{"product_id":"bently-nevada-3500-60-01-cn-3500-series-temperature-monitor-module","title":"Bently Nevada 3500\/60-01-CN 3500 Series Temperature Monitor Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProcessing inputs directly from RTDs and Thermocouples, the \u003cstrong\u003eBently Nevada 3500\/60-01-CN\u003c\/strong\u003e provides dedicated, continuous machinery protection within the 3500 Series chassis by monitoring critical machine temperatures without relying on legacy analog recorder outputs. This module is engineered for high-density, high-reliability applications where temperature monitoring is integrated directly into the digital control architecture of the facility.\u003c\/p\u003e\n\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThis specific configuration uses the \u003cstrong\u003eRTD\/TC Non-isolated I\/O Module\u003c\/strong\u003e with internal terminations, optimizing panel space and streamlining terminal wiring. Equipped with \u003cstrong\u003eCN approvals\u003c\/strong\u003e, it is compliant with country-specific regulatory standards for installation in demanding industrial environments.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eContinuous Monitoring:\u003c\/strong\u003e Accepts both Resistance Temperature Detector (RTD) and Thermocouple (TC) inputs to compare against user-defined alarm setpoints.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInternal Terminations:\u003c\/strong\u003e Compact termination design minimizes external wiring components and reduces the footprint required in marshalling cabinets.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNo Recorder Outputs:\u003c\/strong\u003e Streamlined design focused on digital integration via the 3500 backplane, eliminating redundant analog loop hardware.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Alarm Logic:\u003c\/strong\u003e Provides independent Alert and Danger setpoints for each of its active channels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eSteam, gas, and hydro turbine bearing temperature tracking.\u003c\/li\u003e\n  \u003cli\u003eLarge electric motor and generator stator winding protection.\u003c\/li\u003e\n  \u003cli\u003eHigh-pressure reciprocating and centrifugal compressor thermal diagnostics.\u003c\/li\u003e\n  \u003cli\u003ePumping station and mechanical gearbox bearing casing safety loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3500\/60-01-CN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3500 Machinery Protection System\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMonitor Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eTemperature Monitor (No Recorder Outputs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eI\/O Module Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eRTD\/TC Non-isolated I\/O Module, Internal Terminations\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eNominal 7 Watts\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eAgency Approvals\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eCN (Country Specific Approvals \/ China Standards Compliant)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eUnited States (USA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e2.0 kg \/ 4.4 lbs\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eConnections \u0026amp; Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eTerminal Block Section\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eRTD\/TC Input Terminals\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eAccepts 3-wire or 4-wire RTDs, or direct thermocouple element connections.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShield Terminals\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eInternal chassis-ground connection points for drain wire shielding.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2d3748; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe -01 non-isolated internal termination I\/O module is physically distinct from the -02 isolated equivalent. If replacing an isolated unit with this module, ensure that ground loop possibilities have been analyzed and eliminated in your field wiring layout. Use the 3500 Rack Configuration Software to confirm channel assignments and sensor parameters match the previous module's database profile.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2d3748; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBecause this is a non-isolated I\/O module, the thermocouple and RTD sensors must be electrically isolated at the point of measurement to prevent ground potential differences from corrupting system data or damaging the input circuitry. Avoid routing sensor field wiring in close proximity to high-power phase cables to minimize electromagnetic interference (EMI).\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2d3748; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen utilizing thermocouples with internal termination blocks, Cold Junction Compensation (CJC) is automatically managed at the local terminals. To prevent temperature read errors, do not subject the rear of the 3500 rack or the termination blocks to direct drafts or rapid localized temperature variations.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e De-energize the entire 3500 rack before inserting or removing the I\/O module. Do not hot-swap non-isolated I\/O cards while field wiring is connected and energized. Ensure field sensor lines are fully discharged of static charge prior to terminating connections.\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.25rem;\"\u003eVerify that the 3500 system power is switched off and lock-out procedures are active.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.25rem;\"\u003eInsert the main monitor module into the front slot of the 3500 rack and tighten the securing chassis screws.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.25rem;\"\u003eAlign and install the 3500\/60-01-CN I\/O module into the corresponding rear slot of the rack.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.25rem;\"\u003eTerminate your field RTD\/TC wiring according to the channel layout specified in your plant design drawings, ensuring correct polarity and shield isolation.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668277948779,"sku":"3500\/60-01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350060-01-cn-vskb13ivnyf_97905a98-dcce-481a-8ca9-4a8365505dd9.jpg?v=1765520314","url":"https:\/\/www.plcprotech.com\/fa\/products\/bently-nevada-3500-60-01-cn-3500-series-temperature-monitor-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}