{"product_id":"honeywell-51304419-150-mc-iolx02-standard-i-o-link-extender-card","title":"Honeywell 51304419-150 MC-IOLX02 Standard I\/O Link Extender Card","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProviding critical signal extension and isolation within Honeywell Distributed Control Systems (DCS), the \u003cstrong\u003eHoneywell 51304419-150\u003c\/strong\u003e is a conformally coated \u003cstrong\u003eMC-IOLX02 Standard I\/O Link Extender Card\u003c\/strong\u003e designed to extend the physical range of redundant I\/O Link communication paths. This module ensures stable, deterministic data transmission between local Process Manager I\/O (PMIO) cabinets and remote I\/O files. To survive harsh processing facilities, the assembly features a specialized conformal coating layer protecting the circuitry against humidity, moisture, and corrosive atmospheric pollutants.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConformal Coating:\u003c\/strong\u003e Provides certified environmental protection against high humidity and active chemical gases, maintaining electrical insulation integrity over long operational lifespans.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eI\/O Link Extension:\u003c\/strong\u003e Extends communication distances for standard PMIO links, allowing flexible field placement of I\/O cabinets.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRedundancy Compatible:\u003c\/strong\u003e Engineered to function in matched pairs to ensure high-availability control system topologies without a single point of failure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE Compliant Design:\u003c\/strong\u003e Designed and manufactured to meet modern European electromagnetic compatibility (EMC) and electrical safety directives.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eHoneywell TDC 3000 and Experion PKS PMIO architectures.\u003c\/li\u003e\n  \u003cli\u003eRemote physical expansion of Honeywell High-Performance Process Manager (HPM) systems.\u003c\/li\u003e\n  \u003cli\u003eEnvironments with ISA Class G3 harshness levels, such as petrochemical plants, chemical refineries, and pulp and paper mills.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eHoneywell\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePart Number \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e51304419-150\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMC-IOLX02\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eStandard I\/O Link Extender Card\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eConformal Coating\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eYes (Fully coated assembly)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCE Compliance\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eYes (Compliant)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCompatibility\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eHoneywell TDC 3000 \/ Experion PKS PMIO Carriers\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePackaging Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e310 mm x 240 mm x 50 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe CE-compliant 51304419-150 directly replaces older, non-CE compliant variations of the MC-IOLX02 module line. Ensure that all redundant link extender pairs feature matching firmware\/revision levels to avoid signal synchronization or communication dropouts during failover events.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eIn older HPM installations, improper routing of coax and fiber cables associated with link extenders can cause signal attenuation. Ensure that bend radii for communication media conform to Honeywell site planning guidelines to prevent packet loss. The MC-IOLX02 must reside on compatible PMIO carriers designed to support the specific current draw of the extender circuitry.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDuring commissioning, verify the grounding path of the I\/O Link shields. High common-mode noise on the link cabling can degrade communication speed and trigger redundant switchovers. Check the integrity of the coaxial connectors using an appropriate RF power or network analyzer if intermittent Link Error flags occur in the Experion System Status Display.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem; border-radius: 4px;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 5px 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0; font-size: 0.95rem;\"\u003eAlways isolate power from the card carrier before inserting or extracting the 51304419-150 card. Hot-plugging in non-rated environments can cause electrical arcs, transient damage to adjacent modules, and CPU faults.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003ePerform a controlled shutdown of the target I\/O Link branch if a redundant pair is not actively available to handle field operations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWear a calibrated ESD wrist strap grounded directly to the cabinet framework before removing the card from its protective packaging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eAlign the card with the carrier guide rails and push firmly until the card connector is completely seated and locked into the backplane.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003ePower up the carrier, observe the card initialization LED diagnostic sequence, and verify correct system diagnostic status via the Experion PKS console.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705566032235,"sku":"51304419-150","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/51304419-150-2xetwawmks3_20fac15b-5e5b-4af3-b435-380bf78aa7c1.jpg?v=1766649977","url":"https:\/\/www.plcprotech.com\/fa\/products\/honeywell-51304419-150-mc-iolx02-standard-i-o-link-extender-card","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}