{"product_id":"beckhoff-ip5109-b520-fieldbus-box","title":"Beckhoff IP5109-B520 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for decentralized automation architecture, the \u003cstrong\u003eBeckhoff IP5109-B520\u003c\/strong\u003e Fieldbus Box establishes reliable distributed I\/O connection in harsh manufacturing environments. Operating directly on DeviceNet networks, this robust module eliminates the need for protective control cabinets by providing high ingress protection against dust and liquid exposure. The module features integrated intelligence to detect network transmission speeds dynamically and offers extensive diagnostic functions to minimize plant downtime.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eIP5109-B520\u003c\/strong\u003e integrates seamless physical layer interfaces using industry-standard M12 and M8 connections. It facilitates flexible communication types, including bit strobe, polling, cyclic, and change-of-state (COS) messaging, ensuring efficient data distribution to high-level controllers. System engineers can configure the module parameters easily through the Beckhoff KS2000 software suite or directly via explicit messaging from the master controller.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCabinet-Free Installation:\u003c\/strong\u003e Rugged design allows direct machine mounting, optimizing wiring paths and reducing installation footprint.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomatic Baud Rate Detection:\u003c\/strong\u003e Automatically senses and adapts to communication speeds up to 500 kbaud.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e Comprehensive diagnostic LEDs provide local visibility into bus status, supply errors, and operational performance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Communication Protocols:\u003c\/strong\u003e Supports a variety of DeviceNet I\/O communication configurations, including polling, bit strobe, cyclic, and change of state.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Power Isolation:\u003c\/strong\u003e Provides 500 V electrical isolation between control voltage and fieldbus components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAutomotive assembly and robotic welding lines\u003c\/li\u003e\n  \u003cli\u003eMaterial handling and conveyor sortation systems\u003c\/li\u003e\n  \u003cli\u003eMachine tool and manufacturing line integration\u003c\/li\u003e\n  \u003cli\u003eHeavy industrial packaging equipment\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBeckhoff Automation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP5109-B520\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFieldbus Protocol\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDeviceNet\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Transfer Rates\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAutomatic detection up to 500 kbaud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBus Interface Connection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 plug, 5-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransmission Medium\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eShielded copper cable with power supply (typically 2 x 2 x 0.25 mm²)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eControl Voltage Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Connection (Feed)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 male connector, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Connection (Downstream)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 female connector, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInternal Box Supply Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45 mA + sensor consumption (maximum 0.5 A total)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500 V (control voltage \/ fieldbus)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax Station Distance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500 m \/ 250 m \/ 100 m (dependent on baud rate and cable type)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP65 \/ IP66 \/ IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Immunity \/ Emission\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnector \/ Pin\u003c\/th\u003e\n      \u003cth\u003eFunction Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eM12 Bus Pin 1\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eShield (drain wire)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eM12 Bus Pin 2\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eV+ (DeviceNet power supply)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eM12 Bus Pin 3\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eV- (DeviceNet power supply reference)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eM12 Bus Pin 4\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCAN_H\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eM12 Bus Pin 5\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCAN_L\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eM8 Power Supply Feed Pin 1\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eControl Voltage +24 V DC (Us)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eM8 Power Supply Feed Pin 2\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLoad Voltage +24 V DC (Up)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eM8 Power Supply Feed Pin 3\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGNDs (Control Voltage reference)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eM8 Power Supply Feed Pin 4\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGNDp (Load Voltage reference)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Attach the box securely using the integrated mounting flanges on a flat, vibration-free surface. Direct metal contact assists with heat dissipation and structural stability.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure a low-resistance RF grounding connection to the machine chassis via the metallic mounting surfaces or dedicated grounding tabs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCabling Shielding:\u003c\/strong\u003e Use pre-assembled, shielded DeviceNet cabling to prevent electromagnetic interference from surrounding industrial equipment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Sealing:\u003c\/strong\u003e Tighten all M12 and M8 connectors to their specified torque limits. Cover any unused female sockets with IP67-rated protective caps to maintain the integrity of the enclosure seal.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106422874475,"sku":"IP5109-B520","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip5109-b520-ujqfjyzevx4.png?v=1776245109","url":"https:\/\/www.plcprotech.com\/fa\/products\/beckhoff-ip5109-b520-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}