{"product_id":"bently-nevada-330180-90-05-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-90-05 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 90 (9.0 meters system length, panel mount) and Option 05 (CSA, ATEX, IECEx approvals) specify this 3300 XL Proximitor Sensor configuration — \u003cstrong\u003e330180-90-05\u003c\/strong\u003e. This non-contacting sensor is a core conditioning module for Bently Nevada 3300 XL proximity transducer systems, which are used to measure radial shaft vibration, axial thrust position, and speed on rotating industrial machinery. The unit houses specialized oscillator and demodulator circuitry that generates a radio frequency signal, drives the connected eddy-current probe, and conditions the returning signal into a continuous analog voltage proportional to the dynamic gap distance.\u003c\/p\u003e\n\n\u003cp\u003eThis panel-mount variant features a standardized 4-hole mounting plate that shares an identical footprint with older Proximitor designs, simplifying legacy upgrades. The aluminum mounting base provides built-in electrical isolation, removing the requirement for separate isolator plates. Calibrated for 9.0-meter systems, the 330180-90-05 requires precise matching with a 3300 XL 8 mm proximity probe and extension cable that sum to a total physical length of exactly 9.0 meters. Option 05 compliance adds certified protection for hazardous locations, enabling safe deployment under global intrinsic safety and non-sparking\/non-incendive standards.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 90 configuration specifies a 9.0-meter system length calibration matched for 4-hole panel mounting.\u003c\/li\u003e\n  \u003cli\u003eOption 05 agency approval delivers certified safety for hazardous locations under CSA, ATEX, and IECEx approvals.\u003c\/li\u003e\n  \u003cli\u003eStandardized panel-mount footprint provides backwards compatibility with legacy Bently Nevada Proximitor sensors.\u003c\/li\u003e\n  \u003cli\u003eIntegrated electrical isolation on the mounting base eliminates the need for separate isolator hardware.\u003c\/li\u003e\n  \u003cli\u003eSpringLoc terminal block connectors provide secure field wiring connections without requiring special installation tools.\u003c\/li\u003e\n  \u003cli\u003eAdvanced RF\/EMI immunity satisfies European CE standards without requiring specialized shielded conduit or metallic enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial shaft vibration and dynamic positioning measurements on high-speed turbines, compressors, and pumps.\u003c\/li\u003e\n  \u003cli\u003eAxial thrust position and shaft eccentricity monitoring in power generation and petrochemical applications.\u003c\/li\u003e\n  \u003cli\u003eContinuous speed and tachometer input conditioning on industrial motors, generators, and fans.\u003c\/li\u003e\n  \u003cli\u003eMachinery protection monitoring loops connected to Bently Nevada 3500 Series racks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330180-90-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Proximitor Sensor, 9.0 m system length, panel mount, hazardous area approved\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOption A - Total Length and Mounting Option\u003c\/td\u003e\n      \u003ctd\u003e90\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet) system length, panel mount configuration\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOption B - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, IECEx Approvals (Intrinsically Safe \u0026amp; Non-Incendive)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330180-90-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Proximitor Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9.0 meters (29.5 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePanel mount (4-hole footprint)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (nominal -24 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Signal Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAnalog negative voltage (-1 Vdc to -17 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils), from 0.25 mm to 2.3 mm (10 to 90 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/-6.5%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Field Wiring Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e305 meters (1000 feet) of 3-conductor shielded triad cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e81.3 mm x 61.0 mm x 50.8 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e246 g (0.246 kg)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Label\u003c\/th\u003e\n      \u003cth\u003eFunction Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVT\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePower supply input (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCommon reference \/ system ground\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOUT\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAnalog voltage output signal (-1 Vdc to -17 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the Proximitor sensor on a clean, flat surface using the integrated panel-mount base; the mounting base provides integral electrical isolation directly.\u003c\/li\u003e\n  \u003cli\u003eUse tinned 3-conductor shielded triad field wiring cable with wire sizes ranging from 0.2 mm2 to 1.5 mm2 (16 AWG to 24 AWG).\u003c\/li\u003e\n  \u003cli\u003eInsert wires directly into the SpringLoc terminal strip; no special insertion or clamping tools are required.\u003c\/li\u003e\n  \u003cli\u003eLimit total field wiring between the Proximitor sensor and the monitoring system to a maximum of 305 meters (1000 feet) to prevent high-frequency signal roll-off.\u003c\/li\u003e\n  \u003cli\u003eEnsure that probe and extension cables maintain a minimum bend radius of 25.4 mm (1.0 inch) during routing.\u003c\/li\u003e\n  \u003cli\u003eFor hazardous locations, follow the certified wiring diagrams for intrinsically safe or non-incendive\/non-sparking requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEMC Standards:\u003c\/strong\u003e EN 61000-6-2 (Immunity for Industrial Environments), EN 61000-6-4 (Emissions for Industrial Environments)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Compliance:\u003c\/strong\u003e CE mark, RoHS Directive 2011\/65\/EU, China RoHS compliance (EFUP 15 years)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e SIL 2 certified (Hardware Fault Tolerance HFT = 0), SIL 3 capable in redundant (HFT = 1) systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals (Option 05):\u003c\/strong\u003e CSA, ATEX, and IECEx certifications for intrinsically safe (ia) and non-incendive\/non-sparking (nA, ec) installations in Class I, Division 1\/2 and Zone 0\/2 hazardous environments\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519060843,"sku":"330180-90-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330180-90-05-3300xl-5-8-mm-proximitor-sensor-fiezfwww3ne_ce9ec8c7-1922-48ed-8e3a-ab4d790e2b9b.jpg?v=1765440127","url":"https:\/\/www.plcprotech.com\/fa\/products\/bently-nevada-330180-90-05-3300-xl-proximitor-sensor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}