{"product_id":"bently-nevada-330130-040-02-00-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-040-02-00 3300 XL Standard Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 040 (4.0 m cable length) and Option 02 (standard cable with connector protector, without agency approvals) specify this 3300 XL series \u003cstrong\u003estandard extension cable\u003c\/strong\u003e configuration — \u003cstrong\u003e330130-040-02-00\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis specific cable configuration integrates a miniature coaxial ClickLoc connector shielded by a fluorosilicone connector protector. This design helps prevent moisture ingress, dust, and physical damage at the probe-to-extension cable connection point without requiring additional armor. The 4.0-meter length combines with a 1.0-meter probe to establish a 5.0-meter transducer system calibrated for 5-meter 3300 XL Proximitor sensors.\u003c\/p\u003e\n\u003cp\u003eUnlike armored options (such as B-options 01 or 03) that feature flexible stainless steel armor, the 330130-040-02-00 uses an unarmored 75 Ohm triaxial cable with FEP insulation, maintaining a tight 25.4 mm (1.0 in) minimum bend radius for routing flexibility in narrow conduits while relying on its fluorosilicone protector to shield the ClickLoc joint from environmental hazards.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 040 provides a 4.0-meter (13.1 feet) physical cable length for mid-range system reaches.\u003c\/li\u003e\n  \u003cli\u003eOption 02 includes a pre-installed fluorosilicone connector protector to guard the probe-to-cable junction against oil, dust, and moisture.\u003c\/li\u003e\n  \u003cli\u003eFEP (fluorinated ethylene propylene) insulation delivers stable dielectric performance across standard operating temperatures.\u003c\/li\u003e\n  \u003cli\u003eGold-plated ClickLoc connectors provide a secure, low-resistance coaxial coupling with tactile \"click\" feedback.\u003c\/li\u003e\n  \u003cli\u003eOption 00 specifies that agency approvals are not required, simplifying standard industrial configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRotating machinery monitoring systems (shaft vibration, axial position)\u003c\/li\u003e\n  \u003cli\u003eSteam turbines, gas turbines, and large industrial compressors\u003c\/li\u003e\n  \u003cli\u003ePetrochemical facilities, power generation plants, and water treatment operations\u003c\/li\u003e\n  \u003cli\u003eMachine enclosures requiring unarmored cable routing in protective conduits\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode Value\u003c\/th\u003e\n      \u003cth\u003eConfiguration Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330130\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Standard Extension Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA: Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e040\u003c\/td\u003e\n      \u003ctd\u003e4.0 meters (13.1 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB: Connector Protector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eStandard cable with connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNot required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330130-040-02-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 Ohm triaxial FEP insulated standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.0 meters (13.1 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector with fluorosilicone connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCore Resistance (R_CORE)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.88 ± 0.13 Ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOuter Conductor Resistance (R_JACKET)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.26 ± 0.05 Ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eExtension Cable Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Connector Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.565 N-m (5 in-lbf)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.136 kg (136 g)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4000 mm x 12.4 mm x 12.4 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnection Point\u003c\/th\u003e\n      \u003cth\u003eConnector Type\u003c\/th\u003e\n      \u003cth\u003eMating Component\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Connection End\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial female ClickLoc connector\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm proximity probe connector (male)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProximitor End\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial male ClickLoc connector\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Proximitor Sensor extension cable terminal\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo establish a stable machinery protection loop, observe the following engineering parameters during installation:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMaintain a physical cable bend radius of no less than 25.4 mm (1.0 in) to prevent internal conductor damage and phase shifts.\u003c\/li\u003e\n  \u003cli\u003eJoin the gold-plated coaxial ClickLoc connectors finger-tight. The maximum rated connector-to-connector tightening torque is 0.565 N-m (5 in-lbf).\u003c\/li\u003e\n  \u003cli\u003eEnsure the fluorosilicone connector protector is fully seated over the coaxial junction to seal out machine lubricants and environmental moisture.\u003c\/li\u003e\n  \u003cli\u003eRoute cables away from high-voltage electrical conduits to minimize electromagnetically induced noise in the transducer loop.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis product configuration (Option 00) is intended for use in environments where hazardous area approvals are not required. The component is manufactured under ISO 9001 strict quality management controls for machinery protection systems.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666862535019,"sku":"330130-040-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-040-02-00-3300-xl-standard-extension-cable-ecw1zmzthug_c092bae0-e4e3-4d34-b83c-041b9be74660.jpg?v=1765449344","url":"https:\/\/www.plcprotech.com\/fa\/products\/bently-nevada-330130-040-02-00-3300-xl-standard-extension-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}