{"product_id":"bently-nevada-330104-00-05-20-02-05-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330104-00-05-20-02-05 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330104-00-05-20-02-05\u003c\/strong\u003e configuration is specified by a fully threaded case with M10 x 1 metric threads and an overall case length of 50 mm, equipped with integral FEP\/PFA-jacketed stainless steel armor. This eddy-current non-contact proximity probe features a 2.0-meter (6.6-foot) total cable length, terminated with a miniature coaxial ClickLoc connector, and holds CSA, ATEX, and IECEx approvals for hazardous areas.\u003c\/p\u003e\n\u003cp\u003eIn contrast to sibling variants that feature unthreaded portions (such as Option 01 or 02) or standard non-armored cables, the 330104 model is specifically armored along its cable length to withstand harsh industrial environments prone to mechanical abrasion. It operates as part of the 3300 XL 8 mm Proximity Transducer System, pairing with a matching 3300 XL extension cable and Proximitor sensor for continuous machinery shaft vibration, axial position, and speed monitoring.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully Threaded Metric Body:\u003c\/strong\u003e Option 00 specifies an unthreaded length of 0 mm (fully threaded case) with M10 x 1 threads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e50 mm Case Length:\u003c\/strong\u003e Option 05 establishes a case length of 50 mm for intermediate reach in standard metric brackets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegral Stainless Steel Armor:\u003c\/strong\u003e Armored cable protection (330104 base model) guards the coaxial line against crushing, cutting, and abrasive wear.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2.0 Meter Cable Length:\u003c\/strong\u003e Option 20 provides a total cable length of 2.0 meters (6.6 feet) directly attached to the probe head.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMiniature ClickLoc Coaxial Connector:\u003c\/strong\u003e Option 02 designates standard coaxial ClickLoc termination without an external connector protector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approval:\u003c\/strong\u003e Option 05 certifies compliance with CSA, ATEX, and IECEx safety standards for explosive environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMachinery rotor shaft vibration measurements on industrial steam turbines and gas turbines\u003c\/li\u003e\n\u003cli\u003eAxial thrust position displacement tracking on large centrifugal compressors and pumps\u003c\/li\u003e\n\u003cli\u003eRadial shaft dynamic motion monitoring inside fluid-film bearings\u003c\/li\u003e\n\u003cli\u003eSpeed sensing and keyphasor reference recording under high mechanical stress conditions\u003c\/li\u003e\n\u003cli\u003eCondition monitoring in oil and gas refineries, petrochemical plants, and power generation facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Code \/ Segment\u003c\/th\u003e\n\u003cth\u003eValue on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription \/ Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330104\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Probe, M10 x 1 thread, with protective stainless steel armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSegment A: Unthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003e0 mm unthreaded length (fully threaded case)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSegment B: Overall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e50 mm overall case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSegment C: Total Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e2.0 meters (6.6 feet) total cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSegment D: Connector \/ Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSegment E: Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx hazardous area approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330104-00-05-20-02-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThread Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM10 x 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnthreaded Length (Option A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase Length (Option B)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Cable Length (Option C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 meters (6.6 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type (Option D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFEP-jacketed stainless steel armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approval (Option E)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx approvals for hazardous areas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils), starting at approximately 0.25 mm (10 mils) from the target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5% nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDifferential pressure up to 7.0 bar (100 psi) across probe tip to case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.88 ohms +\/- 0.50 ohms (center to outer conductor for 2.0 m length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180 mm x 180 mm x 30 mm (H x W x D) (packaged\/coiled envelope)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.34 kg (340 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThread Engagement:\u003c\/strong\u003e Maximum length of thread engagement for M10 x 1 threads is 15 mm. Tighten probe hex to recommended torque using standard 10 mm wrench.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Maintain a minimum bend radius of 25.4 mm (1.0 inch) for armored coaxial cables to prevent internal signal attenuation or mechanical damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Torque:\u003c\/strong\u003e Connect standard coaxial ClickLoc connectors finger-tight. Avoid using metal pliers directly on the gold-plated surfaces unless otherwise specified.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnetic Cross-Talk:\u003c\/strong\u003e Ensure a minimum spacing of 40 mm between adjacent probe tips and avoid routing probe cables near high-voltage AC lines to prevent interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGapping:\u003c\/strong\u003e Set probe gap using a standard digital voltmeter or Proximitor output monitoring; standard radial vibration gap is -9.0 Vdc, corresponding to approximately 1.27 mm (50 mils) physical gap.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX \/ IECEx:\u003c\/strong\u003e Certified Ex ia IIC T5...T1 Ga for Zone 0 \/ Zone 1 installations when paired with intrinsically safe zener barriers or galvanic isolators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA\/NRTL:\u003c\/strong\u003e Class I, Zone 0, AEx\/Ex ia IIC T5...T1 Ga; Class I, Division 1, Groups A, B, C, D; Class II, Groups E, F, G; Class III.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Fully compliant with European Community Directive EMC 2014\/30\/EU and RoHS 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e SIL 2 certified with HFT = 0, and SIL 3 capable with HFT = 1 under IEC 61508.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666567098731,"sku":"330104-00-05-20-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330104-00-05-20-02-05-3300-xl-8-mm-proximity-probes-yvll0uspl3h_a6bea876-81e3-458c-bc28-066495de05ba.jpg?v=1765440761","url":"https:\/\/www.plcprotech.com\/fa\/products\/bently-nevada-330104-00-05-20-02-05-3300-xl-8-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}