{"product_id":"lenze-e82ev371-2c200-8200-vector-variable-frequency-drive","title":"Lenze E82EV371_2C200 8200 Vector Variable Frequency Drive","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Engineered for precise motor speed control in space-constrained automation panels, the \u003cstrong\u003eLenze E82EV371_2C200\u003c\/strong\u003e is a 0.37 kW basic frequency inverter belonging to the legacy \u003cstrong\u003e8200 Vector\u003c\/strong\u003e series. This single-phase unit provides reliable vector control performance for standard three-phase asynchronous motors, offering a compact footprint and modular adaptability for industrial machinery.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSingle-Phase Input:\u003c\/strong\u003e Optimized for 1-phase AC mains operation, making it suitable for localized or utility-level industrial power grids.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFilterless Design:\u003c\/strong\u003e Basic unit variant supplied without an integrated EMC filter, allowing custom external filtering configurations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular Architecture:\u003c\/strong\u003e Compatible with pluggable 8200-series function modules for communication and expanded I\/O.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Torque Performance:\u003c\/strong\u003e Vector control capability ensures stable torque output even at low rotational speeds.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial Handling:\u003c\/strong\u003e Conveyor belts, sorting tables, and small feeder drives.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFluid Control:\u003c\/strong\u003e Small centrifugal pumps and localized ventilation fans.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackaging Machinery:\u003c\/strong\u003e Auxiliary axes, labeling machines, and wrapping systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMachine Tools:\u003c\/strong\u003e Speed regulation for small spindle drives and tool feeds.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eLenze\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eE82EV371_2C200\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eAlternative Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eE82EV371K2C200\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e8200-series (8200 Vector)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eVariable Frequency Drive (VFD)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eRated Power\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.37 kW\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInput Phases\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1-Phase (1~ AC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eIntegrated EMC Filter\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eNone (Variant without integrated filter)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePhase-Out (Legacy support available)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e6.10 x 12.70 x 14.00 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.50 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e85044095\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eTerminal Designation\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eL1, N\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSingle-Phase AC Mains Input Connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eU, V, W\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3-Phase Motor Output Connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePE\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eProtective Earth Grounding Terminal\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  \u003cstrong\u003eAlternative Models \u0026amp; Compatibility:\u003c\/strong\u003e The E82EV371_2C200 is functionally identical to the model listed under the SKU E82EV371K2C200, where the \"K\" designates the decimal placement for the 0.37 kW power rating. When replacing older 8200 series units, ensure that any existing pluggable communication modules (such as LECOM or CANopen) are carefully migrated to the new basic unit, as these modules are hot-swappable but require proper parameter mapping upon first power-up.\n\u003c\/p\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  \u003cstrong\u003eApplication Pitfalls \u0026amp; Engineering Notes:\u003c\/strong\u003e Because this specific variant does not feature an integrated EMC filter, it is highly susceptible to emitting high-frequency electromagnetic interference back into the mains supply. If installing this unit in environments sensitive to electrical noise (such as laboratory or light industrial zones), an external mains filter must be wired in series with the input power lines.\n\u003c\/p\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong\u003eCommissioning \u0026amp; Wiring Tips:\u003c\/strong\u003e Ensure that the motor cable is shielded and grounded at both ends with low-impedance connections. When configuring parameters via the keypad or Global Drive Control (GDC) software, verify that the motor nameplate data matches the drive's default motor parameters to prevent overcurrent faults (OC1) during initial acceleration ramps.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; border-radius: 4px;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    Ensure all input power sources are completely de-energized and locked out before attempting installation or wiring. Wait at least 5 minutes after disconnecting power to allow internal DC bus capacitors to discharge to safe voltage levels (less than 50 VDC) before touching any terminals.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; color: #2d3748; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; flex-shrink: 0; font-weight: bold;\"\u003e1\u003c\/div\u003e\n    \u003cdiv\u003eMount the drive vertically on a flat, vibration-free surface inside an IP54 or appropriate industrial enclosure to protect against dust and moisture ingress.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; flex-shrink: 0; font-weight: bold;\"\u003e2\u003c\/div\u003e\n    \u003cdiv\u003eMaintain a minimum clearance of 100 mm above and below the unit to facilitate natural convection cooling and prevent thermal derating.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; flex-shrink: 0; font-weight: bold;\"\u003e3\u003c\/div\u003e\n    \u003cdiv\u003eConnect the single-phase AC mains supply to terminals L1 and N, ensuring correct fuse ratings are applied in accordance with local electrical codes.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; flex-shrink: 0; font-weight: bold;\"\u003e4\u003c\/div\u003e\n    \u003cdiv\u003eWire the 3-phase motor cables to terminals U, V, and W, ensuring the protective ground (PE) is securely bonded to the main system ground bus.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105052713323,"sku":"E82EV371_2C200","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e82ev371-2c200-10np2jc2xya.png?v=1776235866","url":"https:\/\/www.plcprotech.com\/fa\/products\/lenze-e82ev371-2c200-8200-vector-variable-frequency-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}