{"product_id":"bently-nevada-330103-00-02-10-02-05-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330103-00-02-10-02-05 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eFully threaded M10 x 1 metric probe body (Option 00) with a 20 mm overall case length (Option 02) and a 1.0 m total length (Option 10) defines the specific mechanical configuration of the \u003cstrong\u003e330103-00-02-10-02-05\u003c\/strong\u003e \u003cstrong\u003e3300 XL 8 mm proximity probe\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eUnlike variants with standard 3\/8-24 UNF threads (such as the 330101 series), this probe features metric M10 x 1 threads and is designed without protective armor (unarmored standard FEP cable). The configuration is equipped with a miniature coaxial ClickLoc connector (Option 02) without a connector protector and is certified with CSA, ATEX, and IECEx hazardous area approvals (Option 05) for operation in Zone 0, 1, and 2 environments. The probe works as part of a complete 3300 XL system, providing a voltage output proportional to the gap distance between the probe tip and target surface to track shaft vibration and axial position.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eM10 x 1 metric thread configuration for direct installation in metric-threaded machine casings.\u003c\/li\u003e\n\u003cli\u003e0 mm unthreaded length (Option 00) provides a fully threaded casing for maximum mounting depth flexibility.\u003c\/li\u003e\n\u003cli\u003e20 mm overall case length (Option 02) designed for compact spaces and low-profile installation depths.\u003c\/li\u003e\n\u003cli\u003e1.0 m total length (Option 10) unarmored coaxial cable terminates in a miniature male ClickLoc connector.\u003c\/li\u003e\n\u003cli\u003eOption 05 approvals package certifies the probe for ATEX, IECEx, and CSA hazardous area classifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEddy-current fluid-film bearing vibration measurements on rotating machinery.\u003c\/li\u003e\n\u003cli\u003eShaft axial position and radial displacement tracking in steam turbines, gas turbines, and compressors.\u003c\/li\u003e\n\u003cli\u003eSpeed and Keyphasor reference measurements in industrial power plants and petrochemical facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription \/ Option Meaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e330103-00-02-10-02-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm proximity probe, M10 x 1 thread, without armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Unthreaded Length Option\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003e0 mm unthreaded length (fully threaded case)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Overall Case Length Option\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e20 mm overall case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC - Total Length Option\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 meter (3.3 feet) total system probe length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD - Connector and Cable-Type Option\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE - Agency Approval Option\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx hazardous area approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification Parameter\u003c\/th\u003e\n\u003cth\u003eValue \/ Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003e330103-00-02-10-02-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer System\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003eM10 x 1 metric thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Armor\u003c\/td\u003e\n\u003ctd\u003eWithout armor (unarmored standard FEP cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e0 mm (fully threaded case)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Case Length\u003c\/td\u003e\n\u003ctd\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Cable Length\u003c\/td\u003e\n\u003ctd\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc male connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Case Material\u003c\/td\u003e\n\u003ctd\u003eAISI 303 or 304 stainless steel (SST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Scale Factor\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe DC Resistance (R_PROBE)\u003c\/td\u003e\n\u003ctd\u003e7.59 ohm plus\/minus 0.50 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Impedance\u003c\/td\u003e\n\u003ctd\u003e75 ohm triaxial cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDifferential Pressure Seal\u003c\/td\u003e\n\u003ctd\u003eUp to 7.0 bar (100 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Cable Bend Radius\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensile Strength\u003c\/td\u003e\n\u003ctd\u003e330 N (75 lbf) probe case to lead; 270 N (60 lbf) at connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e17 mm x 17 mm x 1020 mm (H x W x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe probe lead terminates in a miniature male coaxial ClickLoc connector. Below is the electrical termination path:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnection Element\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCenter Conductor\u003c\/td\u003e\n\u003ctd\u003eSignal (RF\/DC Path)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Conductor (Shield)\u003c\/td\u003e\n\u003ctd\u003eCommon \/ Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSet initial probe gap using dc voltage (typically -10 Vdc corresponds to a nominal 1.27 mm or 50 mil gap for standard calibration).\u003c\/li\u003e\n\u003cli\u003eObserve minimum cable bend radius of 25.4 mm (1.0 inch).\u003c\/li\u003e\n\u003cli\u003eTighten the probe case to recommended torque limits: maximum case torque is 22.6 N-m (200 in-lb); recommended first-three-threads installation torque is 7.5 N-m (66 in-lb).\u003c\/li\u003e\n\u003cli\u003eUse safety wire holes in the lock nuts to secure the probe position.\u003c\/li\u003e\n\u003cli\u003eAvoid laying cables near high-voltage wiring to minimize electrical noise interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe Option 05 agency approval package certifies this probe for use in hazardous areas with the following standard registrations:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCSA: Class I, Zone 0, 1, 2; Groups A, B, C, D; Ex ia IIC\u003c\/li\u003e\n\u003cli\u003eATEX: II 1 G, Ex ia IIC T4\/T5 Ga\u003c\/li\u003e\n\u003cli\u003eIECEx: Ex ia IIC T4\/T5 Ga\u003c\/li\u003e\n\u003cli\u003eCE Mark: Complies with applicable European directives for electromagnetic compatibility and hazardous area safety\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666616742251,"sku":"330103-00-02-10-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330103-00-02-10-02-05-proximity-probes-03umvdprlt4_0eee6f1a-f3e2-4608-ba22-504c6e418ff7.jpg?v=1765444204","url":"https:\/\/www.plcprotech.com\/fa\/products\/bently-nevada-330103-00-02-10-02-05-3300-xl-8-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}