{"product_id":"honeywell-cc-pwrr01-c300-redundant-power-supply-module","title":"Honeywell CC-PWRR01 C300 Redundant Power Supply Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDelivering regulated, highly reliable power distribution within the Experion C300 controller subsystem, the \u003cstrong\u003eHoneywell CC-PWRR01\u003c\/strong\u003e functions as a dual-channel redundant power source designed to protect critical process control loops from input line failures. This module integrates directly into the Series C power carrier assemblies, allowing for seamless load-sharing, active diode auctioning, and uninterrupted power handovers. Engineered specifically to meet the high-availability demands of modern continuous process environments, the \u003cstrong\u003eHoneywell CC-PWRR01\u003c\/strong\u003e stabilizes system voltages, filters electromagnetic interference, and provides real-time diagnostic status feedback directly to the controller architecture.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eActive Redundant Load-Sharing:\u003c\/strong\u003e Seamlessly balances the current demand between paired power modules to extend component lifecycle and ensure zero-millisecond failover.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHot-Swappable Architecture:\u003c\/strong\u003e Permits safe removal and replacement of a faulted power supply module while the process system remains fully energized.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDiagnostic Status Indication:\u003c\/strong\u003e Front-panel LEDs provide immediate, clear visual states of input power viability, output regulation, and over-temperature faults.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Diode Auctioning:\u003c\/strong\u003e Eliminates the risk of back-feeding or circuit disruption in the event of an internal component short-circuit.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Industrial Filtering:\u003c\/strong\u003e Built-in transient voltage surge suppression (TVSS) shields downstream C300 controllers and Series C I\/O modules from grid irregularities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003ePetrochemical refining and high-availability chemical synthesis plants.\u003c\/li\u003e\n  \u003cli\u003eBase-load and peak-generation thermal and combined-cycle power facilities.\u003c\/li\u003e\n  \u003cli\u003eContinuous process pulp, paper, and metallurgy control networks.\u003c\/li\u003e\n  \u003cli\u003eOffshore oil platform Emergency Shutdown (ESD) and Fire \u0026amp; Gas (F\u0026amp;G) systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"text-align: left; padding: 10px; border-bottom: 2px solid #2d3748; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; border-bottom: 2px solid #2d3748; font-weight: bold;\"\u003eValue \/ Specification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border-bottom: 1px solid #e2e8f0; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border-bottom: 1px solid #e2e8f0;\"\u003eHoneywell\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border-bottom: 1px solid #e2e8f0; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border-bottom: 1px solid #e2e8f0;\"\u003eCC-PWRR01\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border-bottom: 1px solid #e2e8f0; font-weight: bold;\"\u003eSystem Compatibility\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border-bottom: 1px solid #e2e8f0;\"\u003eExperion C300 \/ Series C I\/O\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border-bottom: 1px solid #e2e8f0; font-weight: bold;\"\u003eOutput Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border-bottom: 1px solid #e2e8f0;\"\u003e24 VDC nominal\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border-bottom: 1px solid #e2e8f0; font-weight: bold;\"\u003eConfiguration\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border-bottom: 1px solid #e2e8f0;\"\u003eRedundant (requires matching module on compatible carrier)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border-bottom: 1px solid #e2e8f0; font-weight: bold;\"\u003eCooling Method\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border-bottom: 1px solid #e2e8f0;\"\u003eNatural convection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border-bottom: 1px solid #e2e8f0; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border-bottom: 1px solid #e2e8f0;\"\u003e0 to 60 degC (32 to 140 degF)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border-bottom: 1px solid #e2e8f0; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border-bottom: 1px solid #e2e8f0;\"\u003e-40 to 85 degC (-40 to 185 degF)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border-bottom: 1px solid #e2e8f0; font-weight: bold;\"\u003eRelative Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border-bottom: 1px solid #e2e8f0;\"\u003e5% to 95% non-condensing\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border-bottom: 1px solid #e2e8f0; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border-bottom: 1px solid #e2e8f0;\"\u003eUnited States \/ Global OEM sites\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border-bottom: 1px solid #e2e8f0; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border-bottom: 1px solid #e2e8f0;\"\u003e2.00 kg (4.41 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border-bottom: 1px solid #e2e8f0; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border-bottom: 1px solid #e2e8f0;\"\u003e250 x 180 x 120 mm (9.84 x 7.09 x 4.72 in)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"text-align: left; padding: 10px; border-bottom: 2px solid #2d3748; font-weight: bold;\"\u003eConnection Point\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; border-bottom: 2px solid #2d3748; font-weight: bold;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border-bottom: 1px solid #e2e8f0; font-weight: bold;\"\u003eBackplane Connector\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border-bottom: 1px solid #e2e8f0;\"\u003eHigh-current blind-mate interface interfacing directly with the power carrier bus bars.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border-bottom: 1px solid #e2e8f0; font-weight: bold;\"\u003eStatus LED Array\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border-bottom: 1px solid #e2e8f0;\"\u003eVisual indicators for Input OK (Green), Output OK (Green), and Module Fault\/Over-Temp (Red).\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe CC-PWRR01 is designed specifically for insertion into the CC-PWRB01 (or equivalent) redundant power carrier. When performing system upgrades or migrations from legacy Experion platforms, verify that your existing carrier backplane is rated to accept Series C Form-Factor modules, as keying pins prevent physical mismating with non-compatible I\/O racks.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo guarantee optimal MTBF, maintain at least 50mm of clear space above and below the power carrier assembly to allow unobstructed convective airflow. In highly enclosed or non-ventilated field cabinets, thermal concentration can cause premature aging of the internal electrolytic capacitors. Always implement external ambient monitoring within the cabinet to ensure temperatures do not exceed the 60 degC threshold.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen bringing a redundant pair online, energize the primary and secondary power sources from isolated feed breakers. This layout ensures that an upstream breaker trip on Feed A does not compromise Feed B. Utilize the dry-contact alarm terminal block on the redundant carrier to route power fail status signals back to your diagnostic alarm logs in Experion PKS.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Ensure all incoming primary AC or DC power feeds are locked out, tagged out, and verified de-energized prior to installing, removing, or wiring any power carrier components. Working on live terminations poses severe flashover, shock, and equipment damage risks.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.2rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 12px; flex-shrink: 0; font-weight: bold;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748; padding-top: 2px;\"\u003eMount the compatible Series C Redundant Power Carrier securely to the standard 35mm DIN rail or cabinet backplate using rugged grounding screws.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.2rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 12px; flex-shrink: 0; font-weight: bold;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748; padding-top: 2px;\"\u003eAlign the CC-PWRR01 module with the dedicated slot guides on the carrier card. Slide the unit firmly until the blind-mate backplane connectors fully seat and the retaining mechanism clicks into place.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.2rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 12px; flex-shrink: 0; font-weight: bold;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748; padding-top: 2px;\"\u003eConnect your input feed wires to the respective terminal terminals on the carrier block, verifying torque settings match Honeywell installation specs. Do not over-tighten.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 12px; flex-shrink: 0; font-weight: bold;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748; padding-top: 2px;\"\u003eApply power to Feed A and verify the corresponding LED lights up Green. Repeat for Feed B, ensuring both modules operate in active load-sharing configuration.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52679482704235,"sku":"CC-PWRR01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/CC-PWRR01-fe2ih4bac11_bef98e84-2e8d-4bd4-812b-8060c978086a.jpg?v=1765958506","url":"https:\/\/www.plcprotech.com\/fa\/products\/honeywell-cc-pwrr01-c300-redundant-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}