{"product_id":"bently-nevada-330130-030-00-05-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-030-00-05 3300 XL Standard Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330130-030-00-05\u003c\/strong\u003e: \u003cstrong\u003e3300 XL standard extension cable\u003c\/strong\u003e specifies this particular transducer cable configuration, featuring a 3.0-meter length, unarmored standard coaxial construction, and certified hazardous area approvals. This cable forms a connection bridge between a 3300 XL 8 mm proximity probe and a 3300 XL Proximitor sensor, transferring high-frequency eddy-current signals with minimal degradation.\u003c\/p\u003e\n\u003cp\u003eThis unarmored standard configuration (Option 00) is used in conduit-protected routing or clean industrial environments where mechanical abrasion is not a concern, differentiating it from armored variants like option 01. The 3.0-meter length (Option 030) must be matched with a compatible probe length to achieve the required 5.0-meter or 9.0-meter total system length.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCable Length: 3.0 meters (9.8 feet) of triaxial cable.\u003c\/li\u003e\n  \u003cli\u003eCable Option: Standard FEP insulated triaxial cable without protective armor.\u003c\/li\u003e\n  \u003cli\u003eAgency Approval: Option 05 offers CSA, ATEX, and IECEx hazardous area certifications.\u003c\/li\u003e\n  \u003cli\u003eConnection Interface: Miniature male coaxial ClickLoc connector on one end, miniature female coaxial ClickLoc connector on the other.\u003c\/li\u003e\n  \u003cli\u003eCharacteristic Impedance: Nominal 75 ohm triaxial system impedance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eTypical industrial applications include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam and gas turbine vibration monitoring systems.\u003c\/li\u003e\n  \u003cli\u003eHydroelectric generator shaft displacement and thrust position measurement.\u003c\/li\u003e\n  \u003cli\u003eCentrifugal compressor and pump shaft vibration monitoring.\u003c\/li\u003e\n  \u003cli\u003eGearbox shaft bearing clearance and oil film monitoring.\u003c\/li\u003e\n  \u003cli\u003eMachinery protection in petrochemical and chemical processing plants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode Value\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330130\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Standard Extension Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA: Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e030\u003c\/td\u003e\n      \u003ctd\u003e3.0 meters (9.8 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB: Connector Protector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eStandard cable (unarmored, no connector protector)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, IECEx Approvals (for hazardous locations)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eValue \/ Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n      \u003ctd\u003e330130-030-00-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Length\u003c\/td\u003e\n      \u003ctd\u003e3.0 meters (9.8 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Type\u003c\/td\u003e\n      \u003ctd\u003eStandard coaxial cable, FEP insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCapacitance\u003c\/td\u003e\n      \u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCore Resistance (R_core)\u003c\/td\u003e\n      \u003ctd\u003e0.66 ohm +\/- 0.10 ohm (center conductor to center conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eJacket Resistance (R_jacket)\u003c\/td\u003e\n      \u003ctd\u003e0.20 ohm +\/- 0.04 ohm (outer conductor to outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Cable Diameter\u003c\/td\u003e\n      \u003ctd\u003e3.70 mm (0.15 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Material\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass or gold-plated beryllium copper\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating and Storage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Torque\u003c\/td\u003e\n      \u003ctd\u003eFinger tight\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003e0.14 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (Coiled Package)\u003c\/td\u003e\n      \u003ctd\u003e35 mm x 220 mm x 220 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnector End\u003c\/th\u003e\n      \u003cth\u003eType\u003c\/th\u003e\n      \u003cth\u003eConnection Interface Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Connection End\u003c\/td\u003e\n      \u003ctd\u003eMiniature Female Coaxial ClickLoc\u003c\/td\u003e\n      \u003ctd\u003eConnects to the miniature male ClickLoc coaxial connector on the 3300 XL 8 mm probe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProximitor Connection End\u003c\/td\u003e\n      \u003ctd\u003eMiniature Male Coaxial ClickLoc\u003c\/td\u003e\n      \u003ctd\u003eConnects to the miniature female ClickLoc coaxial connector on the 3300 XL Proximitor sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsure the sum of the extension cable length and the probe length matches the calibrated Proximitor sensor length (typically 5.0 meters or 9.0 meters total).\u003c\/li\u003e\n  \u003cli\u003eMaintain a minimum bend radius of 25.4 mm (1.0 inch) to prevent internal core damage.\u003c\/li\u003e\n  \u003cli\u003eHand-tighten connectors only (\"finger tight\"). Over-tightening with tools can damage the gold plating and ClickLoc mechanism.\u003c\/li\u003e\n  \u003cli\u003eUse conduit or protective packaging when routing in high-vibration or abrasive environments to prevent outer sheath wear.\u003c\/li\u003e\n  \u003cli\u003eIsolate field wiring from power lines and high-voltage electrical machinery to minimize electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCSA\/C-US: Class I, Zone 0, AEx\/Ex ia IIC T4\/T5 Ga; Class I, Div 1, Groups A, B, C, D; Class II, Groups E, F, G; Class III\u003c\/li\u003e\n  \u003cli\u003eATEX\/IECEx: II 1 G, Ex ia IIC T4\/T5 Ga; Ex nA IIC T4\/T5 Gc; Ex ec IIC T4\/T5 Gc\u003c\/li\u003e\n  \u003cli\u003eCE Mark: Compliant with EMC Directive 2014\/30\/EU and RoHS Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003eSIL Rating: SIL 2 compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666631225707,"sku":"330130-030-00-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-030-00-05-extension-cable-w54jhhazjdh_759a9b67-04a4-4661-a492-c0b996b4e3a8.jpg?v=1765444400","url":"https:\/\/www.plcprotech.com\/fa\/products\/bently-nevada-330130-030-00-05-3300-xl-standard-extension-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}