{"product_id":"abb-s200-rpa-490176212-advant-s200-i-o-repeater-adapter-module","title":"ABB S200-RPA 490176212 Advant S200 I\/O Repeater Adapter Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eServing as a fundamental power distribution and communication interface, the \u003cstrong\u003eABB S200-RPA\u003c\/strong\u003e manages backplane voltage and signal translation within distributed \u003cstrong\u003eAdvant S200 I\/O\u003c\/strong\u003e architectures. This high-efficiency interface module accepts an external \u003cstrong\u003e24V DC\u003c\/strong\u003e (Class 2) input supply and converts it to a clean, regulated \u003cstrong\u003e5V DC\u003c\/strong\u003e output rated at \u003cstrong\u003e1.6A\u003c\/strong\u003e to drive the internal logic of connected downstream I\/O modules. Simultaneously acting as an active signal repeater, the S200-RPA ensures signal integrity across extended physical distances and multi-node clusters on the local S200 I\/O bus, maintaining deterministic communication even in electrically challenging industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eDual-Function Topology:\u003c\/strong\u003e Combines active logic-level signal repeating with integrated 24V to 5V DC step-down power regulation.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eRegulated Backplane Output:\u003c\/strong\u003e Delivers a highly stable 5V DC supply at up to 1.6A to drive internal communication circuits.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eClass 2 Circuit Compatibility:\u003c\/strong\u003e Rated for a maximum input capacity of 24V DC at 7A, aligning with standard safety and power-limiting requirements.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e Provides robust isolation to protect downstream distributed I\/O modules from input-side voltage transients.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eDIN-Rail Mounting:\u003c\/strong\u003e Designed for rapid, standardized installation into high-density control cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eAdvant OCS (Open Control System) distributed I\/O architectures.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003ePower segmentation and bus expansion in complex, multi-rack S200 I\/O configurations.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eHeavy industrial automation environments requiring high noise immunity and isolation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold; color: #1a365d;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold; color: #1a365d;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eABB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eS200-RPA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eArticle Number \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e490176212\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eAdvant S200 I\/O\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePrimary Input Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e24V DC (Class 2 compatible)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eMaximum Input Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e7A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eBackplane Output Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e5V DC (regulated)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eMaximum Output Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1.6A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePhase-Out (Legacy \/ Spare Parts Support Active)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0.62 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCommodity Code (HS Code)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAs the Advant S200 I\/O system is currently in its Phase-Out stage, sourcing exact-match hardware like the S200-RPA (490176212) is vital for keeping legacy control networks running without rewriting system configurations. This module functions as a critical bridge. When configuring system hardware, always ensure compatibility with downstream processing modules (e.g., the AC input module S200-IA8) to prevent firmware and communication protocol discrepancies on the S200 I\/O bus.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eA common issue in larger distributed clusters is overloading the 5V DC bus. While the S200-RPA can handle up to 7A on the 24V DC input side, its regulated backplane logic output is strictly capped at 1.6A. Before commissioning, calculate the combined current draw of all downstream modules connected to the same bus segment. If the cumulative consumption exceeds 1.6A, you must break the segment and add a second S200-RPA to boost and isolate the backplane logic supply.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo guarantee optimal performance and shield the signal bus from electromagnetic interference (EMI), ensure that the DIN rail itself is connected to a low-impedance functional earth. The integrated shield grounding spring on the rear of the S200-RPA relies on direct, clean contact with an unpainted DIN rail. When wiring the primary 24V DC input, always employ an isolated Class 2 power supply to remain within safety certifications and protect internal components from source transients.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e De-energize all primary 24V DC power supply lines before attempting installation, mounting, or wiring of this equipment. Do not hot-swap or insert\/remove this adapter module under electrical load, as doing so can trigger immediate communication failures or damage internal logic circuits.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; min-width: 2rem; height: 2rem; border-radius: 50%; font-weight: bold;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.2rem;\"\u003e\n      \u003cstrong\u003eMounting onto DIN Rail:\u003c\/strong\u003e Securely snap the S200-RPA module onto a grounded, unpainted standard DIN rail, verifying that the rear grounding contacts are firmly engaged.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; min-width: 2rem; height: 2rem; border-radius: 50%; font-weight: bold;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.2rem;\"\u003e\n      \u003cstrong\u003eWire the 24V DC Supply:\u003c\/strong\u003e Connect the positive and negative leads of a verified Class 2 24V DC supply to the input power terminals. Ensure the wires are securely tightened to avoid localized thermal hotspots.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; min-width: 2rem; height: 2rem; border-radius: 50%; font-weight: bold;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.2rem;\"\u003e\n      \u003cstrong\u003eAssemble Downstream Modules:\u003c\/strong\u003e Physically slide the adjacent Advant S200 I\/O modules into position onto the right-hand bus interface. Secure all locking mechanisms before applying power.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701956702571,"sku":"S200-RPA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/s200-rpa-ec0e3akpgrb_f40fbd53-009e-459c-a5fc-c51575b292fa.jpg?v=1766478098","url":"https:\/\/www.plcprotech.com\/fa\/products\/abb-s200-rpa-490176212-advant-s200-i-o-repeater-adapter-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}