{"product_id":"mitsubishi-electric-q64tcrtn-melsec-q-series-temperature-control-module","title":"Mitsubishi Electric Q64TCRTN MELSEC-Q Series Temperature Control Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003ePrecision thermal regulation in automated systems requires reliable, high-speed feedback and control. The \u003cstrong\u003eMitsubishi Electric Q64TCRTN\u003c\/strong\u003e is a high-performance, 4-channel \u003cstrong\u003etemperature control module\u003c\/strong\u003e designed for seamless integration with the MELSEC-Q Series PLC platform. Operating as an intelligent function module, this unit directly interfaces with Pt100 and JPt100 resistance temperature detectors (RTDs) to deliver accurate monitoring and closed-loop PID control without placing overhead on the main CPU.\u003c\/p\u003e\n\n\u003cp\u003eEquipped with four independent input channels and corresponding transistor outputs, the \u003cstrong\u003eQ64TCRTN\u003c\/strong\u003e utilizes an advanced auto-tuning PID algorithm to maintain stable process variables. This makes it highly compatible with demanding thermal management systems in plastics extrusion, packaging machinery, chemical processing, and environmental chambers. Its isolated architecture ensures robust protection against electrical noise and ground loops in harsh industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMulti-Channel Input:\u003c\/strong\u003e Supports 4 independent temperature measurement channels using standard Pt100 or JPt100 RTD sensors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Control Modes:\u003c\/strong\u003e Configurable for PID control (with auto-tuning), ON\/OFF pulse control, or direct 2-position control.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Speed Processing:\u003c\/strong\u003e Fast 500 ms sampling cycle across all 4 active channels ensures responsive control actions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Insulation:\u003c\/strong\u003e Built-in transformer isolation between the input terminals, the sequencer power supply, and individual input channels.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDisconnection Safety:\u003c\/strong\u003e Features automatic upscale processing in the event of sensor input disconnection to protect downstream hardware.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePlastic extrusion and injection molding temperature control.\u003c\/li\u003e\n  \u003cli\u003eFood processing and packaging heat-seal systems.\u003c\/li\u003e\n  \u003cli\u003eChemical and pharmaceutical reactor thermal regulation.\u003c\/li\u003e\n  \u003cli\u003eSemiconductor manufacturing cleanroom climate control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMitsubishi Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eQ64TCRTN\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMELSEC-Q\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTemperature Control Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Input Channels\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4 channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCompatible Sensors\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePt100, JPt100 RTDs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasurement Accuracy (25 +\/- 5 degC)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFull Scale x (+\/- 0.3%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasurement Accuracy (0 to 55 degC)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFull Scale x (+\/- 0.7%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSampling Cycle\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500 ms \/ 4 channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 M ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eControl Output Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTransistor (ON\/OFF pulse)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Load Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10 to 30 VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Load Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.1 A per point, 0.4 A per common\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Inrush Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.4 A (10 ms)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 ms or less (OFF to ON \/ ON to OFF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInsulation Method\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTransformer insulation (between inputs and sequencer power\/channels)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWithstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAC 500 V for 1 minute\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDC 500 V, 20 M ohm or more\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eExternal Connections\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e18-point screw terminal block (M3 screws)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eI\/O Points Occupied\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e16 points (Intelligent function module)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInternal Current Consumption (5 VDC)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.29 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e98 mm x 27.4 mm x 112 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.20 Kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e Securely insert the module into a standard MELSEC-Q series base unit, ensuring the module fixing hook is fully engaged.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Wiring:\u003c\/strong\u003e Use M3 crimp terminals for all connections to the 18-point terminal block. Tighten terminal screws to the recommended torque limit of 0.42 to 0.58 N-m.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNoise Mitigation:\u003c\/strong\u003e Route sensor input wiring separately from high-voltage AC power lines and motor drives to prevent electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Connect the shield wire of the RTD cable to the designated ground terminal on the module or the panel enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102147567979,"sku":"Q64TCRTN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/Q64TCRTN-bwx43iuccpa.png?v=1776137956","url":"https:\/\/www.plcprotech.com\/fa\/products\/mitsubishi-electric-q64tcrtn-melsec-q-series-temperature-control-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}