{"product_id":"beckhoff-el3413-0001-ethercat-terminal-3-channel-power-measurement-module","title":"BECKHOFF EL3413-0001 EtherCAT Terminal 3-Channel Power Measurement Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for precise utility-grade analysis, the \u003cstrong\u003eEL3413-0001\u003c\/strong\u003e functions as a highly integrated \u003cstrong\u003e3-channel power measurement terminal\u003c\/strong\u003e within the Beckhoff EtherCAT I\/O system. This industrial-grade module enables comprehensive evaluation of 3-phase AC power grids by direct connection of voltages up to 690 V AC. It features galvanically isolated current inputs designed for adjustable ranges of 100 mA, 1 A, and 5 A, providing high-accuracy readings even in electrically noisy environments.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eEL3413-0001\u003c\/strong\u003e power measurement terminal performs mains-synchronous conversion with a 16-bit resolution, calculating essential network parameters such as active, reactive, and apparent power, energy consumption, frequency, power factor (cos phi), and harmonic wave analysis. It is optimized for energy management systems, grid synchronization, and machine-level load monitoring, transferring all calculated values directly to the PLC or DCS via high-speed EtherCAT communication.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect 3-phase power measurement for alternating voltages up to 690 V AC.\u003c\/li\u003e\n  \u003cli\u003eGalvanically isolated current inputs with adjustable ranges (100 mA, 1 A, 5 A) for potential-free installation.\u003c\/li\u003e\n  \u003cli\u003eComprehensive data calculation including voltage, current, active\/reactive\/apparent power, energy, frequency, and harmonic waves.\u003c\/li\u003e\n  \u003cli\u003eHigh-speed mains-synchronous conversion with 16-bit resolution.\u003c\/li\u003e\n  \u003cli\u003eHigh electrical isolation of 4500 V for robust system protection.\u003c\/li\u003e\n  \u003cli\u003eCompact 12 mm terminal housing with integrated diagnostic LEDs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial power monitoring and plant-wide energy management systems.\u003c\/li\u003e\n  \u003cli\u003ePower quality and harmonic analysis in heavy manufacturing environments.\u003c\/li\u003e\n  \u003cli\u003eLoad monitoring and predictive maintenance for large electric motors and drives.\u003c\/li\u003e\n  \u003cli\u003eIntegration with renewable energy systems, wind power, and solar sub-stations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eCategory\u003c\/strong\u003e\n      \u003cstrong\u003eTechnical Parameter\u003c\/strong\u003e\n      \u003cstrong\u003eValue\u003c\/strong\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBeckhoff\u003c\/td\u003e\n      \u003ctd\u003eEL3413-0001\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTechnology\u003c\/td\u003e\n      \u003ctd\u003e3-phase power measurement for alternating voltages\u003c\/td\u003e\n      \u003ctd\u003eSingle-ended\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n      \u003ctd\u003e4 x current, 3 x voltage\u003c\/td\u003e\n      \u003ctd\u003eMains-synchronous\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMeasuring Voltage\u003c\/td\u003e\n      \u003ctd\u003eMax. 690 V AC 3-phase (ULX-N: max. 400 V AC)\u003c\/td\u003e\n      \u003ctd\u003eAdjustable: 100 mA, 1 A (default), 5 A (potential-free)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eResolution\u003c\/td\u003e\n      \u003ctd\u003e1 microampere, 0.1 mV, 10 mW\u003c\/td\u003e\n      \u003ctd\u003e16-bit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMeasuring Error\u003c\/td\u003e\n      \u003ctd\u003e0.5% relative to full scale value (U\/I), 1% calculated value\u003c\/td\u003e\n      \u003ctd\u003e4500 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption (E-bus)\u003c\/td\u003e\n      \u003ctd\u003eTyp. 160 mA\u003c\/td\u003e\n      \u003ctd\u003eIP20 \/ variable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +60 degC\u003c\/td\u003e\n      \u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n      \u003ctd\u003ePolycarbonate\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e12 mm x 100 mm x 68 mm\u003c\/td\u003e\n      \u003ctd\u003eApprox. 100 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnection Type\u003c\/th\u003e\n      \u003cth\u003eConductor Specifications\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWiring Technology\u003c\/td\u003e\n      \u003ctd\u003eSpring actuation by screwdriver\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSolid Conductor (e)\u003c\/td\u003e\n      \u003ctd\u003e0.08 to 2.5 mm² (AWG 28 to 14)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFlexible Conductor (f)\u003c\/td\u003e\n      \u003ctd\u003e0.08 to 2.5 mm² (AWG 28 to 14)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFerrule Connection (a)\u003c\/td\u003e\n      \u003ctd\u003e0.14 to 1.5 mm² (AWG 26 to 16)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStripping Length\u003c\/td\u003e\n      \u003ctd\u003e8 to 9 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Contact Current Load\u003c\/td\u003e\n      \u003ctd\u003eImax: 10 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install directly onto a standard 35 mm DIN rail conforming to EN 60715. Secure using the integrated lock.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSide-by-Side Mounting:\u003c\/strong\u003e Align and connect adjacent terminals using the integrated double slot and key connection system.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use solid, stranded, or ferruled wires. Fully depress the spring tension clamp using a standard flat-head screwdriver before inserting the wire, then release to clamp. Ensure correct stripping length (8 to 9 mm) to prevent exposed copper.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106446991723,"sku":"EL3413-0001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/el3413-0001-ug2tr1zrtdk.png?v=1776244486","url":"https:\/\/www.plcprotech.com\/fa\/products\/beckhoff-el3413-0001-ethercat-terminal-3-channel-power-measurement-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}