{"product_id":"bently-nevada-330881-br-04-034-06-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-BR-04-034-06-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption BR specifies INMETRO (Brazilian) approvals and a 3300 XL 8 mm probe configuration for this metric PROXPAC XL integrated transducer assembly — \u003cstrong\u003e330881-BR-04-034-06-02\u003c\/strong\u003e. This configuration integrates a metric PROXPAC XL housing, a 40 mm standoff adapter (Option 04), and a custom 34 mm probe penetration length (Option 034). The assembly features a heavy-duty sealing kit under Option 06, which provides one 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1-1\/2-14 NPT stainless steel reducer, and two plugs. The entire unit is designed to mount via a 3\/4-14 NPT thread (Option 02).\u003c\/p\u003e\n\n\u003cp\u003eBy housing both a 1-metre 3300 XL 8 mm proximity probe and a 3300 XL Proximitor sensor within a single self-contained housing, the \u003cstrong\u003e330881-BR-04-034-06-02\u003c\/strong\u003e eliminates the need for external extension cables and standalone Proximitor housings. This design directly reduces connection points, minimizes signal degradation, and simplifies wiring layouts by bringing field connections directly to the monitor. The housing is constructed from Polyphenylene Sulfide (PPS) molded thermoplastic reinforced with glass and conductive fibers, which provides Type 4X and IP66 environmental protection while safely dissipating electrostatic charges.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption BR: Features an integrated 3300 XL 8 mm proximity probe certified with INMETRO (Brazilian) hazardous area approvals.\u003c\/li\u003e\n  \u003cli\u003eOption 04: Features a metric standoff adapter with a specific length of 40 mm.\u003c\/li\u003e\n  \u003cli\u003eOption 034: Configured with a precise 34 mm probe penetration length.\u003c\/li\u003e\n  \u003cli\u003eOption 06: Includes one 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1-1\/2-14 NPT stainless steel reducer, and two plugs to secure the conduit interface.\u003c\/li\u003e\n  \u003cli\u003eOption 02: Standard 3\/4-14 NPT mounting thread configuration, required to support standoff adapter options.\u003c\/li\u003e\n  \u003cli\u003eConductive PPS Housing: Thermoplastic material design provides defense against corrosive chemical environments and dissipates static charges.\u003c\/li\u003e\n  \u003cli\u003eIntegrated Architecture: Built-in Proximitor sensor eliminates the traditional probe-to-sensor extension cable for a more direct signal path.\u003c\/li\u003e\n  \u003cli\u003eType 4X and IP66 Enclosure: Rated for direct hose-directed water exposure and harsh industrial locations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDynamic shaft vibration monitoring on critical rotating machinery\u003c\/li\u003e\n  \u003cli\u003eRotor axial position and thrust movement measurement\u003c\/li\u003e\n  \u003cli\u003eReciprocating compressor piston rod position and rod runout wear monitoring\u003c\/li\u003e\n  \u003cli\u003eShaft radial displacement and casing thermal expansion detection\u003c\/li\u003e\n  \u003cli\u003eApplications in petrochemical, refining, and power generation facilities requiring INMETRO hazardous area certifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eMeaning \/ Configuration\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-BR-04-034-06-02\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer Assembly (Metric)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBR\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with INMETRO (Brazilian) Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Standoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e04\u003c\/td\u003e\n      \u003ctd\u003e40 mm standoff adapter length (B Dimension)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Probe Penetration Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e034\u003c\/td\u003e\n      \u003ctd\u003e34 mm probe penetration length (C Dimension)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e06\u003c\/td\u003e\n      \u003ctd\u003eOne 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1-1\/2-14 NPT SST reducer, and two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT mounting thread (required with standoff adapter)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-BR-04-034-06-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Integrated Proximity Transducer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (without barriers) at 12 mA maximum consumption; -23 Vdc to -26 Vdc (with barriers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSupply Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 Ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 mm (80 mils); begins at approximately 0.25 mm (10 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVoltage Output Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-1 Vdc to -17 Vdc nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5% including interchangeability error\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eField Wiring Limit\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMaximum 305 m (1,000 ft) between sensor and monitor using recommended 1.0 mm2 (18 AWG) 3-conductor shielded triax cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene Sulfide (PPS) molded thermoplastic with glass and conductive fibers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnvironmental Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eType 4X and IP66\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Housing)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 degC to +100 degC (-60 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-51 degC to +177 degC (-60 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTarget Material Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 4140 Steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eAdhering to these guidelines helps prevent common installation issues and maintains system integrity:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eVerify that the 3\/4-14 NPT mounting threads are free of debris and properly matched before threading the standoff adapter into the machine casing.\u003c\/li\u003e\n  \u003cli\u003eEnsure the 8 mm probe tip maintains the recommended 1.27 mm (50 mils) gap to the target shaft for optimal linear range response.\u003c\/li\u003e\n  \u003cli\u003eRoute field wiring directly through the Option 06 fittings into the housing terminal block, securing the lid and lid screws to protect the internal Proximitor sensor from moisture and dust.\u003c\/li\u003e\n  \u003cli\u003eConfirm that the PPS housing's conductive fibers are grounded to allow effective dissipation of static electricity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eINMETRO Certifications: Intrinsically Safe (Ex ia IIC T4\/T5 Ga) and Non-sparking\/Increased safety (Ex nA\/Ex ec IIC T4\/T5 Gc) under Option BR.\u003c\/li\u003e\n  \u003cli\u003eEMC Directive: EN 61000-6-2 (Immunity) and EN 61000-6-4 (Emissions)\u003c\/li\u003e\n  \u003cli\u003eRoHS Directive: Compliant with European Union Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003eMaritime Standards: Certified under major classification rules where applicable\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666566312299,"sku":"330881-BR-04-034-06-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-br-04-034-06-02-proxpac-xl-housing-5cr2o3zuqsg_8f42fd74-247b-49be-aa0f-7106e471e2a6.jpg?v=1765440745","url":"https:\/\/www.plcprotech.com\/fa\/products\/bently-nevada-330881-br-04-034-06-02-proxpac-xl-proximity-transducer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}