{"product_id":"bently-nevada-330881-br-04-85-03-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-BR-04-85-03-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption BR specifies INMETRO (Brazil) Multiple Approvals with an integrated 3300 XL 8 mm probe, while Option 04 and Option 85 provide a 40 mm standoff adapter and 85 mm probe penetration for this metric assembly — the \u003cstrong\u003e330881-BR-04-85-03-02\u003c\/strong\u003e \u003cstrong\u003ePROXPAC XL Proximity Transducer\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis integrated design brings together the proximity probe, sleeve, and 3300 XL Proximitor sensor into a single, self-contained polymer housing. By eliminating the typical extension cable between probe and sensor, the assembly reduces field wiring complexity and simplifies installation on rotating machinery. The housing cover is molded from glass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers, providing Type 4X and IP66 protection against harsh chemical and moisture environments. Field wiring runs directly from the integrated terminal connections to monitoring systems, removing the need for a separate Proximitor sensor enclosure.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption BR provides INMETRO (Brazil) hazardous area approvals for zone-rated environments.\u003c\/li\u003e\n\u003cli\u003eOption 04 includes a 40 mm metric stainless steel standoff adapter to match specific casing clearances.\u003c\/li\u003e\n\u003cli\u003eOption 85 defines a probe penetration sleeve length of 85 mm.\u003c\/li\u003e\n\u003cli\u003eOption 03 supplies a metric installation fitting kit with one M20 conduit fitting and two plugs.\u003c\/li\u003e\n\u003cli\u003eOption 02 utilizes a standard 3\/4-14 NPT mounting thread for rigid mechanical attachment.\u003c\/li\u003e\n\u003cli\u003eSelf-contained design combines a 3300 XL 8 mm probe and a 1-meter Proximitor sensor in one housing.\u003c\/li\u003e\n\u003cli\u003eGlass-reinforced polyphenylene sulfide (PPS) housing resists chemical degradation and dissipates electrostatic charges.\u003c\/li\u003e\n\u003cli\u003eDirect terminal-to-monitor field wiring eliminates intermediate extension cables and separate driver enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShaft vibration and axial position monitoring on large industrial rotating assets.\u003c\/li\u003e\n\u003cli\u003eContinuous machinery protection in oil and gas, petrochemical, and power generation environments.\u003c\/li\u003e\n\u003cli\u003eEnvironments requiring strict compliance with Brazilian INMETRO hazardous area standards.\u003c\/li\u003e\n\u003cli\u003eWet, corrosive, or high-moisture installations where Type 4X and IP66 environmental protection is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eConfiguration Meaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330881-BR-04-85-03-02\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer Assembly (Metric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA - Probe and Approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBR\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe with INMETRO Multiple Approvals (Brazil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB - Standoff Adapter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003e40 mm Standoff Adapter Option (B Dimension)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC - Probe Penetration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85\u003c\/td\u003e\n\u003ctd\u003e85 mm Probe Penetration Option (C Dimension)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD - Fittings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eOne M20 fitting, two plugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE - Mounting Thread\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT mounting thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330881-BR-04-85-03-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated Proximity Transducer Assembly (Metric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Probe Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe (with 1-meter cable length installed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc without barriers at 12 mA maximum; -23 Vdc to -26 Vdc with barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-meter length, 75 Ohm triaxial, fluoroethylene propylene (FEP) insulated with gold-plated brass ClickLoc connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils) over 0.25 mm to 2.30 mm range (-1 Vdc to -17 Vdc nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal (plus\/minus 5% interchangeability error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than plus\/minus 0.025 mm (plus\/minus 1 mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB (with up to 305 meters \/ 1000 feet of field wiring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.2 mm (0.6 in) diameter (flat target)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Shaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50.8 mm (2.0 in) for cross-talk under 50 mV; 76.2 mm (3.0 in) recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType 4X, IP66 rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Threads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Penetration Sleeve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSleeve \u0026amp; Retaining Chain\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal Designation\u003c\/th\u003e\n\u003cth\u003eSignal Description\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e-VT\u003c\/td\u003e\n\u003ctd\u003ePower Supply Input (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eCommon Ground Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOUT\u003c\/td\u003e\n\u003ctd\u003eVibration\/Position Output Signal (nominal 7.87 V\/mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure correct mechanical alignment of the outer sleeve assembly during insertion. The standoff adapter must be properly threaded and torqued to avoid loose mechanical coupling. Maintain a recommended gap setting of 1.27 mm (50 mils) between the probe tip and target shaft surface. Use 3-conductor shielded twisted-pair field wiring of 0.2 to 1.5 mm2 (16 to 24 AWG) to connect directly to the integrated Proximitor terminal block inside the housing cover. Route the wiring through M20 fittings while sealing any unused conduit entrances using the supplied blanking plugs to maintain the IP66 and Type 4X rating.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe integrated transducer is certified with INMETRO hazardous area approvals for zone-rated environments in Brazil. The outer housing holds an IP66 rating verified by BASEEFA and complies with the European CE mark requirements.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666562838891,"sku":"330881-BR-04-85-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-br-04-85-03-02-housing-2lwukvzad1a_22e806b9-fd90-4c57-8279-2eb87e29d5ab.jpg?v=1765440687","url":"https:\/\/www.plcprotech.com\/fa\/products\/bently-nevada-330881-br-04-85-03-02-proxpac-xl-proximity-transducer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}