{"product_id":"beckhoff-kl2761-bus-terminal-system-dimmer-module","title":"BECKHOFF KL2761 Bus Terminal System Dimmer Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eRealize stable, fieldbus-controlled power regulation with the \u003cstrong\u003eBeckhoff KL2761\u003c\/strong\u003e 1-channel universal dimmer terminal. Engineered for integration within the standard Beckhoff K-bus terminal assembly, this module regulates the power of lighting devices and other AC loads up to 600 VA. Utilizing automatic load detection, it handles ohmic, inductive, and capacitive loads via advanced phase control mechanisms. This terminal enables precise, system-level brightness and power adjustments directly from the master controller, offering scalable distributed automation capabilities for diverse environmental and process control applications.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSingle-channel AC dimmer with integrated fieldbus functionality.\u003c\/li\u003e\n  \u003cli\u003eAutomatic load type detection (handles ohmic, inductive, capacitive, and lamp loads).\u003c\/li\u003e\n  \u003cli\u003eFour-wire connection technology for secure, direct field wiring.\u003c\/li\u003e\n  \u003cli\u003eHigh-resolution control adjustable to 1% intervals.\u003c\/li\u003e\n  \u003cli\u003eRobust electrical isolation between K-bus logic and field voltage levels.\u003c\/li\u003e\n  \u003cli\u003eCompact 12 mm housing width maximizing DIN rail space efficiency.\u003c\/li\u003e\n  \u003cli\u003eFully compatible with standard KSxxxx series pluggable wiring systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial and industrial building automation systems.\u003c\/li\u003e\n  \u003cli\u003eIntegrated lighting and stage illumination controls.\u003c\/li\u003e\n  \u003cli\u003eVariable power regulation for process heating and small AC motor controls.\u003c\/li\u003e\n  \u003cli\u003eInfrastructure power management and distribution panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eKL2761\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnection Technology\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4-wire\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e230 V AC (50 Hz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMains Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e230 V AC (50 Hz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Output\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e600 VA (W)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMax. 2.7 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLoad Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOhmic, inductive, or capacitive (not mixed), lamp load, automatic load detection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Output Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.7 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShort-Circuit Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e20 to 40 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePhase control\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500 V (K-bus\/field voltage), 3750 V AC (1 min.)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLeakage Current (OFF State)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; 1 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption Power Contacts\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLoad only\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption K-Bus\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTyp. 95 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBit Width in Process Image\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOutput: 1 x 16-bit data (1 x 8-bit control\/status optional)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration\/Shock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Immunity\/Emission\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApprox. 60 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Snap directly onto standard 35 mm DIN rail (EN 60715) with secure physical latching.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Isolate all field power prior to wiring. Utilize the 4-wire terminal connections. For pluggable terminal blocks, use KSxxxx compatible modules.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Maintain clean convective airflow around the unit. Do not exceed the operating range of 0 to +55 degC.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the mounting rail is properly grounded to ensure correct EMI protection performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106570461547,"sku":"KL2761","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/kl2761-1tbljajl3h1.png?v=1776245144","url":"https:\/\/www.plcprotech.com\/fa\/products\/beckhoff-kl2761-bus-terminal-system-dimmer-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}