{"product_id":"bently-nevada-146824-0050-cylinder-pressure-transducer-cable","title":"Bently Nevada 146824-0050 Cylinder Pressure Transducer Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEngineered specifically for demanding reciprocating machinery diagnostic architectures, this heavy-duty signal conduit bridges the gap between cylinder-head pressure sensors and monitoring systems. The \u003cstrong\u003eBently Nevada 146824-0050\u003c\/strong\u003e provides a low-noise, highly shielded signal path essential for capturing high-frequency dynamic pressure changes and generating precise pressure-volume (PV) curves. Built to withstand the physical and environmental rigors of compressor decks, this \u003cstrong\u003e50-foot (15.2-meter) cable assembly\u003c\/strong\u003e ensures high-integrity data transmission in electromagnetically noisy and mechanically active environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 20px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Electromagnetic Shielding:\u003c\/strong\u003e Attenuates high-frequency noise from nearby heavy machinery, ignition systems, and power lines.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEngineered Industrial Connectors:\u003c\/strong\u003e Premium threaded terminals designed to maintain solid contact interfaces despite continuous structural vibration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDurable Sheathing:\u003c\/strong\u003e Outer jacket material chosen for resistance to oils, industrial solvents, and moisture commonly found on reciprocating compressor frames.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePre-Terminated Length:\u003c\/strong\u003e Factory-terminated and tested at a 50 ft (15.2 m) length option to maintain standard electrical impedance characteristics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 20px;\"\u003e\n  \u003cli\u003eReciprocating compressor cylinder pressure monitoring systems.\u003c\/li\u003e\n  \u003cli\u003eThermodynamic performance diagnostics and peak pressure monitoring.\u003c\/li\u003e\n  \u003cli\u003eContinuous machinery protection architectures utilizing the Bently Nevada 3500\/77M Cylinder Pressure Monitor.\u003c\/li\u003e\n  \u003cli\u003eDynamic combustion analysis on large industrial internal combustion engines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 12px; text-align: left; font-weight: bold; border: 1px solid #e2e8f0;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 12px; text-align: left; font-weight: bold; border: 1px solid #e2e8f0;\"\u003eValue \/ Specification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e146824-0050\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eCylinder Pressure Transducer Cable\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eCable Length\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e50 feet (15.2 meters)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eApplication Compatibility\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eDynamic Cylinder Pressure Transducers\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eUnited States\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e1.5 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe 146824 cable family features various dash suffixes designating overall length. To preserve signal integrity, never couple multiple shorter cables to reach a 50-foot span. Splicing can introduce severe impedance changes that degrade the microsecond-level transient response required by high-speed dynamic pressure monitors. If your installation requires a different length, always source the specific matching pre-cut suffix directly.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eHigh-impedance transducer signals are extremely susceptible to high-frequency electrostatic and magnetic interference. Running this cable adjacent to AC power lines or variable frequency drive (VFD) output lines without a dedicated, grounded conduit will corrupt pressure-volume plots, leading to false diagnostic indicators or inaccurate thermodynamic calculations in the monitoring terminal.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways ensure that the cable shield is grounded at only one end (typically at the local junction box or monitor rack) to prevent ground loops. Ensure that the transducer connector is fully dry and clean before mating. When securing the cable, maintain a minimum dynamic bend radius of 75 mm to prevent structural degradation of the internal shield foil and conductors over years of machinery operation.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e De-energize and lock out all machinery prior to installation near reciprocating compressor parts. Ensure all system pressure within the associated cylinders is fully vented and isolated before mounting sensors or routing routing cables near cylinder valves or high-vibration manifolds.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eInspect the cable connectors for physical damage, corrosion, or contamination before routing.\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eRoute the cable along structural framing, ensuring it is isolated from hot surfaces exceeding 120 degC and sharp metallic edges.\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eHand-tighten the threaded coupling at the transducer interface, then torque moderately to manufacturer specifications without over-stressing the housing.\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eSecure the cable with vibration-resistant ties to prevent whipping or dynamic wear during continuous compressor operation.\u003c\/span\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668313665899,"sku":"146824-0050","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/146824-0050-qfctyhm0yez_26969669-4021-4eef-bba7-5bc888bbb9c7.jpg?v=1765520938","url":"https:\/\/www.plcprotech.com\/fa\/products\/bently-nevada-146824-0050-cylinder-pressure-transducer-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}