{"product_id":"bently-nevada-9200-03-05-01-00-9200-two-wire-velocity-seismoprobe-transducer","title":"Bently Nevada 9200-03-05-01-00 9200 Two-wire Velocity Seismoprobe Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eMonitoring absolute casing vibration is critical for detecting mechanical faults in large rotating machinery, and the \u003cstrong\u003eBently Nevada 9200-03-05-01-00\u003c\/strong\u003e provides the precise measurement required for these industrial environments. This self-generating, moving-coil \u003cstrong\u003etwo-wire velocity seismoprobe transducer\u003c\/strong\u003e converts mechanical vibration into a proportional voltage output without requiring any external excitation power. This specific configuration operates on a vertical axis, making it highly effective for continuous diagnostics on critical plant assets.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e9200-03-05-01-00\u003c\/strong\u003e is built with an integrated circular base featuring a 1\/4-in 20 UNC stud for robust physical coupling to machine casings. The top-mounted terminal block connector allows for secure wiring directly within local terminal boxes. Because it operates down to a low minimum frequency of 4.5 Hz, it is capable of tracking slow-speed structural vibrations and unbalance conditions across various turbine and pump applications.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSelf-generating velocity sensor design operates without an external power source.\u003c\/li\u003e\n  \u003cli\u003eDesigned for vertical mounting orientations (90 degrees +\/-2.5 degrees tolerance).\u003c\/li\u003e\n  \u003cli\u003eLow-frequency response threshold starting at 4.5 Hz (270 cpm).\u003c\/li\u003e\n  \u003cli\u003eConvenient top-mounted terminal block for simplified and secure wiring.\u003c\/li\u003e\n  \u003cli\u003eRugged circular mounting base with a integrated 1\/4-in 20 UNC stud.\u003c\/li\u003e\n  \u003cli\u003eSealed, durable mechanical construction ideal for demanding industrial areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam turbine and gas turbine casing vibration monitoring\u003c\/li\u003e\n  \u003cli\u003eIndustrial pump and compressor casing diagnostic systems\u003c\/li\u003e\n  \u003cli\u003eHeavy-duty electric motors and generators\u003c\/li\u003e\n  \u003cli\u003eDraft fans, cooling tower fans, and blowers\u003c\/li\u003e\n  \u003cli\u003eGeneral machinery protection systems in power generation and chemical plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eManufacturer\u003c\/strong\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\n      \u003ctd\u003e9200-03-05-01-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eProduct Series\u003c\/strong\u003e\n      \u003ctd\u003e9200 Seismoprobe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eTransducer Type\u003c\/strong\u003e\n      \u003ctd\u003eTwo-wire Velocity Transducer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eMounting Angle Option\u003c\/strong\u003e\n      \u003ctd\u003e90 degrees +\/-2.5 degrees (Vertical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eMinimum Operating Frequency\u003c\/strong\u003e\n      \u003ctd\u003e4.5 Hz (270 cpm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eConnector Option\u003c\/strong\u003e\n      \u003ctd\u003eTop-mount terminal block\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eMounting Base\u003c\/strong\u003e\n      \u003ctd\u003eCircular; 1\/4-in 20 UNC stud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eAgency Approval Option\u003c\/strong\u003e\n      \u003ctd\u003eNo approvals required\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eHeight\u003c\/strong\u003e\n      \u003ctd\u003e10.2 cm (4.0 inches) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eDiameter\u003c\/strong\u003e\n      \u003ctd\u003e4.1 cm (1.6 inches) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eWeight\u003c\/strong\u003e\n      \u003ctd\u003e0.3 kg (0.66 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\n      \u003ctd\u003eUSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eProper installation is vital for ensuring accurate vibration signal transmission. The mounting surface on the machine casing must be clean, flat, and perpendicular to the axis of measurement. Thread the 1\/4-in 20 UNC mounting stud directly into the tapped hole and torque to standard engineering limits to prevent signal attenuation or sensor detachment. Align the sensor within the vertical mounting tolerance (90 degrees +\/-2.5 degrees). Use shielded, twisted-pair cabling to connect the terminal block to the monitoring system, ensuring the shield is grounded at the instrument end only to prevent ground loops.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668296724843,"sku":"9200-03-05-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/9200-03-05-01-00-2wvpki002wy_1e01400b-7f71-4866-976e-aebff3524321.jpg?v=1765520418","url":"https:\/\/www.plcprotech.com\/fa\/products\/bently-nevada-9200-03-05-01-00-9200-two-wire-velocity-seismoprobe-transducer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}