{"product_id":"abb-pm866k02-3bse050199r1-ac-800m-redundant-processor-units","title":"ABB PM866K02 3BSE050199R1 AC 800M Redundant Processor Units","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003ePM866K02\u003c\/strong\u003e \u003cstrong\u003e3BSE050199R1\u003c\/strong\u003e is a redundant processor unit kit configured for the \u003cstrong\u003eAC 800M\u003c\/strong\u003e control system platform, designed to deliver high availability and fault-tolerant process control. Equipped with a microprocessor operating at a clock frequency of 133 MHz and supported by 64 MB of RAM, this system component handles execution of complex control logic, diagnostics, and simultaneous communication tasks. The assembly natively interfaces with up to 12 S800 I\/O units via its electrical ModuleBus and includes four onboard communication ports supporting dual Ethernet (CN1, CN2) and serial (COM3, COM4) connections. The packaged kit provides two \u003cstrong\u003ePM866K01\u003c\/strong\u003e processor units alongside a \u003cstrong\u003eTK850\u003c\/strong\u003e CEX-bus expansion cable and a \u003cstrong\u003eTK851\u003c\/strong\u003e RCU-Link cable, facilitating precise module synchronization and communication bus expansion within the 800xA and Compact Product Suite infrastructures.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMicroprocessor execution driven by an MPC866 processor running at a clock frequency of 133 MHz.\u003c\/li\u003e\n\u003cli\u003eVolatile memory management utilizing 64 MB SDRAM paired with 4 MB flash PROM for firmware residency.\u003c\/li\u003e\n\u003cli\u003eComprehensive onboard interface allocation featuring dual Ethernet channels and dedicated serial links with modem support.\u003c\/li\u003e\n\u003cli\u003eDirect local I\/O handling supporting up to 12 S800 I\/O units connected to the electrical ModuleBus.\u003c\/li\u003e\n\u003cli\u003eDedicated Redundancy Control Link enabling structural synchronization between parallel processor units.\u003c\/li\u003e\n\u003cli\u003eIntegrated Compact Flash interface supporting runtime application loading and cold retain data storage operations.\u003c\/li\u003e\n\u003cli\u003eBuilt-in internal 5ms power reservoir ensuring ordered and controlled CPU power-down cycles during supply disruptions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed Control Systems (DCS) requiring process redundancy within 800xA automation setups.\u003c\/li\u003e\n\u003cli\u003eCritical path control infrastructure across manufacturing, power generation, and process refining fields.\u003c\/li\u003e\n\u003cli\u003eHigh-availability operations utilizing Compact Product Suite architectures and S800 remote I\/O configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE050199R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eABB Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePM866K02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePM866K02 Redundant Processor Units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 pcs PM866K01 Processor unit\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e1 pc TK850 CEX-bus expansion cable\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e1 pc TK851 RCU-Link cable\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLicense Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo license included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE050199R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eABB Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePM866K02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCPU Clock Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e133 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 MB flash PROM, 64 MB SDRAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Power Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.1 W (8.6 W typical including full supply to ModuleBus and CEX-Bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mA typical (360 mA max. excluding ModuleBus and CEX-Bus supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Input Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-pin screw connector (L+, L-, SA, SB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V nominal (19.2 V DC to 30 V DC range at L+ and L-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundant Status Voltage Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 V (SA, SB inputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundant Status High Level Min\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 V (SA, SB inputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundant Status Low Level Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 V (SA, SB inputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Backup\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal or external battery unit (SB821 or SB822)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 according to EN60529, IEC 529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e119 mm x 186 mm x 135 mm (4.7 in x 7.3 in x 5.3 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChina (CN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85389091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector \/ Port\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eL+ \/ L-\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC Nominal Power Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSA \/ SB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRedundant Power Supply Status Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCN1 \/ CN2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEthernet Ports (IEEE 802.3, 10BaseT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOM3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial Port (RS-232C) with Modem Support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOM4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial Port (RS-232C) for Service Tool Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModuleBus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrical connection port for up to 12 S800 I\/O units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRCU-Link\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection port for Redundancy Control Link cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCEX-Bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommunication Exchange Bus expansion interface via TK850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompact Flash Slot\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInterface for application loading and cold retain storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Orientation:\u003c\/strong\u003e Mount the assembly horizontally along the DIN rail, ensuring the vertical height allows lock mechanism clearance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Coupling:\u003c\/strong\u003e Interconnect the twin processors using the included TK851 RCU-Link cable to initialize the synchronization channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCEX-Bus Interfacing:\u003c\/strong\u003e Utilize the supplied TK850 expansion cable to attach additional communication modules along the side terminal paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Configuration:\u003c\/strong\u003e Secure connections using the 4-pin screw terminal block, ensuring standard polarity match for L+ and L- paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Monitoring Terminal:\u003c\/strong\u003e Wire supply monitoring relays to the SA and SB ports, observing logical threshold limits (High over 15 V, Low under 8 V).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Allow sufficient convective clearance within the IP20 enclosure to maintain operation within nominal thermal boundaries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory Preservation:\u003c\/strong\u003e Insert either an internal or external battery unit (SB821 or SB822) to retain runtime RAM definitions during complete power failures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTÜV (Technical Inspection Association)\u003c\/li\u003e\n\u003cli\u003eUL standards\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53504132383083,"sku":"PM866K02 3BSE050199R1","price":20000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/PM866K02_3BSE050199R1jpg.jpg?v=1783665512","url":"https:\/\/www.plcprotech.com\/fa\/products\/abb-pm866k02-3bse050199r1-ac-800m-redundant-processor-units","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}