{"product_id":"omron-ns5-sq10b-ecv2-ns-series-interactive-display-panel","title":"Omron NS5-SQ10B-ECV2 NS Series Interactive Display Panel","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned to integrate directly into factory automation architectures, the \u003cstrong\u003eOmron NS5-SQ10B-ECV2\u003c\/strong\u003e serves as a high-reliability human-machine interface (HMI) for real-time process monitoring and control. This unit features a high-visibility 5.7-inch color TFT LCD display that ensures clear diagnostics and operator interaction in demanding industrial environments. Equipped with an upgraded LED backlight, this model provides consistent luminance and extended operational lifespan compared to legacy CCFL backlit versions. Configuration and screen design are managed seamlessly using the \u003cstrong\u003eCX-Designer\u003c\/strong\u003e support tool, allowing engineers to deploy complex graphical screens, alarm monitoring systems, and data logging functions rapidly.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eColor TFT LCD Screen:\u003c\/strong\u003e High-contrast display with a 320 x 240 dot matrix (QVGA) for precise visual representation of industrial schematics.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLED Backlighting:\u003c\/strong\u003e Long-life, energy-efficient backlight technology that eliminates thermal strain and premature dimming.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Programming Architecture:\u003c\/strong\u003e Fully compatible with CX-Designer for simplified tag database mapping and screen creation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial-Grade Enclosure:\u003c\/strong\u003e Durable black housing designed to withstand typical industrial pollutants and mechanical stress.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Communication Options:\u003c\/strong\u003e Built-in ports supporting point-to-point and multi-drop serial connections to PLCs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003ePackaging machinery control and diagnostics.\u003c\/li\u003e\n  \u003cli\u003eConveyor and material handling automation systems.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater municipal treatment monitoring.\u003c\/li\u003e\n  \u003cli\u003eAutomotive assembly cell terminal interfaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eSpecification Parameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eValue \/ Rating\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eNS5-SQ10B-ECV2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eDisplay Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eColor TFT LCD\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eResolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e320 x 240 dots (QVGA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eBacklight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eLED backlight\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSupport Tool\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCX-Designer\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eAmbient Operating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0 to 50 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCase Color\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBlack\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eRated Power Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e24 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e8.0 kg (including secure industrial packaging)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eInterface Port\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eFunctional Details\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSerial Port A (RS-232C)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e9-pin D-sub connector for PLC connection, host link, or NT Link protocols.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSerial Port B (RS-232C)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e9-pin D-sub connector for secondary controller communications or bar code readers.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eUSB Slave Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eType-B connector for high-speed project upload and download from CX-Designer.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePower Input Terminal\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e3-terminal block for 24 VDC supply and frame ground connection.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe \u003cstrong\u003eNS5-SQ10B-ECV2\u003c\/strong\u003e features an upgraded LED backlight assembly that replaces the older, obsolete CCFL backlight variants (such as the standard NS5-SQ10B-V2). This hardware iteration is fully backward-compatible. Existing screen software projects built for older V2 models can be transferred directly to the ECV2 unit via CX-Designer without database conversion, though updating the system program (firmware) version of the target panel to match the latest runtime version is highly recommended to prevent touchscreen coordinate offset issues.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen housing this display in enclosed control cabinets, ensure adequate passive convection ventilation. The panel is rated to operate up to 50 degC, but prolonged operation above 45 degC inside tight spaces alongside hot components like power supplies or motor drives can accelerate backlight decay. Keep a minimum 100 mm clearance around the rear chassis of the screen.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways run the 24 VDC power supply lines through a dedicated noise filter if the system is positioned near high-frequency inductive loads or variable frequency drives (VFDs). Connect the physical functional ground (FG) terminal directly to a low-resistance, single-point industrial earth ground to avoid static touch anomalies or communication packet losses on the RS-232C ports.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"margin: 0; font-weight: bold; color: #9b2c2c;\"\u003eCRITICAL WARNING:\u003c\/p\u003e\n  \u003cp style=\"margin: 0.5rem 0 0 0; color: #9b2c2c;\"\u003eBefore initiating panel cut-out, mounting, or electrical terminal wiring, fully de-energize the main control cabinet feed. Ensure the 24 VDC power supply is completely isolated. Verify the absence of residual charges on the terminal block lines to protect internal CMOS processing components from electrical overstress.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 0.75rem;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003ePrepare the panel enclosure using the official template cut-out dimensions for 5.7-inch NS5 HMI hardware (typically 184 mm wide x 131 mm high).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 0.75rem;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eEnsure the waterproof gasket is correctly seated in the groove around the HMI bezel before inserting the device to maintain IP65 protection ratings.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 0.75rem;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eInsert the mounting brackets (supplied) into the slots on the top and bottom of the HMI housing, then tighten the screws evenly to a recommended torque of 0.5 to 0.6 Nm to prevent casing distortion.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 0.75rem;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the 24 VDC power input cables (minimum wire gauge 2.0 mm2 or AWG 14 recommended) to the HMI power terminal blocks and ground the FG terminal properly.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077913600363,"sku":"NS5-SQ10B-ECV2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ns5-sq10b-ecv2-5nvf33srkht.png?v=1775733922","url":"https:\/\/www.plcprotech.com\/fa\/products\/omron-ns5-sq10b-ecv2-ns-series-interactive-display-panel","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}