{"product_id":"bently-nevada-330908-10-55-05-02-00-3300-nsv-proximity-probe","title":"Bently Nevada 330908-10-55-05-02-00 3300 NSv Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330908-10-55-05-02-00\u003c\/strong\u003e specifies this \u003cstrong\u003e3300 NSv proximity probe\u003c\/strong\u003e configuration, which features a 3\/8-24 UNF thread, a 1.0-inch unthreaded length (Option 10), and a 5.5-inch overall case length (Option 55) without protective armor. This non-contact transducer component is paired with a 0.5-meter (20-inch) coaxial cable (Option 05) terminated with a miniature coaxial ClickLoc connector (Option 02) without a connector protector, requiring no specific agency approvals (Option 00).\u003c\/p\u003e\n\n\u003cp\u003eUnlike the armored 330909 variant designed for mechanical defense, this unarmored 330908 configuration is streamlined for tight installations such as process gas compressors or aeroderivative gas turbines. The ClickLoc connector provides a secure mechanical coupling to the extension cable, preventing loosening in environments subject to vibration, while the 3\/8-24 UNF thread pattern simplifies direct threaded installation.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 10 designates a 1.0-inch (25.4 mm) unthreaded length, allowing specific stand-off adjustment in threaded mounting brackets.\u003c\/li\u003e\n  \u003cli\u003eOption 55 defines a 5.5-inch (139.7 mm) overall case length for deep-reach installation configurations.\u003c\/li\u003e\n  \u003cli\u003eOption 05 provides a 0.5-meter (20-inch) total probe length, optimized for short-run connections to an extension cable.\u003c\/li\u003e\n  \u003cli\u003eOption 02 specifies a miniature coaxial ClickLoc connector on a standard coaxial cable without an integrated connector protector.\u003c\/li\u003e\n  \u003cli\u003eOption 00 designates that agency approvals are not required, simplifying supply chains in non-hazardous industrial environments.\u003c\/li\u003e\n  \u003cli\u003eThread configuration utilizes a standard 3\/8-24 UNF-2A thread pattern for mounting compatibility.\u003c\/li\u003e\n  \u003cli\u003eUnarmored probe body design reduces physical envelope and eases routing through standard conduits.\u003c\/li\u003e\n  \u003cli\u003ePolyphenylene sulfide (PPS) probe tip material and AISI 304 stainless steel case construction resist chemical degradation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCentrifugal air and refrigeration compressors.\u003c\/li\u003e\n  \u003cli\u003eProcess gas compressors with restricted access or small targets.\u003c\/li\u003e\n  \u003cli\u003eRadial vibration and position measurements on shafts smaller than 51 mm (2 inches).\u003c\/li\u003e\n  \u003cli\u003eAxial (thrust) position measurements on flat targets smaller than 15 mm (0.6 inches).\u003c\/li\u003e\n  \u003cli\u003eTachometer, speed, and phase reference (Keyphasor) applications with tight clearance limitations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330908-10-55-05-02-00\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Proximity Probe, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 in (25.4 mm) unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e55\u003c\/td\u003e\n      \u003ctd\u003e5.5 in (139.7 mm) overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003e0.5 meter (20 in) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNot required \/ Non-hazardous areas\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330908-10-55-05-02-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Thread\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3\/8-24 UNF-2A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWithout armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.5 mm (60 mils), starting at approximately 0.25 mm (10 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.06 mm (+\/-2.3 mils) over linear range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5 or 7 meters (probe plus extension cable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Cable\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm coaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e220 N (50 lb) maximum probe case to probe lead; probe lead to extension cable connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF) operating and storage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMoisture Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.0 +\/- 0.5 ohms (between center conductor and outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax Recommended Case Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e11.3 N m (100 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003ePort \/ Interface\u003c\/th\u003e\n      \u003cth\u003eConnection Type\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable End Connector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature Coaxial ClickLoc Male\u003c\/td\u003e\n      \u003ctd\u003eConnects directly to the 3300 NSv extension cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Gap:\u003c\/strong\u003e Mount the probe to establish a nominal gap of 1.0 mm (40 mils) from the target surface for calibrated mid-range operation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCase Torque:\u003c\/strong\u003e Tighten the probe case to a maximum recommended torque of 11.3 N m (100 in-lb). For the first three threads of the engagement, do not exceed 7.5 N m (66 in-lb) to prevent damage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBend Radius:\u003c\/strong\u003e Ensure any bends in the 75 ohm FEP coaxial cable maintain a minimum bend radius of 25.4 mm (1.0 inch) to preserve electrical integrity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Care:\u003c\/strong\u003e Hand-tighten the miniature coaxial ClickLoc connectors until they click into place. Use silicone tape or connector protectors to shield connections from moisture and fluids.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis specific configuration (Option 00) is designated for non-hazardous locations and does not carry regional explosion-proof certifications. The product series complies with European Community directives including EMC Directive 2014\/30\/EU (standards EN 61000-6-2 and EN 61000-6-4) and RoHS Directive 2011\/65\/EU.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666577355115,"sku":"330908-10-55-05-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330908-10-55-05-02-00-3300-nsv-proximity-probes-sofzqu4141p_7bd1a1f2-67f9-4d3c-810e-12a6efd3676b.jpg?v=1765440921","url":"https:\/\/www.plcprotech.com\/fa\/products\/bently-nevada-330908-10-55-05-02-00-3300-nsv-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}