{"product_id":"bently-nevada-330101-39-63-10-02-cn-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-39-63-10-02-CN 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nEngineered for critical machinery displacement and vibration monitoring, the \u003cstrong\u003eBently Nevada 330101-39-63-10-02-CN\u003c\/strong\u003e provides robust eddy current sensing performance within the \u003cstrong\u003e3300 XL 8 mm Series\u003c\/strong\u003e transducer system. This sensor operates on high-frequency electromagnetic principles to track micro-level shaft movement, ensuring reliable diagnostic data input for plant safety and asset protection networks. Designed to withstand harsh industrial atmospheres, it features a \u003cstrong\u003e3\/8-24 UNF unarmored thread configuration\u003c\/strong\u003e, combining high mechanical durability with strict electrical precision to maintain calibrated performance over extensive operational life cycles.\n\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExceptional Fluid Resistance:\u003c\/strong\u003e The polyphenylene sulfide (PPS) probe tip is sealed to resist corrosive chemical exposure, high moisture levels, and industrial lubricants.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClickLoc Coaxial Connection:\u003c\/strong\u003e Equipped with a miniature ClickLoc coaxial connector to prevent accidental disconnects while maintaining constant signal conductivity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBroad Operating Temperature Range:\u003c\/strong\u003e Optimized to function reliably across severe thermal fluctuations common in turbine casings and compressor enclosures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterchangeability:\u003c\/strong\u003e Fully compatible with standard 3300 XL 8 mm Proximitor Sensors without requiring custom recalibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eSteam and gas turbine shaft vibration and axial position monitoring\u003c\/li\u003e\n  \u003cli\u003eCentrifugal and reciprocating compressor diagnostic protection\u003c\/li\u003e\n  \u003cli\u003eIndustrial gearbox shaft motion analysis and thrust bearing wear tracking\u003c\/li\u003e\n  \u003cli\u003eHeavy-duty generator and cooling tower fan vibration telemetry\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOption Code Configuration Table\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eOption Code\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eSelected Parameter Value\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eEngineering Definition\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003e330101\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3\/8-24 UNF thread, without armor\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eStandard non-armored probe housing with standard US threads\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003e39\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3.9 inches\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUnthreaded length of the metal probe barrel\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003e63\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e6.3 inches\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eTotal physical case length of the threaded probe body\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003e10\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eTotal integrated cable length\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003e02\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eMiniature coaxial ClickLoc, standard cable\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eStandard non-armored cable with click-lock connector interface\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCN\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eChina Specific Approvals\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRegion-specific safety and explosion protection certifications\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; width: 35%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSystem Compatibility\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNominal Scale Factor\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e7.87 V\/mm (200 mV\/mil) when paired with matching Proximitor\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eLinear Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2.0 mm (80 mils) starting at approximately 0.25 mm (10 mils) from the face\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eThread Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3\/8-24 UNF-2A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProbe Tip Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-51 to +177 degC (-60 to +350 degF)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eConnector Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eGold-plated brass ClickLoc miniature coaxial connector\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUnited States of America (USA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1.5 kg (3.3 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nTo ensure correct system calibration and noise rejection during turbine commissioning, implement the following industrial installation practices:\n\u003c\/p\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTarget Gap Setup:\u003c\/strong\u003e Set the physical mechanical gap so the dynamic voltage readout matches the linear midpoint (typically -10.0 VDC for standard 3300 XL systems) when measured across the Proximitor OUT and COM terminals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimize Crosstalk:\u003c\/strong\u003e Ensure a minimum lateral physical separation of at least 40 mm between probe tips if mounting multiple sensors in close proximity to prevent electromagnetic signal overlap.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Protection:\u003c\/strong\u003e Always clean the coaxial ClickLoc connectors with electronic contact cleaner before connection. Once joined, wrap the connection with self-coalescing silicone tape to exclude moisture and contaminants; do not use standard electrical adhesive tape.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0; font-size: 0.95rem;\"\u003e\n    Verify complete machinery de-energization and ensure the shaft has come to a total mechanical standstill before executing installation. Do not exceed the maximum installation torque rating of 11 N-m (100 in-lb) for the 3\/8-24 UNF casing to prevent mechanical shearing of the threaded barrel.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 0.75rem;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 1.75rem; height: 1.75rem; border-radius: 50%;\"\u003e1\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eCarefully thread the probe into the mounting bracket or casing by hand to avoid cross-threading. Secure the locknut to the recommended torque limit once final depth is reached.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 0.75rem;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 1.75rem; height: 1.75rem; border-radius: 50%;\"\u003e2\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eRoute the integrated 1.0-meter coaxial cable through protective industrial conduit, ensuring minimum bend radius rules (25.4 mm \/ 1.0 inch) are followed to avoid internal signal conductor damage.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 0.75rem;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; font-weight: bold; min-width: 1.75rem; height: 1.75rem; border-radius: 50%;\"\u003e3\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eJoin the coaxial ClickLoc connector to the extension cable terminal, ensuring the outer sleeve locks securely with an audible snap. Ensure the shield integrity is maintained up to the control panel termination block.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668301574507,"sku":"330101-39-63-10-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330101-39-63-10-02-CN-pxjcx1inuhl_c4094d30-7b14-4733-946f-0aa980a14040.jpg?v=1765520554","url":"https:\/\/www.plcprotech.com\/fa\/products\/bently-nevada-330101-39-63-10-02-cn-3300-xl-8-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}