{"product_id":"bently-nevada-84661-33-standard-armored-interconnect-cable","title":"Bently Nevada 84661-33 Standard Armored Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 84661-33\u003c\/strong\u003e is a heavy-duty standard armored interconnect cable assembly engineered to establish high-integrity data loops between machinery transducers and centralized monitoring platforms. This specialized signal link features a stainless steel armor wrap over a shielded 0.382 mm2 (22 AWG) multi-conductor cable core, safeguarding sensitive measurements from heavy mechanical impacts, structural abrasion, and severe cutting stresses. To guarantee uncompromised channel fidelity within damp or unconditioned field positions, the assembly is outfitted with a moisture-resistant female connector at the High Temperature Velocity Sensor (HTVS) end and industrial ring lugs at the monitor system end. Built to withstand extensive operational fluctuations, the internal shielding configuration minimizes high-frequency noise and ground path loop disruptions across wide temperature spans.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWrapped in a ruggedized stainless steel armor casing for robust mechanical field protection.\u003c\/li\u003e\n\u003cli\u003eConstructed using internal 0.382 mm2 (22 AWG) shielded instrumentation cabling.\u003c\/li\u003e\n\u003cli\u003eFactory-terminated with a specialized moisture-resistant female plug on the HTVS sensor end.\u003c\/li\u003e\n\u003cli\u003ePre-configured with heavy-duty industrial ring lugs on the central monitoring system terminal side.\u003c\/li\u003e\n\u003cli\u003eOptimized electrical shielding layout prevents electromagnetic noise coupling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-integrity dynamic signal routing from field-installed HTVS velocity sensors to core asset protection monitors.\u003c\/li\u003e\n\u003cli\u003eHarsh unconditioned process areas demanding stainless steel armor shielding against extreme wear or abrasion.\u003c\/li\u003e\n\u003cli\u003eHydroelectric generation plants and critical rotating machinery exposed to wet, high-humidity environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe model designation matrix for this standard armored interconnect cable follows a structured length selection pattern. The base assembly prefix is paired with a specific suffix indicating the total cable length in feet.\u003c\/p\u003e\n\u003cp\u003eUse the configuration table below to identify or specify alternative orderable model numbers based on plant length layout demands, featuring both Imperial (Feet) and Metric (Meters) conversion formats:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrderable Model\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCable Length (Feet)\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCable Length (Meters)\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e84661-12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 ft\u003c\/td\u003e\n\u003ctd\u003e3.6 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e84661-33\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33 ft\u003c\/td\u003e\n\u003ctd\u003e10.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e84661-40\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 ft\u003c\/td\u003e\n\u003ctd\u003e12.1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e84661-66\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e66 ft\u003c\/td\u003e\n\u003ctd\u003e20.1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e84661-33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Armored Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.382 mm2 (22 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Design Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShielded with outer armor overbraid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Interface Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoisture-resistant female connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor Interface Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRing lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-29 to 121 degC (-20 to 250 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States (U.S.A.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Position\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConnection Interface Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHTVS Sensor End\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoisture-resistant female connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor End\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRing lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLay out the armored cable run along designated panel channels or open structural areas, ensuring the path remains clear of tight pinching zones that could collapse the protective armor layer.\u003c\/li\u003e\n\u003cli\u003eAlign and thread the moisture-resistant female connector firmly onto the HTVS velocity sensor head interface until the protective seal is completely seated.\u003c\/li\u003e\n\u003cli\u003eAnchor the industrial ring lugs securely to the assigned terminal block points inside the monitoring system cabinet, optimizing terminal screw torque to suppress vibrational loosening.\u003c\/li\u003e\n\u003cli\u003eSeparate the instrumentation cable trajectory from adjacent primary motor power distribution conduits to reduce the risk of field noise induction.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668308193643,"sku":"84661-33","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/84661-33-b2tkpzvmmkt_e9754d5d-2df4-4874-959a-00ff97256d69.jpg?v=1765520745","url":"https:\/\/www.plcprotech.com\/fa\/products\/bently-nevada-84661-33-standard-armored-interconnect-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}