{"product_id":"omron-3g3mx2-a4004-zv1-mx2-series-multi-function-compact-inverter","title":"Omron 3G3MX2-A4004-ZV1 MX2 Series Multi-Function Compact Inverter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Engineered to deliver exceptional vector control and dynamic performance for industrial motors, the \u003cstrong\u003eOmron 3G3MX2-A4004-ZV1\u003c\/strong\u003e is a highly integrated, 3-phase 400 V AC variable frequency drive from the \u003cstrong\u003eMX2 Series\u003c\/strong\u003e. With a rated capacity of 0.4 kW, this multi-function compact inverter is optimized for applications requiring high starting torque, accurate speed regulation, and functional safety integration directly within the drive control loop.\n\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual Rating Support:\u003c\/strong\u003e Optimized for heavy-duty applications requiring up to 200% starting torque at 0.5 Hz.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Functional Safety:\u003c\/strong\u003e Built-in dual safety inputs conform to ISO 13849-1 Cat 3 \/ PLd without requiring external contactors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePermanent Magnet Motor Control:\u003c\/strong\u003e Compatible with both standard induction motors (IM) and permanent magnet synchronous motors (PM).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModbus RTU Communication:\u003c\/strong\u003e Embedded RS-485 serial communication port supports seamless field integration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSide-by-Side Mounting:\u003c\/strong\u003e Space-saving chassis design allows compact panel layout configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eHigh-torque material handling conveyors and sorting lines.\u003c\/li\u003e\n  \u003cli\u003eIndustrial packaging systems with rapid start\/stop cycles.\u003c\/li\u003e\n  \u003cli\u003ePumping and ventilation systems utilizing permanent magnet motor technology.\u003c\/li\u003e\n  \u003cli\u003eAutomated assembly systems requiring integrated safety functions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3G3MX2-A4004-ZV1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMX2 Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eInput Voltage Class\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3-phase 380 to 480 V AC (+10% \/ -15%), 50\/60 Hz (+\/- 5%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eApplicable Motor Capacity (CT)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.4 kW (Constant Torque)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOutput Rated Current (CT)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1.8 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eEnclosure Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIP20 \/ Panel-mounting (IP10 min.)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eControl Method\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePhase-controlled sinusoidal PWM (V\/f or Open-loop vector)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eBuilt-in Communication\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eModbus RTU (RS-485)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSafety Standards\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eISO 13849-1 Cat 3 \/ PLd, IEC 60204-1 Stop Category 0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-10 to +50 degC (no freezing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eUnit Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1.6 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e4.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eTerminal Symbol\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eFunctional Description\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eR\/L1, S\/L2, T\/L3\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMain power supply inputs (3-phase 400 V AC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eU\/T1, V\/T2, W\/T3\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eInverter output terminals connected to the AC motor\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePD\/+, P\/+\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eExternal DC reactor terminal (remove jumper to install)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eP\/+, RB\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBraking resistor connection terminals\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eS1, S2, G\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSafety function terminals (STO - Safe Torque Off inputs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The \"-ZV1\" suffix indicates a multi-function firmware revision optimized for expanded parameters and enhanced PM motor synchronization profiles. When replacing standard or older MX2 series non-ZV1 units, ensure to backup parameter sets using CX-Drive software, as certain memory maps may require scaling or verification during conversion.\n\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  When operating in enclosed panels under sustained high-torque conditions, thermal load may trigger an E05 overload fault code. Side-by-side mounting is fully supported, but a derating of 10% in output current is recommended if ambient temperatures exceed 40 degC inside the enclosure. Always ensure the internal cooling fan duct remains free of debris.\n\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  For compliant safety loop deployment (STO), ensure the factory-installed shorting bar between S1, S2, and G is completely removed before connecting to your safety relay module or light curtain controller. If utilizing long motor cable runs exceeding 50 meters, an output AC dV\/dT filter must be installed to prevent high voltage spikes from degrading the motor winding insulation.\n\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING: HIGH VOLTAGE HAZARD\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    Isolate all primary AC power feeds before commencing mechanical installation or terminal wiring. Internal storage capacitors retain lethal charges. Wait a minimum of 10 minutes after disconnecting input power and verify that the charge indicator LED on the front panel is completely off before servicing terminal blocks.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 30px; height: 30px; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eMount the inverter vertically on a flat, non-flammable surface inside a dust-free control cabinet using M4 mounting hardware.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 30px; height: 30px; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eEnsure minimum clearances are maintained: at least 10 cm above and below the drive housing to ensure unrestricted convection cooling.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 30px; height: 30px; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eConnect the protective earth terminal (Ground) to a low-impedance master grounding bar before wiring any primary input power terminals.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 30px; height: 30px; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eWire the R\/L1, S\/L2, and T\/L3 incoming power leads using shielded wire, terminating the shield grounding clamps correctly to mitigate electromagnetic interference (EMI).\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077899837803,"sku":"3G3MX2-A4004-ZV1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3g3mx2-a4004-zv1-2hdnudygmb5.png?v=1775733436","url":"https:\/\/www.plcprotech.com\/fa\/products\/omron-3g3mx2-a4004-zv1-mx2-series-multi-function-compact-inverter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}