{"product_id":"bently-nevada-330881-28-04-85-03-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-04-85-03-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330881-28-04-85-03-02\u003c\/strong\u003e: PROXPAC XL metric proximity transducer assembly, featuring a 3300 XL 8 mm probe with multiple approvals (Option 28), a 40 mm standoff adapter (Option 04), an 85 mm probe penetration length (Option 85), one M20 cable fitting and two plugs (Option 03), and a 3\/4-14 NPT mounting thread (Option 02).\u003c\/p\u003e\n\n\u003cp\u003eThe PROXPAC XL combines a proximity probe and a 3300 XL Proximitor sensor into a single integrated assembly, eliminating the need for separate extension cables or remote Proximitor housings. The housing body is manufactured from glass-reinforced, conductive-fiber-filled polyphenylene sulfide (PPS) thermoplastic, which offers Type 4X and IP66 protection against harsh industrial environments. Field wiring connects directly to terminal blocks inside the housing, simplifying installation and maintenance on rotating machinery.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3300 XL 8 mm proximity probe with multiple hazardous area approvals (Option 28).\u003c\/li\u003e\n  \u003cli\u003e40 mm standoff adapter length (Option 04) for offset mechanical mounting.\u003c\/li\u003e\n  \u003cli\u003e85 mm probe penetration depth (Option 85) to reach internal target areas.\u003c\/li\u003e\n  \u003cli\u003eSupplied kit includes one M20 conduit fitting and two plugs (Option 03).\u003c\/li\u003e\n  \u003cli\u003e3\/4-14 NPT mounting thread (Option 02) designed for use with standoff adapters.\u003c\/li\u003e\n  \u003cli\u003eSelf-contained system eliminates the need for separate probe-to-Proximitor extension cabling.\u003c\/li\u003e\n  \u003cli\u003ePolyphenylene sulfide (PPS) thermoplastic housing rated for IP66 and Type 4X environments.\u003c\/li\u003e\n  \u003cli\u003eField wiring terminal block inside the housing allows direct connection to the monitor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAxial shaft position and radial shaft vibration monitoring on critical rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eNon-contacting displacement measurement on steam turbines, gas turbines, compressors, pumps, and fans.\u003c\/li\u003e\n  \u003cli\u003eHazardous area machinery protection requiring explosion-proof or intrinsically safe sensor installation.\u003c\/li\u003e\n  \u003cli\u003eSevere-environment machinery monitoring where moisture, chemical exposure, or electrostatic discharge is present.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer, Metric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA: Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e28\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB: Standoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e04\u003c\/td\u003e\n      \u003ctd\u003e40 mm Standoff Adapter length (B Dimension)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC: Probe Penetration Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e85\u003c\/td\u003e\n      \u003ctd\u003e85 mm Probe Penetration length (C Dimension)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD: Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eOne M20 fitting, two plugs (supplied as a kit)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE: Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT (required for Standoff Adapter Option)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eValue \/ Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel Number\u003c\/td\u003e\n      \u003ctd\u003e330881-28-04-85-03-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Series\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL (Metric)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProximitor Sensor Input\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe with a 1-metre cable length installed in the probe sleeve\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils), from approximately 0.25 mm to 2.3 mm (10 mils to 90 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n      \u003ctd\u003e-1 Vdc to -17 Vdc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/-5% over the linear range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Power Requirement\u003c\/td\u003e\n      \u003ctd\u003eRequires -17.5 Vdc to -26 Vdc (without barriers) at 12 mA maximum consumption\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n      \u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Resistance\u003c\/td\u003e\n      \u003ctd\u003e50 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFrequency Response\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB (with up to 305 metres of field wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Target Size\u003c\/td\u003e\n      \u003ctd\u003e15.2 mm (0.6 in) diameter (flat target)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Shaft Diameter\u003c\/td\u003e\n      \u003ctd\u003e76.2 mm (3.0 in) minimum recommended, 50.8 mm (2.0 in) absolute minimum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Case Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Cable Type\u003c\/td\u003e\n      \u003ctd\u003e1-metre, 75 ohm triaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Connector\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass ClickLoc connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic containing conductive fibers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Environmental Rating\u003c\/td\u003e\n      \u003ctd\u003eIP66 and Type 4X\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (operating)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing \u0026amp; Sensor Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (operating)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSleeve O-Ring Material\u003c\/td\u003e\n      \u003ctd\u003eNeoprene\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eGrounding Liner Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eGrounding: The grounding liner inside the housing provides a path to discharge static charges. Ensure the housing is properly grounded through the mounting structure or dedicated earth connection.\u003c\/li\u003e\n  \u003cli\u003eSealing: Use the neoprene O-ring provided between the sleeve and the housing. Apply appropriate thread sealant on the mounting threads to prevent moisture ingress.\u003c\/li\u003e\n  \u003cli\u003eConduit Connections: Route field wiring through the M20 fitting provided. Seal unused conduit entries with the supplied blanking plugs to maintain the IP66 environmental rating.\u003c\/li\u003e\n  \u003cli\u003eProximity Gap: Set the nominal gap between the probe tip and the shaft target at 1.27 mm (50 mils) to achieve centered operation in the 2.0 mm linear range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eElectrical Classification: Complies with the European CE mark\u003c\/li\u003e\n  \u003cli\u003eEnvironmental Protection: Housing IP66 rating (verified by BASEEFA report)\u003c\/li\u003e\n  \u003cli\u003eHazardous Area Approvals: Multiple Approvals (Option 28) covering North American (CSA), European (ATEX), and International (IECEx) standards for Zone 0, Zone 1, Zone 2, Class I Division 1, and Class I Division 2 hazardous environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666525647211,"sku":"330881-28-04-85-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-04-85-03-02-proximity-transducer-wgeeb2buii4_06b4432f-feb8-41e9-bc3c-350808d827ff.jpg?v=1765440269","url":"https:\/\/www.plcprotech.com\/fa\/products\/bently-nevada-330881-28-04-85-03-02-proxpac-xl-proximity-transducer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}