{"product_id":"bently-nevada-3500-15-04-04-00-3500-series-power-supply-module","title":"Bently Nevada 3500\/15-04-04-00 3500 Series Power Supply Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEngineered to deliver clean, highly stable electrical power to the 3500 machinery protection system rack, the \u003cstrong\u003eBently Nevada 3500\/15-04-04-00\u003c\/strong\u003e functions as a high-reliability, low-voltage power supply module. This module accepts low-voltage DC inputs to convert incoming primary power into the regulated voltages required by the monitoring and communications modules housed within the rack. It supports a dual-redundant power configuration to maximize system availability in heavy industrial process plants, petroleum refineries, and power generation facilities where continuous asset monitoring is crucial.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRedundant Power Support:\u003c\/strong\u003e Accommodates primary and secondary low-voltage DC feeds to ensure uninterrupted system operations during a single power source failure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Diagnostics:\u003c\/strong\u003e Front-panel status LEDs indicate 'Power Supply OK' and 'Over-Temperature' conditions for immediate field troubleshooting.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTransient Isolation:\u003c\/strong\u003e Built-in internal filters isolate sensitive rack components from electromagnetic interference (EMI) and external line transients.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Safety Architecture:\u003c\/strong\u003e Features automatic overcurrent and overvoltage shutdown mechanisms to safeguard installed monitoring modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eTurbine, generator, and compressor vibration monitoring networks.\u003c\/li\u003e\n  \u003cli\u003eOil and gas petrochemical plant machinery protection racks.\u003c\/li\u003e\n  \u003cli\u003eCritical balance-of-plant rotating machinery assets.\u003c\/li\u003e\n  \u003cli\u003ePower generation steam and gas turbine systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications Table\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eModel Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3500 Machinery Protection System\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3500\/15-04-04-00\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePrimary Supply Option\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eLow Voltage DC (20 to 30 Vdc)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eBackup Supply Option\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eLow Voltage DC (20 to 30 Vdc)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eInput Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e20 to 30 Vdc\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eAgency Approvals\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNone (00 Option)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eU.S.A.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1.39 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2.50 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe 3500\/15-04-04-00 model represents an all-low-voltage DC configuration. When replacing older 3500\/15 units, ensure that your rack's backplane power terminal input block is designed specifically for 24 Vdc nominal feeds. Installing a DC module into a rack pre-wired for high-voltage AC (such as 3500\/15-01-xx options) will damage the internal terminal pins. If migrating from legacy configurations, check physical card guide clearances on early-revision 3500 chassis.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eUnder full rack loads (all 14 monitor slots populated with dual-channel relays or high-draw seismic cards), thermal dissipation within the power supply modules increases. Maintain a clear ventilation path above and below the 3500 enclosure. Avoid combining a low-voltage DC supply and a high-voltage AC supply within the same chassis unless the rack backplane has been explicitly verified for mixed-voltage dual-source layouts, as failure to switch over during a fault can occur with unmatched impedance feeds.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways utilize shielded, twisted pair cables (minimum 12 AWG) for the DC input terminals to protect the backplane from common-mode noise. Ensure the frame ground terminal on the input block is tied back to your instrument clean ground with a low-impedance connection. This prevents ground loops from corrupting the transient monitoring data signals passing through the neighboring monitor cards.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e De-energize all primary and secondary external DC power feeds before attempting to slide the power supply module into the rack slot. Failing to completely isolate incoming power lines can cause hazardous electric arcing, leading to physical degradation of the backplane contacts and unexpected rack reboots.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 0.75rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eIsolate and verify that the low-voltage DC supply lines measure below 2 Vdc before connecting any conductors to the rear terminal blocks.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 0.75rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eSlide the module along the chassis card guides in the designated slot (usually the extreme left of the 3500 rack) until the connectors bottom out firmly.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 0.75rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eSecure the module's integrated faceplate screws to the frame chassis to ensure robust grounding and vibration-proof mounting.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 0.75rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eEnergize the DC source supply and verify the front faceplate green 'OK' LED is stably illuminated.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668312420715,"sku":"3500\/15-04-04-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3500-15-04-04-00-qgfqcvyhad1_bd2b8efa-9cbe-4e55-af66-6eb3d51e9690.jpg?v=1765520894","url":"https:\/\/www.plcprotech.com\/fa\/products\/bently-nevada-3500-15-04-04-00-3500-series-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}