{"product_id":"bently-nevada-330881-28-10-148-03-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-10-148-03-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 28 (3300 XL 8 mm probe with Multiple Approvals), Option 10 (100 mm standoff adapter), and Option 148 (148 mm probe penetration) specify this \u003cstrong\u003ePROXPAC XL Proximity Transducer\u003c\/strong\u003e configuration — \u003cstrong\u003e330881-28-10-148-03-02\u003c\/strong\u003e. This integrated system combines a proximity probe and a Proximitor sensor into a single, self-contained metric assembly, completely eliminating the requirement for an external extension cable and separate Proximitor sensor housing. By routing the field wiring directly from the monitor to the terminal block inside the housing cover, installation footprint and connection complexity are substantially reduced.\u003c\/p\u003e\n\n\u003cp\u003eThis metric variant features an advanced molded polyphenylene sulfide (PPS) thermoplastic housing. The glass and conductive fiber reinforcement within the PPS material provides high mechanical strength and dissipates electrostatic charges. Rated for Type 4X and IP66 severe environments, the assembly includes one M20 conduit fitting with two plugs (Option 03) and a 3\/4-14 NPT mounting thread (Option 02) to maintain housing integrity and protect the internal sensor from moisture and environmental contaminants.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePre-installed 3300 XL 8 mm proximity probe and integrated Proximitor sensor in a single enclosure\u003c\/li\u003e\n  \u003cli\u003eOption 28 integration provides built-in multiple hazardous area certifications\u003c\/li\u003e\n  \u003cli\u003eOption 10 standoff adapter yields a fixed 100 mm metric spacing dimension\u003c\/li\u003e\n  \u003cli\u003eOption 148 penetration depth specifies a 148 mm metric probe sleeve\u003c\/li\u003e\n  \u003cli\u003eOption 03 conduit fitting kit provides one M20 fitting and two plugs\u003c\/li\u003e\n  \u003cli\u003eOption 02 mounting interface utilizes a 3\/4-14 NPT thread connection\u003c\/li\u003e\n  \u003cli\u003eConductive-fiber reinforced PPS thermoplastic housing rated for IP66 and Type 4X protection\u003c\/li\u003e\n  \u003cli\u003eElimination of extension cables reduces signal attenuation and connection failure points\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial vibration and axial position measurements on high-speed rotating shafts\u003c\/li\u003e\n  \u003cli\u003eMetric machinery casings requiring external probe depth adjustments\u003c\/li\u003e\n  \u003cli\u003eSevere-duty applications where separate probe, cable, and housing installations are impractical\u003c\/li\u003e\n  \u003cli\u003ePetrochemical plants, gas pipelines, refineries, and power generation steam turbines\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer, Metric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e28\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Standoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e100 mm Standoff Adapter length (ordered in increments of 10 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Probe Penetration Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e148\u003c\/td\u003e\n      \u003ctd\u003e148 mm Probe Penetration length (ordered in increments of 1 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eOne M20 fitting, two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT mounting thread (required when ordering Standoff Adapter Option)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-28-10-148-03-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer System (Metric)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRequires -17.5 Vdc to -26 Vdc at 12 mA maximum (without barriers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Input\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm proximity probe with 1-meter cable length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Linear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Scale Factor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB with up to 305 meters of field wiring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e15.2 mm (0.6 in) diameter (flat target)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHousing Material\u003c\/strong\u003e\n    \u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic containing conductive fibers\u003c\/td\u003e\n    \n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve and Retaining Chain\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOuter Sleeve \/ Retaining Screws\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeoprene\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration Isolation Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eExtra soft cellular silicone\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Housing \u0026amp; Sensor)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe Only)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible (when connections are protected)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Impact Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBASEEFA certified for two separate 4 Joule impacts at -39 degC and +115 degC; CSA verified for 7 Joule impact at room temperature\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eType 4X and IP66 rated\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/li\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHousing Grounding:\u003c\/strong\u003e Ensure the housing is properly grounded via the pre-installed internal grounding liner and plate to prevent electrostatic discharge build-up.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Sealing:\u003c\/strong\u003e Check that the neoprene sleeve O-ring is fully seated during installation. Seal any unused conduit ports with the supplied plugs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque Limits:\u003c\/strong\u003e Apply exactly 29.5 N-m (260 in-lb) to the retaining nut and 39.3 N-m (350 in-lb) to the probe sleeve locknut to secure the assembly without overstressing components.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMoisture Prevention:\u003c\/strong\u003e Install conduit drains or loops to prevent moisture and condensation from tracking through the conduit line into the housing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e EN 61000-6-2 (Industrial Immunity), EN 61000-6-4 (Industrial Emissions), EMC Directive 2014\/30\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e Option 28 specifies Multiple Approvals including Class I, Zone 0, AEx\/Ex ia IIC T4\/T5 Ga; Class I, Zone 2, AEx\/Ex nA IIC T4\/T5 Gc; Class I, Zone 2, AEx\/Ex ec IIC T4\/T5 Gc\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnclosure Protection:\u003c\/strong\u003e IP66 rating verified by BASEEFA and Type 4X rated\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666735198571,"sku":"330881-28-10-148-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-10-148-03-02-proxpac-xl-proximity-transducer-sij0b3nuvle_2f1bab0f-721a-4ce7-a37c-eaf38ab56e08.jpg?v=1765446771","url":"https:\/\/www.plcprotech.com\/fa\/products\/bently-nevada-330881-28-10-148-03-02-proxpac-xl-proximity-transducer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}