{"product_id":"bently-nevada-990-10-70-01-00-vibration-transmitter","title":"Bently Nevada 990-10-70-01-00 Vibration Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 990-10-70-01-00\u003c\/strong\u003e is a two-wire, loop-powered vibration transmitter intended primarily for original equipment manufacturers (OEMs) of centrifugal air compressors, small pumps, motors, or fans. This industrial-grade unit conditions dynamic inputs from a 3300 NSv proximity probe and its matching extension cable, translating raw displacement into a proportional 4 to 20 mA industry-standard loop output. The hardware features a 0 to 10 mils peak-to-peak ($0-250 \\mu\\text{m}$ pp) full-scale vibration range configured for a 7.0-meter system length layout. Equipped with a built-in Proximitor sensor, non-interacting zero and span adjustments, and a specialized Not OK\/Signal Defeat safety circuit, it delivers continuous vibration trending directly to machinery control systems and PLCs.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEquipped with an integrated Proximitor sensor requiring no external conditioning unit.\u003c\/li\u003e\n\u003cli\u003eFeatures a non-isolated PROX OUT coaxial connector providing direct dynamic vibration and gap voltage output for machinery diagnostics.\u003c\/li\u003e\n\u003cli\u003eBuilt-in non-interacting zero and span potentiometers for accurate field loop calibration.\u003c\/li\u003e\n\u003cli\u003eIntegrated Test Input pin enables swift loop verification utilizing an external function generator.\u003c\/li\u003e\n\u003cli\u003eDesigned with a Not OK\/Signal Defeat circuit to prevent false machinery alarms from loose connections or faulty hardware.\u003c\/li\u003e\n\u003cli\u003eFeatures a potted construction method providing resistance within high humidity (up to 100% condensing) operating environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous peak-to-peak vibration trending on centrifugal air compressors.\u003c\/li\u003e\n\u003cli\u003eLocalized overall vibration tracking loops for small industrial pumps, motors, or fans.\u003c\/li\u003e\n\u003cli\u003eDirect integration of dynamic non-contacting probe metrics into PLC-based control infrastructure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information Break Down\u003c\/h3\u003e\n\u003cp\u003eThe model code \u003cstrong\u003e990-10-70-01-00\u003c\/strong\u003e represents a pre-configured combination of four specific ordering options:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Part\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelected Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull-Scale Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e0 to 10 mils peak-to-peak (0 to 250 micrometers peak-to-peak)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003ctd\u003e7.0 meters (23.0 feet) system length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail clips integrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo approvals\/certifications required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990-10-70-01-00 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVibration Transmitter \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull-Scale Option (10)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-10 mils pp ($0-250 \\mu\\text{m}$ pp) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Length Option (70)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.0 meters (23.0 feet) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Option (01)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail clips \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approval Option (00)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot required \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Input Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+12 to +35 Vdc input at the transmitter terminal \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Output Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mAdc over specified full-scale range (2-wire) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ±1.5% over specified full-scale range \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Loop Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 ohms including cable at 35 Vdc \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Limiting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 mA typical \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProx Out Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kOhm output impedance calibrated for a 10 MOhm load \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProx Out Linear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 mm (55 mils) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 mV\/$\\mu\\text{m}$ (200 mV\/mil) ±6.5% typical \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 Hz to 6,000 Hz +0, -3 dB \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature (Transmitter)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +85 degC (-31 degF to +185 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature (Transmitter)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submerged \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.43 kg (0.9 lbm) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSecurely mount the transmitter chassis onto standard industrial infrastructure via the pre-installed 35 mm DIN rail clips.\u003c\/li\u003e\n\u003cli\u003eTerminate the external supply leads to terminal blocks E1 and E2, ensuring input loop potential remains within the required +12 to +35 Vdc operational boundaries.\u003c\/li\u003e\n\u003cli\u003eRoute the matching 7.0-meter extension cable from the 3300 NSv probe directly into the integrated coaxial port, avoiding excessive thread engagement limits to mitigate terminal binding risks.\u003c\/li\u003e\n\u003cli\u003eIsolate all interconnecting communication loop paths from adjacent high-voltage primary motor power lines to minimize potential electromagnetic noise coupling.\u003c\/li\u003e\n\u003cli\u003eFor safety diagnostics using grounded, AC-powered test equipment, interface via a 122115-01 Test Adapter to maintain isolation and protect loop signaling path integrity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666540294507,"sku":"990-10-70-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-10-70-01-00-vibration-transmitter-q1beombryzw_1670b565-7dd9-4a9d-8140-17eb4ae853a9.jpg?v=1765440460","url":"https:\/\/www.plcprotech.com\/fa\/products\/bently-nevada-990-10-70-01-00-vibration-transmitter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}