{"product_id":"beckhoff-ip2300-b200-fieldbus-box-4-channel-digital-input-4-channel-digital-output-module","title":"BECKHOFF IP2300-B200 Fieldbus Box 4-Channel Digital Input \/ 4-Channel Digital Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDecentralized signal processing directly on machinery is efficiently handled by the \u003cstrong\u003eIP2300-B200\u003c\/strong\u003e digital input\/output fieldbus box. This rugged device integrates four digital inputs and four digital outputs into a compact, robust housing designed for environments where traditional control cabinets are impractical. By using the high-speed \u003cstrong\u003eBeckhoff Lightbus\u003c\/strong\u003e system, the module facilitates rapid and noise-immune communication across distributed setups.\u003c\/p\u003e\n\n\u003cp\u003eThe fieldbus box uses plastic optical fibers (APF) to exchange data, providing optical isolation that prevents electromagnetic interference from disrupting signal integrity. It supports 24 V DC I\/O signals with quick response times and features comprehensive short-circuit protection across all outputs. Standard M8 connection interfaces simplify wiring, making this unit a reliable component for harsh industrial automation zones.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFour 24 V DC digital inputs with 3.0 ms filter time.\u003c\/li\u003e\n  \u003cli\u003eFour 24 V DC digital outputs rated at 0.5 A per channel.\u003c\/li\u003e\n  \u003cli\u003eNoise-immune Lightbus system utilizing 1000 micrometer APF plastic fiber-optic cables.\u003c\/li\u003e\n  \u003cli\u003eInherent resistance to electromagnetic interference due to fiber-optic data transmission.\u003c\/li\u003e\n  \u003cli\u003eDirect machine mounting with a high protection rating of IP65, IP66, or IP67.\u003c\/li\u003e\n  \u003cli\u003eIndividually short-circuit proof outputs with typical 1.5 A short-circuit current limit.\u003c\/li\u003e\n  \u003cli\u003eFeed-through power supply connections via M8 ports for simplified system cabling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized manufacturing automation and assembly lines.\u003c\/li\u003e\n  \u003cli\u003eConveyor and material handling systems requiring localized I\/O control.\u003c\/li\u003e\n  \u003cli\u003eHigh-noise environments such as welding cells or heavy machinery zones.\u003c\/li\u003e\n  \u003cli\u003eProcess plants needing field-level I\/O integration without protective enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP2300-B200\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box (Digital Input\/Output)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLightbus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Transfer Medium\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAPF (plastic) fiber-optic conductor (1000 micrometer)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Transfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.5 Mbaud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBus Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 x fiber-optic socket for plug ZS1020-0010\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDistance Between Stations\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMax. 45 m\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4 inputs + 4 outputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Filter Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.0 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e\"0\" Signal Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-3 to +5 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e\"1\" Signal Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e11 to 30 V (6 mA input current, EN 61131-2, type 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSensor Supply Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMax. 0.5 A total, short-circuit proof (derived from control voltage)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLoad Types Supported\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOhmic, inductive, lamp load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Load Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Output Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.5 A per channel (individually short-circuit proof)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShort-Circuit Current Limit\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003etyp. 1.5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Connections\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFeed: 1 x M8 male socket, 4-pin; Downstream: 1 x M8 female socket, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eControl Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eControl voltage to fieldbus: Yes; Channels to control voltage: No\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration\/Shock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Immunity\/Emission\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePA6 (polyamide)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e30 mm x 210 mm x 26.5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eapprox. 250 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface Type\u003c\/th\u003e\n      \u003cth\u003eConnection Detail\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBus Ports\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 x Fiber-optic sockets\u003c\/td\u003e\n      \u003ctd\u003eLightbus optical ring connection (ZS1020-0010 plug compatibility)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eI\/O Connections\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 x 8 mm snap-type ports\u003c\/td\u003e\n      \u003ctd\u003e4 x digital inputs, 4 x digital outputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Feed\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 male connector, 4-pin\u003c\/td\u003e\n      \u003ctd\u003eMain control voltage and load supply input\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Downstream\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 female connector, 4-pin\u003c\/td\u003e\n      \u003ctd\u003ePower distribution loop to subsequent modules\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the unit directly on a flat machine surface using the two integrated 3.5 mm diameter fixing holes intended for M3 screws.\u003c\/li\u003e\n  \u003cli\u003eObserve minimum bending radii constraints for the APF plastic fiber-optic cables to prevent signal attenuation or damage.\u003c\/li\u003e\n  \u003cli\u003eEnsure all unused M8 and 8 mm snap-type ports are sealed with appropriate protective caps to preserve the IP67 integrity.\u003c\/li\u003e\n  \u003cli\u003eDisconnect the auxiliary power supply before connecting or disconnecting fiber-optic components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106456002923,"sku":"IP2300-B200","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip2300-b200-xva51c54ov0.png?v=1776244983","url":"https:\/\/www.plcprotech.com\/fa\/products\/beckhoff-ip2300-b200-fieldbus-box-4-channel-digital-input-4-channel-digital-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}