{"product_id":"bently-nevada-330901-00-12-70-01-05-3300-nsv-proximity-probe","title":"Bently Nevada 330901-00-12-70-01-05 3300 NSv Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eFully threaded 1\/4-28 UNF-2A steel probe case (Option 00) with a 1.2 in overall case length (Option 12) and a 7.0 m total standard cable length (Option 70) specifies the \u003cstrong\u003e330901-00-12-70-01-05\u003c\/strong\u003e configuration of this \u003cstrong\u003e3300 NSv proximity probe\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eThis unarmored probe configuration includes a miniature coaxial ClickLoc connector equipped with an integrated fluorosilicone connector protector (Option 01) and carries multiple hazardous area agency approvals (Option 05) for use in explosive atmospheres. It pairs with a 3300 XL NSv Proximitor Sensor and extension cable to measure non-contact eddy-current fluid-film bearing displacement on industrial rotating machinery where shaft diameters are smaller than 20 mm (0.8 in) or mounting clearances are tightly constrained. Unlike armored variants, this standard unarmored configuration offers optimal cable routing flexibility within clean conduit systems while maintaining robust insulation properties.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 00 specifies a fully threaded 1\/4-28 UNF-2A probe case with 0.0 in of unthreaded length.\u003c\/li\u003e\n  \u003cli\u003eOption 12 provides a 1.2 in overall case length for installations with minimal axial clearance.\u003c\/li\u003e\n  \u003cli\u003eOption 70 supplies a 7.0 m total system length, allowing direct connection to the Proximitor sensor.\u003c\/li\u003e\n  \u003cli\u003eOption 01 features a ClickLoc coaxial connector with a pre-installed fluorosilicone connector protector that seals out moisture and oil.\u003c\/li\u003e\n  \u003cli\u003eOption 05 offers multiple international certifications for hazardous environments, including ATEX, IECEx, and CSA approvals.\u003c\/li\u003e\n  \u003cli\u003eFluoroplastic (FEP) cable insulation provides resistance to chemicals and elevated temperatures.\u003c\/li\u003e\n  \u003cli\u003eHigh-strength polyphenylene sulfide (PPS) tip material resists erosion in harsh industrial atmospheres.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial vibration and axial position measurements on high-speed rotating shafts smaller than 20 mm (0.8 in).\u003c\/li\u003e\n  \u003cli\u003eAeroderivative gas turbines, centrifugal compressors, and small steam turbines.\u003c\/li\u003e\n  \u003cli\u003eSmall-bore industrial pumps, gearboxes, and electric motors with limited target area geometry.\u003c\/li\u003e\n  \u003cli\u003eTight clearance machinery monitoring requiring standard mount unarmored transducer configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330901-00-12-70-01-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Proximity Probe, 1\/4-28 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOption A - Unthreaded Length\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (fully threaded probe case)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOption B - Overall Case Length\u003c\/td\u003e\n      \u003ctd\u003e12\u003c\/td\u003e\n      \u003ctd\u003e1.2 in (30.5 mm) overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOption C - Total Length\u003c\/td\u003e\n      \u003ctd\u003e70\u003c\/td\u003e\n      \u003ctd\u003e7.0 meters (23.0 feet) total cable length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOption D - Connector and Cable Type\u003c\/td\u003e\n      \u003ctd\u003e01\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector with connector protector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOption E - Agency Approval\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (including ATEX, IECEx, and CSA)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330901-00-12-70-01-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Proximity Probe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Specification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1\/4-28 UNF-2A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Configuration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWithout armor (unarmored standard cable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.0 in\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.2 in (30.5 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.0 meters (23.0 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Configuration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector with fluorosilicone connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm coaxial, fluoroethylene propylene (FEP) insulated brown jacket\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.5 mm (60 mils), spanning from 0.25 mm to 1.75 mm (10 to 70 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +12.5% \/ -20%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.06 mm (+\/-2.3 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe DC Resistance (R_PROBE)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.9 +\/- 0.9 ohms (between center and outer conductor for 7.0 m length)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Pressure Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eViton O-ring differential pressure seal between tip and case\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Rated Tensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e220 N (50 lb) probe case to probe lead; 220 N (50 lb) lead to connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Cable Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHand-tighten the probe case into the threaded mounting port, then torque to a recommended torque of 5.1 N m (45 in lb) with a maximum limit of 7.3 N m (65 in lb).\u003c\/li\u003e\n  \u003cli\u003eEnsure the coaxial cable maintains a bend radius of at least 25.4 mm (1.0 in) along its routing path to avoid damage or transmission losses.\u003c\/li\u003e\n  \u003cli\u003eVerify that the total combined length of the probe and extension cable matches the system calibration length (e.g., a 7.0 m probe connects directly to a 7.0 m Proximitor sensor without an intermediate extension cable).\u003c\/li\u003e\n  \u003cli\u003eAvoid exposing the probe seal to temperatures below -34 degC (-30 degF) for sustained periods to maintain pressure seal integrity.\u003c\/li\u003e\n  \u003cli\u003eEnsure the fluorosilicone connector protector is seated correctly on the connection point to keep out moisture, oil, and dust.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e European Community Directive 2014\/30\/EU; Standards EN 61000-6-2 (Immunity) and EN 61000-6-4 (Emissions).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e European Community Directive 2011\/65\/EU; China RoHS compliant (EFUP 15 years per SJ\/T 11364-2024).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e SIL 2 (HFT = 0) and SIL 3 (HFT = 1) certified.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Areas (Option 05):\u003c\/strong\u003e CSA\/cNRTLus, ATEX, and IECEx approvals. Intrinsically Safe Ex ia IIC T5...T1 Ga and Ex ia IIIC T90degC...T280degC Dc; Non-Sparking\/Increased Safety Ex nA\/Ex ec IIC T5...T1 Gc for Zone 2 \/ Division 2 environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666625032555,"sku":"330901-00-12-70-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330901-00-12-70-01-05-3300-nsv-proximity-probes-dshwt3anyzl_07ef3b22-c485-40a2-91c5-89bf43ea1067.jpg?v=1765444320","url":"https:\/\/www.plcprotech.com\/fa\/products\/bently-nevada-330901-00-12-70-01-05-3300-nsv-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}