{"product_id":"bently-nevada-3500-22-01-02-00-3500-22m-transient-data-interface","title":"Bently Nevada 3500\/22-01-02-00 3500\/22M Transient Data Interface","description":"\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/22-01-02-00\u003c\/strong\u003e acts as the primary communication and data collection gateway for the 3500 machinery protection system. This \u003cstrong\u003e3500 Series Transient Data Interface Module\u003c\/strong\u003e (TDI) forms a vital bridge between the operational hardware rack and host analysis software platforms, including System 1 Condition Monitoring and Diagnostic software alongside standard 3500 System Configuration configurations. By consolidating the core interface capabilities of a traditional 3500\/20 Rack Interface Module (RIM) with the high-bandwidth telemetry processing of an external communication processor, the unit delivers integrated data infrastructure. It interfaces with M series monitoring modules to continuously gather steady-state and high-density transient dynamic waveform recordings, routing them cleanly via a dedicated Ethernet connection. The module provides standard static data capture out of the box, with options to unlock expanded high-resolution wave capture utilizing a specialized enabling disk. Installed directly into the dedicated control slot next to the power supplies, it manages rack-wide operations without interfering with the independent, safety-critical protection loops of individual machinery monitors.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Communications Framework:\u003c\/strong\u003e Merges standard rack interface module duties with communication processor architectures into a single slot footprint.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimultaneous Waveform Telemetry:\u003c\/strong\u003e Captures both synchronous and asynchronous dynamic waveform recordings across up to 48 distinct monitoring channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Data Management:\u003c\/strong\u003e Buffers comprehensive pre-alarm and post-alarm histories, logging static data points at 100 millisecond intervals during critical machine events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiber Optic Network Support:\u003c\/strong\u003e Uses a full-duplex multimode 100Base-FX fiber interface to maintain optical isolation and extend field data distances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Interfering Operation:\u003c\/strong\u003e Functions outside the hardware trip protection loop to prevent network management faults from compromising machinery shutdown safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Mode Security:\u003c\/strong\u003e Employs a physical front-panel keylock switch to secure configuration states and eliminate remote tampering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eReal-Time Transient Shaft Orbit and Waveform Capture during Machine Startup and Coastdown \u003c\/li\u003e\n\u003cli\u003eMachinery Condition Monitoring and Predictive Diagnostics with System 1 Software Networks \u003c\/li\u003e\n\u003cli\u003eMulti-Channel Vibration Data Acquisition on Steam Turbines and High-Speed Compressors \u003c\/li\u003e\n\u003cli\u003eHigh-Speed Counter and Keyphasor Event Timing Coordination Across the Control Rack \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe component options below outline the explicit breakdown for the specific configuration \u003cstrong\u003e3500\/22-01-02-00\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/22\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransient Data Interface Module and I\/O \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Transient Data Interface Type (use for standard monitoring applications) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100Base-FX (Fiber Optic) Ethernet I\/O Module Type \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (No Agency Approvals) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eElectrical\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.5 Watts \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard OK Relay Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5A @ 24 Vdc \/ 120 Vac, 120 Watts \/ 600 VA Switched Power maximum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Contact Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eArc suppressors provided ; operates as Normally Energized \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Port Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-B port supporting BN Host Protocol up to 115.2 kbaud maximum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUSB Cable Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 meters (16.4 ft) maximum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRear Port Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100Base-FX Fiber Optic, full duplex multimode conforming to IEEE802.3u \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Cable Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 metres (6560 feet) maximum via MT-RJ Male connector \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKeyphasor Inputs Supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour 3500 system Keyphasor signals up to 20 kHz tracking \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAsynchronous Frequency Spans\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Hz, 20 Hz, 50 Hz, 100 Hz, 200 Hz, 500 Hz, 1000 Hz, 2000 Hz, 5000 Hz, 10 kHz, 20 kHz, 30 kHz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eMechanical\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (A Baker Hughes Company) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Module Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.91 kg (2.0 lbs) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.20 kg (0.44 lbs) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Slot Allocation (Front)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height front slot (Slot 1 adjacent to power supplies) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Slot Allocation (Rear)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Connector Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMT-RJ Male interface on unit (requires MT-RJ Female cable connector) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eEnvironmental\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +149 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePowered Internal Battery Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38 years @ 50 degC (122 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnpowered Internal Battery Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 years @ 50 degC (122 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe interface connections on the front main module and the 100Base-FX fiber optic back-chassis I\/O interface utilize the following port maps:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePort\/Component Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunctional Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Panel USB Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-B Configuration Port for local programming or machinery data retrieval \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Panel Keylock Switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHardware switch setting the module to RUN mode or PROGRAM mode \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRear I\/O Terminal 7\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOK Relay interface indicating the health status of the overall rack \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRear I\/O Terminal 8\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSignal Common external grounding terminal for single point connection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRear I\/O Port 11\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMT-RJ Male fiber optic port for 100Base-FX network connection and configuration \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRear I\/O Terminal 10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem Contact inputs (Trip Multiply, Alarm Inhibit, and Rack Reset inputs) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Slot Placement:\u003c\/strong\u003e The TDI main processor module must always be slid into Slot 1 of the 3500 system rack, situated directly adjacent to the primary power supply modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpgrade Precedence Advisory:\u003c\/strong\u003e When upgrading an old rack from a 3500\/20 RIM module, you must extract the old RIM processor and its companion RIM I\/O card before sliding the new TDI components into place. Leaving legacy RIM I\/O cards inside the backplane during TDI startup will cause physical circuit damage to the new TDI processor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Grounding Configuration:\u003c\/strong\u003e To tie the Signal Common loop to an instrument ground via the 2-pin connector on the rear I\/O card, you must slide the selector toggle located on the side of the Power Input Module (PIM) toward the \"HP\" arrow. This effectively isolates signal common loops from safety chassis grounds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB Isolation Caution:\u003c\/strong\u003e The designated USB download cable (part number 123M4610) must be deployed for configuration connection to maintain structural electrical isolation between the main rack chassis and your programming PC. Ensure the connected laptop is operating entirely on battery power (not plugged into grid mains) to block ground loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Complies with part 15 of the FCC Rules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directive:\u003c\/strong\u003e European Community Directive 2014\/30\/EU; Standards: EN 61000-6-2 (Industrial Immunity) and EN 61000-6-4 (Industrial Emissions).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e European Community Low Voltage Directive 2014\/35\/EU conforming to standard EN 61010-1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Directive:\u003c\/strong\u003e Complies with European Community Directive 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime Standards:\u003c\/strong\u003e DNV GL rules for classification (Ships, offshore units) and ABS Rules for Condition of Classification Part 1 (Steel Vessels \/ Offshore Structures).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668295905643,"sku":"3500\/22-01-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350022-01-02-00-apdcm2n5bx2_23c31574-c987-4fd2-b170-1473e29678c3.jpg?v=1765520386","url":"https:\/\/www.plcprotech.com\/fa\/products\/bently-nevada-3500-22-01-02-00-3500-22m-transient-data-interface","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}