height including mounting lugs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e-300 to +3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Rating\u003c\/td\u003e\n\u003ctd\u003eClass G3 (Harsh) per ISA Standard S71.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e The module mounts directly onto a DIN rail mounted Modular Baseplate (4-slot or 8-slot) or a 100 Series conversion mounting structure. Baseplates can be installed horizontally or vertically on a DIN rail, or horizontally in a 19-inch rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Replacement:\u003c\/strong\u003e Designed for removal and replacement without taking down field device wiring, power supply, or fieldbus communication cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Field I\/O signals connect through dedicated DIN rail mounted or baseplate-mounted Termination Assemblies (TAs) using compression screw or ring lug terminals via removable termination cables up to 30 meters in length.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e European EMC Directive 89\/336\/EEC (EN 50081-2, EN 50082-2, EN 61326 Annex A, CISPR 11 Class A, IEC 61000-4-2\/3\/4\/5\/6\/8)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Safety:\u003c\/strong\u003e UL\/UL-C listed for Class I, Groups A-D; Division 2; temperature code T4.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e CENELEC (DEMKO) certified EEx nA [NL] IIC T4 for Zone 2 explosive atmospheres.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":53689182585195,"sku":"P0914SV FBM203","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/P0914SV-FBM203_001_1200x1200_7f143d3e-b044-4c65-b970-59fba642a53a.jpg?v=1786230993","url":"https:\/\/www.plcprotech.com\/es\/products\/foxboro-p0914sv-fbm203-platinum-nickel-copper-rtd-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}