{"product_id":"delta-electronics-vfd13amh43ansaa-mh300-series-variable-frequency-drive","title":"Delta Electronics VFD13AMH43ANSAA MH300 Series Variable Frequency Drive","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for precise speed and torque control of three-phase AC induction and synchronous motors, the Delta Electronics \u003cstrong\u003eVFD13AMH43ANSAA\u003c\/strong\u003e is a high-performance variable frequency drive belonging to the MH300 Series. Designed to handle both heavy-duty and normal-duty operating profiles, this compact frequency converter offers dynamic motor regulation with flexible carrier frequency adjustments. It operates directly from a 380V to 480V AC grid, providing robust electrical safety and reliable operation across diverse industrial automation architectures.\u003c\/p\u003e\n\n\u003cp\u003eThe unit features a fanless, natural cooling design which eliminates a common mechanical point of failure, making it highly suitable for environments where fan maintenance is restricted. With integrated support for multiple motor control modes and safe torque off functionality, this drive ensures seamless integration into modern factory control networks and machinery setups.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDual-rating capabilities optimizing performance for heavy-duty (HD) and normal-duty (ND) industrial machinery applications.\u003c\/li\u003e\n  \u003cli\u003eNatural cooling design utilizing a high-efficiency heatsink configuration to eliminate mechanical fan maintenance requirements.\u003c\/li\u003e\n  \u003cli\u003eWide input voltage tolerance of -15% to +10% to ensure operational stability during grid fluctuations.\u003c\/li\u003e\n  \u003cli\u003eAdjustable carrier frequency ranging from 2 kHz to 15 kHz to manage acoustic motor noise and thermal constraints.\u003c\/li\u003e\n  \u003cli\u003eIP20-rated protective housing suitable for panel mounting within clean, dry industrial enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMachine tool spindles and metalworking systems.\u003c\/li\u003e\n  \u003cli\u003eTextile machinery and high-speed spinning frames.\u003c\/li\u003e\n  \u003cli\u003eWoodworking cutting and routing equipment.\u003c\/li\u003e\n  \u003cli\u003ePackaging, labeling, and processing conveyors.\u003c\/li\u003e\n  \u003cli\u003eCentrifugal fans, pumps, and localized ventilation installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDelta Electronics\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eVFD13AMH43ANSAA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMH300 Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eD\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3-phase AC 380V to 480V (-15% to +10%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e323 to 528 Vac\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Frequency Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApplicable Motor Output (Heavy Duty)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.5 kW (7.5 HP)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Output Capacity (Heavy Duty)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9.9 kVA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Output Current (Heavy Duty)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e13.0 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Input Current (Heavy Duty)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e14.3 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApplicable Motor Output (Normal Duty)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.5 kW (10 HP)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Output Capacity (Normal Duty)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e11.1 kVA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Output Current (Normal Duty)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e14.5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Input Current (Normal Duty)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e16.0 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCarrier Frequency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 to 15 kHz (Factory setting: 4 kHz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCooling Method\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNatural cooling\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIngress Protection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.0 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the unit vertically on a flat, non-flammable surface inside a control cabinet to allow proper vertical convective airflow.\u003c\/li\u003e\n  \u003cli\u003eEnsure clearance zones around the heatsink conform to OEM technical standards for natural cooling dissipation.\u003c\/li\u003e\n  \u003cli\u003eGround the drive using a low-impedance connection directly to the main system ground terminal.\u003c\/li\u003e\n  \u003cli\u003eUtilize shielded motor cables and route control wiring separately from power and motor lines to minimize electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Delta Electronics","offers":[{"title":"Default Title","offer_id":53102142783851,"sku":"VFD13AMH43ANSAA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/vfd13amh43ansaa-bzzbg3tozal.png?v=1776138068","url":"https:\/\/www.plcprotech.com\/fa\/products\/delta-electronics-vfd13amh43ansaa-mh300-series-variable-frequency-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}