{"product_id":"honeywell-cc-pcf901-series-c-control-firewall-module","title":"Honeywell CC-PCF901 Series C Control Firewall Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Managing Fault Tolerant Ethernet (FTE) traffic within the Experion PKS control network requires robust physical layer routing, which is exactly what the Honeywell CC-PCF901 Control Firewall Module delivers. This industrial hardware module acts as a dedicated security and routing interface, distributing critical FTE cabling directly to multiple Series C Fieldbus Interface Modules (FIMs) and internal cabinet network nodes. By implementing the Honeywell CC-PCF901 within your control topology, you establish a reliable hardware-level defense against network disturbances, isolating critical C300 Controllers and associated Series C I\/O modules from external network traffic anomalies.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFTE Distribution:\u003c\/strong\u003e Provides clean, structured distribution of Fault Tolerant Ethernet connections inside the cabinet.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eController Protection:\u003c\/strong\u003e Safeguards sensitive Honeywell C300 controllers and Series C I\/O modules from broadcast storms and network congestion.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIOTA Mounting:\u003c\/strong\u003e Direct installation onto the CF9 Input\/Output Termination Assembly (IOTA) simplifies cabling and cabinet architecture.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Hardening:\u003c\/strong\u003e Conformal coated construction protects internal circuitry against harsh process environments and particulate contamination.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLow Power Footprint:\u003c\/strong\u003e Highly efficient internal power conversion minimizes cabinet thermal loading and auxiliary power draw.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eHoneywell Experion PKS process automation environments.\u003c\/li\u003e\n  \u003cli\u003eIn-cabinet FTE network isolation and signal distribution hubs.\u003c\/li\u003e\n  \u003cli\u003ePetrochemical, power generation, and critical refining control architectures.\u003c\/li\u003e\n  \u003cli\u003eDistributed Control System (DCS) cybersecurity hardening configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eHoneywell\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCC-PCF901\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSeries Name\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eExperion PKS Series C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eControl Firewall Module (CFM)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eNominal Supply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e24 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCurrent Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.112 A (112 mA) @ 24 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCompatible IOTA Base\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCC-TCF901 (CF9 Termination Assembly)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eNetwork Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eFault Tolerant Ethernet (FTE)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eConformal Coating\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eStandard G3 compliance for harsh environments\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0 to 60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e25.4 x 15.2 x 7.6 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The CC-PCF901 is designed exclusively for Honeywell Series C architecture. It cannot be used interchangeably with legacy Series A or PMIO hardware assemblies. Ensure that your current Experion control software version supports the CF9 IOTA hardware before deploying replacement components.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Always verify the integrity of the ground path on the CC-TCF901 IOTA prior to snapping the module onto the base. Faulty or high-impedance cabinet grounding can result in erratic FTE signal degradation or hardware-level communication dropouts. Use high-quality shielded Ethernet cables for external FTE lines routing to the IOTA structure.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cspan style=\"color: #9b2c2c;\"\u003e\n    Before performing any maintenance or swapping the control module, verify that the 24VDC system supply is completely powered down. Hot-swapping network components without system preparation can lead to electrostatic discharge damage or trigger unexpected controller switchovers.\n  \u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: inline-flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003ePower down the relevant sector of the cabinet or the targeted IOTA base power feed.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: inline-flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eMount the CC-PCF901 module securely onto the CC-TCF901 (CF9) Input\/Output Termination Assembly until the latch clicks.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: inline-flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eConnect the FTE Yellow and FTE Green networks directly to their respective designated RJ45 physical ports.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1.5rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: inline-flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eRe-energize the assembly and verify the internal network link diagnostic LEDs display normal operational statuses.\u003c\/span\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705571766635,"sku":"CC-PCF901","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cc-pcf901-1ocqbflwjue_ad2983e9-12f1-4c14-85ca-76d2e709027e.jpg?v=1766650189","url":"https:\/\/www.plcprotech.com\/fa\/products\/honeywell-cc-pcf901-series-c-control-firewall-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}