{"product_id":"honeywell-tk-ccr014-c200-redundant-controlnet-interface-module","title":"Honeywell TK-CCR014 C200 Redundant ControlNet Interface Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTK-CCR014\u003c\/strong\u003e is a high-reliability communication routing component operating as a \u003cstrong\u003eRedundant Net Interface Module\u003c\/strong\u003e within the Honeywell C200 and Experion distributed control system (DCS) architectures. This interface module provides critical dual-channel ControlNet network linking capabilities, acting as the deterministic communication bridge between primary processing chassis networks and remote I\/O chassis blocks. Built with a redundant network transceiver layout, the unit monitors connection path health in real time and automatically executes sub-millisecond switchovers to the backup channel if a media interruption occurs. This fault-tolerant structure guarantees steady parameters, safety logic execution, and uninterrupted diagnostic telemetry across centralized process networks.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRedundant dual-channel interface supporting seamless network media switchovers.\u003c\/li\u003e\n\u003cli\u003eHighly deterministic ControlNet protocol management for real-time tracking.\u003c\/li\u003e\n\u003cli\u003eStandardized form factor for direct rack integration into standard C200 slots.\u003c\/li\u003e\n\u003cli\u003eIntegrated front-panel status lights for instant diagnostic and link health reporting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRedundant network tracking between master C200 processors and remote I\/O racks.\u003c\/li\u003e\n\u003cli\u003eHigh-availability communication bridging in distributed control systems (DCS).\u003c\/li\u003e\n\u003cli\u003eSupervisory network isolation in chemical manufacturing and petroleum refineries.\u003c\/li\u003e\n\u003cli\u003eReal-time network infrastructure coordination inside critical power generation utility loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTK-CCR014\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRedundant Net Interface Module (ControlNet FIM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eC200 \/ Experion System Chassis I\/O (CIOM-A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUnited States \/ Global Operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocol\u003c\/td\u003e\n\u003ctd\u003eControlNet (Redundant Media Support)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch3\u003eGrounding and Shielding\u003c\/h3\u003e\n\u003cp\u003eVerify that the hosting C200 equipment rack is bonded cleanly to the main facility instrument grounding network using a low-impedance copper wire. Communication trunk coax and tap cables must follow standardized network installation procedures, ensuring that the shield integrity is maintained across the segments to suppress high-frequency radio interference.\u003c\/p\u003e\n\u003ch3\u003eHandling and ESD Protection\u003c\/h3\u003e\n\u003cp\u003eThe internal communication processors are highly sensitive to electrostatic discharge (ESD). Field engineers must wear an approved, snug-fitting static-dissipative wrist strap connected to a verified ground prior to unboxing the module, shifting node addresses, or sliding the card into the chassis backplane.\u003c\/p\u003e\n\u003ch3\u003eAlignment and Insertion\u003c\/h3\u003e\n\u003cp\u003eAlign the edges of the module's circuit board with the molded plastic track guides of the local slot. Slide the unit inward firmly until the rear pins match and fully engage the backplane connector. Secure the mechanical faceplate screws to protect the communication interface from continuous industrial panel vibration.\u003c\/p\u003e\n\u003ch3\u003eNetwork Cable Routing\u003c\/h3\u003e\n\u003cp\u003eMaintain a safe physical clearance between the network coax cables and high-voltage AC mains lines or heavy motor starters. Keeping the network lines inside dedicated, isolated conduit trays minimizes magnetic fields from introducing data errors or transmission delays on the control link.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the core purpose of this interface module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt provides a redundant, deterministic ControlNet link to connect process controllers with distributed remote I\/O chassis assemblies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module react if one of the network cables is broken?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe internal redundant interface immediately switches data traffic to the secondary channel without dropping communication frames or resetting the rack status.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this device compatible with standard Honeywell C200 systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it utilizes the precise physical form factor required to fit into standard CIOM-A rack slots.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the net unboxed weight of this communication hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe standalone unboxed module has an exact physical weight of 0.45 Kg.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat do the front-panel indicator lights signify?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe LEDs provide real-time status diagnostics regarding module health, backplane synchronization, and the operational link state of both channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this hardware require distinct configuration settings?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, hardware node switches or software configuration tools must be set to assign the module its correct address on the network.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of cabling is used to hook up this network module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt connects to standard industrial ControlNet network layouts using coaxial media taps and BNC-style locking terminators.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this component run as an independent loop controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, it is a dedicated network communications interface designed to route data packages between controllers and peripheral racks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat precautions should be followed concerning static discharge during card replacement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlways practice correct ESD guidelines, utilizing grounded bags and active wrist straps whenever handling the module out of the chassis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the total package mass when packed for standard freight delivery?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe gross shipping weight of the module and its protective industrial box is specified at 2 Kg.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705321484651,"sku":"TK-CCR014","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/TK-CCR014-oe2lylzek5c_9d5c7312-9fa5-4736-a687-0b0c8c3f46ba.jpg?v=1766639778","url":"https:\/\/www.plcprotech.com\/fa\/products\/honeywell-tk-ccr014-c200-redundant-controlnet-interface-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}