{"product_id":"bently-nevada-330101-33-53-10-12-05-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-33-53-10-12-05 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330101-33-53-10-12-05\u003c\/strong\u003e: 3300 XL 8 mm proximity probe, 3\/8-24 UNF thread, Option 33 unthreaded length, Option 53 case length, Option 12 ClickLoc connector with FluidLoc cable, Option 05 CSA\/ATEX\/IECEx.\u003c\/p\u003e\n\u003cp\u003eUnlike standard configurations that use basic coaxial cables, this variant features a specialized FluidLoc cable (Option 12) constructed to prevent fluid migration along the interior of the cable sheath. This makes the probe suitable for applications where bearing oil or other machine fluids must be contained under differential pressure. The probe has an unarmored 3\/8-24 UNF threaded casing with a 3.3 in unthreaded section and a 5.3 in overall case length, leaving a 2.0 in threaded mounting portion. It interfaces with a 3300 XL Proximitor sensor and standard extension cables within a 1.0 m total length system configuration, serving as a non-contact eddy-current transducer to measure shaft vibration and axial displacement.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 12 FluidLoc cable prevents process fluids or bearing oil from migrating along the interior of the cable sheath.\u003c\/li\u003e\n  \u003cli\u003eOption 33 specifies a 3.3 in (84 mm) unthreaded length paired with a 5.3 in (135 mm) overall case length.\u003c\/li\u003e\n  \u003cli\u003e3\/8-24 UNF threaded casing manufactured from 303 stainless steel without external armor.\u003c\/li\u003e\n  \u003cli\u003eMiniature coaxial ClickLoc connector with no connector protector for click-verified connection.\u003c\/li\u003e\n  \u003cli\u003eOption 05 agency approval package certified for CSA, ATEX, and IECEx hazardous area installations.\u003c\/li\u003e\n  \u003cli\u003ePolyphenylene sulfide (PPS) probe tip with TipLoc molding for robust mechanical bonding.\u003c\/li\u003e\n  \u003cli\u003eStandard 1.0 m (3.3 feet) overall cable length, requiring a matching extension cable to complete the transducer loop.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOil and gas rotating machinery, including compressor and pump rotor displacement monitoring.\u003c\/li\u003e\n  \u003cli\u003eSteam and gas turbine bearing housing shaft vibration measurement.\u003c\/li\u003e\n  \u003cli\u003eHigh-pressure casing penetration installations requiring FluidLoc oil barrier performance.\u003c\/li\u003e\n  \u003cli\u003eCritical rotating machinery protection installations requiring ATEX\/IECEx hazardous location certs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Field\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eMeaning \/ Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model \/ Product Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330101\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA: Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e33\u003c\/td\u003e\n      \u003ctd\u003e3.3 in (84 mm) unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB: Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e53\u003c\/td\u003e\n      \u003ctd\u003e5.3 in (135 mm) overall case length (2.0 in threaded section)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC: Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD: Connector and Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, FluidLoc cable (oil-barrier design)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, and IECEx hazardous area approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330101-33-53-10-12-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasurement Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDisplacement (non-contact proximity)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Principle\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEddy current\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3\/8-24 UNF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCasing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 or 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm triaxial FluidLoc cable (FEP insulated)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated miniature coaxial ClickLoc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.3 in (84 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.3 in (135 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Probe Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 m (3.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils), nominal (begins at 0.25 mm \/ 10 mils gap)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eScale Factor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil), nominal when paired with 3300 XL Proximitor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 to +177 degC (-60 to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDifferential Pressure Sealing\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eViton O-ring probe case-to-tip pressure seal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength (Max Rated)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lbf) probe case to probe lead; 270 N (60 lbf) lead to extension cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Cable Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45 mm x 95 mm x 95 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.14 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe probe lead is terminated with a gold-plated miniature coaxial ClickLoc connector. This connector attaches directly to a 3300 XL extension cable by applying light hand force until a click is felt, establishing a coaxial RF signal path to the Proximitor sensor.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Gapping:\u003c\/strong\u003e Mount the probe with the physical gap (typically 1.27 mm or 50 mils for mid-range calibration) relative to the target surface. Verify gap voltage using a multimeter on the Proximitor output prior to locking the case threads.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Maintain a minimum cable bend radius of 25.4 mm (1.0 in). Route probe and extension cables away from high-voltage AC lines to prevent electrical interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFluid Sealing:\u003c\/strong\u003e This FluidLoc variant blocks fluid migration along the cable, but standard practice dictates sealing probe entry ports and junction boxes against external moisture ingress.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque Limits:\u003c\/strong\u003e Do not exceed the maximum rated installation torque of 11.2 Nm (100 in-lbf) for standard 3\/8-24 UNF forward-mounted probe cases. Over-tightening can damage the casing or threads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Certified for Canadian and US standards in hazardous locations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Intrinsic safety and non-incendive certifications for Zone 0, Zone 1, and Zone 2 gas\/dust atmospheres when installed per system drawings.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666572276075,"sku":"330101-33-53-10-12-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330101-33-53-10-12-05-3300-xl-8-mm-reverse-mount-probes-aatruwo14fb_126ca8b9-338f-4698-b6ed-36b816084146.jpg?v=1765440861","url":"https:\/\/www.plcprotech.com\/fa\/products\/bently-nevada-330101-33-53-10-12-05-3300-xl-8-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}