{"product_id":"mitsubishi-electric-ry42nt2p-melsec-iq-r-transistor-output-module","title":"ماژول خروجی ترانزیستوری Mitsubishi Electric RY42NT2P MELSEC iQ-R  ","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEngineered for high-density industrial control architectures, this 64-point digital output module provides high-speed, reliable transistor switching within the MELSEC iQ-R Series PLC platform. The \u003cstrong\u003eMitsubishi Electric RY42NT2P\u003c\/strong\u003e acts as a robust NPN sink-type transistor interface, featuring built-in overcurrent and thermal overload protection to shield critical field circuits and internal hardware from electrical faults. Its ultra-compact dual 40-pin connector layout maximizes I\/O density in heavy-duty automation panels while maintaining precise response times.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Density Output Channel Count:\u003c\/strong\u003e 64 digital outputs consolidated into a single-slot footprint.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSink Type (NPN) Transistor Logic:\u003c\/strong\u003e Designed for standard low-side industrial switching.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Protection (\"P\" Suffix):\u003c\/strong\u003e Safeguards active circuits against field-side short circuits and thermal overloads.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFast Response Times:\u003c\/strong\u003e Microsecond-range switching latency ensures accurate execution of time-critical control loops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual 40-Pin Connector Interface:\u003c\/strong\u003e Reliable connection point for dense wiring harnesses and pre-assembled cable modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eControl of pneumatic and hydraulic solenoid valve manifolds.\u003c\/li\u003e\n  \u003cli\u003eInterfacing with external solid-state relays (SSRs) and auxiliary contactors.\u003c\/li\u003e\n  \u003cli\u003eMulti-axis robotic cells and CNC automated tool changers.\u003c\/li\u003e\n  \u003cli\u003eHigh-density logic transmission to distributed sensor-actuator hubs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.75rem;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eMitsubishi Electric\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRY42NT2P\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePLC Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eMELSEC iQ-R\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eTransistor Output Module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNumber of Outputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e64 points\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOutput Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eTransistor (Sink \/ NPN)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eRated Load Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e12 to 24 VDC (+10% \/ -15%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eMax. Load Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.2A per point; 1.6A per common terminal;\"\u003e0.2 A per point, 1.6 A per common\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eResponse Time (Off to On)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e\u0026lt;= 1.0 ms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eResponse Time (On to Off)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e\u0026lt;= 1.5 ms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eInternal Current Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e110 mA (5 VDC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePhysical Connection\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eDual 40-pin connectors\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProtection Functions\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eOvercurrent protection, thermal shutdown protection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0.13 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1.50 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eJapan\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen migrating legacy systems or processing system upgrades, note that the \u003cstrong\u003eRY42NT2P\u003c\/strong\u003e replaces older non-protected 64-point output modules. The \"P\" version incorporates hardware-level self-resetting protection circuits, which might slightly alter thermal dissipation profiles in extremely cramped, unventilated enclosures. Confirm your firmware configuration in GX Works3 matches the exact \"P\" designation to enable diagnostics for channel-specific overcurrent flags.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhile the module is rated for 0.2 A per point, the aggregate current limit of 1.6 A per common group must not be exceeded. In installations running simultaneous high-duty inductive loads, such as large solenoids or direct-drive miniature relays, external flyback\/freewheeling diodes must be placed across the loads. Failure to suppress inductive kickback will lead to premature fatigue of the internal output transistors and transient noise injection into the PLC backplane.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1.5rem;\"\u003eAlways utilize standard pre-assembled 40-pin ribbon cable systems or dedicated terminal block conversion modules (e.g., terminal breakout boards) to eliminate manual connector-soldering errors. To minimize electromagnetic interference (EMI), route your 24 VDC field power supply lines in pathways separate from high-power AC motor drives and motor cabling.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Prior to installing, removing, or wiring any module, isolate all external power sources feeding the PLC chassis and field circuits. Failure to de-energize the system completely can result in permanent hardware damage, unexpected machine movement, or physical injury.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 1.5rem; height: 1.5rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eAlign the module's lower hook with the slot on the base unit, making sure the connector pins are clear of obstruction.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 1.5rem; height: 1.5rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003ePush the module firmly toward the base unit until it clicks securely into place, ensuring the module mounting lever engages properly.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 1.5rem; height: 1.5rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eTighten the module fixing screw (if used in high-vibration environments) to the specified OEM torque limits.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 1.5rem; height: 1.5rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the 40-pin terminal harnesses securely, ensuring the locking mechanisms click into position to prevent loose physical contacts.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102153564523,"sku":"RY42NT2P","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ry42nt2p-crypkwidtyv.png?v=1776138022","url":"https:\/\/www.plcprotech.com\/fa\/products\/mitsubishi-electric-ry42nt2p-melsec-iq-r-transistor-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}