{"product_id":"bently-nevada-330930-65-05-00-3300-nsv-extension-cable","title":"Bently Nevada 330930-65-05-00 3300 NSv Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330930-65-05-00\u003c\/strong\u003e is a 3300 NSv extension cable configured for industrial displacement monitoring where physical clearances are limited and small shaft target geometries are present. This cable has an active length of 6.5 meters (21.3 feet) and is constructed with protective stainless steel armor without an outer FEP jacket, featuring a pre-installed connector protector at the probe-to-cable joint. It acts as the signal transmission link within a 7.0-meter 3300 XL NSv proximity transducer system, connecting a 0.5-meter 3300 NSv proximity probe to a 3300 XL NSv Proximitor Sensor.\u003c\/p\u003e\n\u003cp\u003eThe rugged armored construction on this variant provides mechanical guarding against abrasion, pinching, and impact forces in tight machinery casing environments, while omitting the outer polymer FEP jacket to reduce the cable outer diameter and comply with specific chemical or weight constraints. The integrated connector protector prevents liquids, lubricating oils, and moisture from contaminating the gold-plated coaxial ClickLoc joint, maintaining clean signal transmission over long operating cycles. This specific configuration is supplied under Option 00 (approvals not required) and is designed for general-purpose, non-hazardous industrial areas.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e6.5-meter length option establishes a complete 7.0-meter transducer measurement chain when mated with a 0.5-meter proximity probe.\u003c\/li\u003e\n  \u003cli\u003eFlexible stainless steel armor provides heavy physical protection against mechanical wear without the added bulk of an FEP jacket.\u003c\/li\u003e\n  \u003cli\u003eIntegrated connector protector shields the delicate coaxial junction against process lubricants, moisture, and debris.\u003c\/li\u003e\n  \u003cli\u003eGold-plated brass ClickLoc coaxial connectors secure connections with a positive locking mechanism to prevent loosening from machine vibration.\u003c\/li\u003e\n  \u003cli\u003eProprietary CableLoc design provides robust pull strength to prevent accidental separation of the probe-to-cable connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis extension cable is used in critical rotating machinery applications requiring compact eddy-current displacement measurements:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCentrifugal and axial industrial compressors with limited internal mounting space.\u003c\/li\u003e\n  \u003cli\u003eAeroderivative gas turbines and high-speed turbomachinery with small target areas.\u003c\/li\u003e\n  \u003cli\u003eSmall-bore pump shafts and tight-clearance radial vibration measurement paths.\u003c\/li\u003e\n  \u003cli\u003eGeneral-purpose industrial machinery installations where hazardous area approvals are not required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe 330930-65-05-00 part number represents the following configuration options defined by Bently Nevada:\u003c\/p\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Identifier\u003c\/th\u003e\n      \u003cth\u003eCode Value\u003c\/th\u003e\n      \u003cth\u003eConfiguration Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330930\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Extension Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA: Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e65\u003c\/td\u003e\n      \u003ctd\u003e6.5 meters (21.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB: Connector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eWith stainless steel armor, without FEP jacket, with connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eAgency approval not required (general purpose)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330930-65-05-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Family Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL NSv Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm coaxial\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStainless steel armor (without FEP jacket)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass ClickLoc coaxial connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e6.5 meters (21.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Protector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIncluded (installed on female end)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable DC Resistance (Center Conductor)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.220 ohms\/meter (0.067 ohms\/foot)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable DC Resistance (Shield)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.066 ohms\/meter (0.020 ohms\/foot)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e69.9 pF\/meter (21.3 pF\/foot) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 inch)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eExtension Cable Mass (Armored)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e64 g\/meter (0.7 oz\/foot) typical (approximately 416 g total cable mass)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUp to 100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector-to-Connector Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFinger tight recommended; maximum torque 0.56 Nm (5 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eProper field installation ensures low signal-to-noise ratios and consistent transducer measurements:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAlways verify that the sum of the probe length and extension cable length matches the calibration length of the Proximitor Sensor (7.0 meters in this configuration).\u003c\/li\u003e\n  \u003cli\u003eObserve the minimum bend radius of 25.4 mm (1.0 inch) when routing the armored cable through conduit or machinery casings to prevent coaxial core damage.\u003c\/li\u003e\n  \u003cli\u003eEnsure the connector protector is fully seated over the probe-to-cable ClickLoc junction to prevent chemical or lubricant ingress.\u003c\/li\u003e\n  \u003cli\u003eUse silicone self-fusing tape (such as Bently Nevada part 03200006) for extra protection if the connector protector is exposed to extreme environments (note that tape is not recommended inside machinery casings exposed directly to hot turbine oil).\u003c\/li\u003e\n  \u003cli\u003eSecure the armored cable at regular intervals using appropriate clips or mounting blocks to prevent whip or mechanical wear during high-vibration operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666548027755,"sku":"330930-65-05-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330930-65-05-003300-nsv-extension-cable-ibbe1bxeunr_0677e8a7-993d-4b4d-a96e-b41383476a68.jpg?v=1765440545","url":"https:\/\/www.plcprotech.com\/fa\/products\/bently-nevada-330930-65-05-00-3300-nsv-extension-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}