{"product_id":"omron-s8jx-g10024cd-s8jx-switch-mode-power-supply","title":"Omron S8JX-G10024CD S8JX Switch Mode Power Supply","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProviding a highly stable DC power source for automated machinery, the \u003cstrong\u003eOmron S8JX-G10024CD\u003c\/strong\u003e is a DIN rail-mounted, covered switch-mode power supply rated at 100 W. This unit converts standard wide-range AC inputs to a regulated 24 VDC output, making it an essential component for powering PLCs, sensors, HMI panels, and industrial control circuits. Engineered with a compact footprint and integrated safety protections, the \u003cstrong\u003eS8JX-G10024CD\u003c\/strong\u003e ensures continuous uptime in harsh panel environments where space and thermal management are critical.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRugged Covered Design:\u003c\/strong\u003e Provides physical protection to internal components while mitigating the risk of accidental contact with live electrical terminals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUniversal AC Input Capability:\u003c\/strong\u003e Supports standard single-phase mains voltages without manual switching or configuration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Protections:\u003c\/strong\u003e Automatic recovery for overload conditions and clamp-style overvoltage protection guard connected field devices.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdjustable Output:\u003c\/strong\u003e Integrated front-panel potentiometer allows precise fine-tuning of output voltage to compensate for line drops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect DIN Rail Mounting:\u003c\/strong\u003e Factory-equipped with a robust DIN rail bracket for fast, tool-free installation in standard electrical enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Control Panels:\u003c\/strong\u003e Supplying clean 24 VDC control power to PLCs, I\/O modules, and safety relays.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackaging and Assembly Lines:\u003c\/strong\u003e Driving photoelectric sensors, inductive proximity switches, and small DC solenoids.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBuilding Automation:\u003c\/strong\u003e Powering HVAC controllers, monitoring systems, and local display panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eSpecification Parameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eValue \/ Detail\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eS8JX-G10024CD\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eS8JX Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePower Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e100 W\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eRated Input Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e100 to 240 VAC (Allowable range: 85 to 264 VAC, 50\/60 Hz)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOutput Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e24 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOutput Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e4.5 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eVoltage Adjustment Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-10% to +15% (via front panel V.ADJ)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOverload Protection\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e105% to 160% of rated current, inverted time delay, automatic reset\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOvervoltage Protection\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eYes, clamp-style shut-off\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMounting Configuration\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDIN Rail-mounting\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eEnclosure Configuration\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCovered \/ Enclosed\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-20 to +60 degC (Refer to derating curves for high temperatures)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eUnit Net Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.25 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.45 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe S8JX-G series is a highly reliable legacy line. If you are retrofitting older control panels, note that the S8JX-G series is functionally replaced by the modern \u003cstrong\u003eOmron S8VK-C\u003c\/strong\u003e or \u003cstrong\u003eS8VK-G\u003c\/strong\u003e series. When swapping this unit with an S8VK model, verify depth dimensions and terminal layout, as the S8VK utilizes a slimmer, deeper profile compared to the flatter, wider footprint of the S8JX.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThermal management is critical for the S8JX-G10024CD. In fully enclosed panels operating at ambient temperatures above 40 degC, output derating must be strictly applied. Avoid mounting multiple units side-by-side without at least a 15 mm air gap, as localized heat build-up will trigger the internal thermal protection or shorten the lifetime of the input electrolytic capacitors.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen connecting the input AC mains, ensure the protective earth (PE) terminal is securely grounded to the panel backplate to minimize high-frequency switching noise. If you utilize the front V.ADJ potentiometer to raise the output voltage to compensate for long field cable runs, verify that the terminal output does not exceed 27.6 VDC, as this can trigger the internal overvoltage protection (OVP) circuit and cause intermittent power cycling.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages are present on the input terminals of this device. Ensure all AC mains feed breakers are physically locked out and tagged out (LOTO) and verify zero voltage on all incoming wiring before starting the installation. Do not operate the unit with the terminal cover removed.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; color: #2d3748; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"margin: 0; padding-top: 3px;\"\u003eMount the power supply vertically onto standard 35 mm DIN rail (DIN EN 50022), ensuring the ventilation slots on the top and bottom are completely unobstructed.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"margin: 0; padding-top: 3px;\"\u003eConnect a dedicated copper ground wire to the Protective Earth terminal. Do not chain this ground connection through other control panel devices.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"margin: 0; padding-top: 3px;\"\u003eTerminate the single-phase AC input lines (Line and Neutral) using insulated crimp terminals. Tighten terminal screws to the manufacturer-specified torque of 0.8 N-m to prevent loose-connection heating.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"margin: 0; padding-top: 3px;\"\u003eConnect the positive and negative 24 VDC output load wires. Turn on the AC mains, observe the green DC ON LED indicator, and check output voltage levels before applying load.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077933425003,"sku":"S8JX-G10024CD","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/s8jx-g10024cd-npmrxqiqbd4.png?v=1775734073","url":"https:\/\/www.plcprotech.com\/fa\/products\/omron-s8jx-g10024cd-s8jx-switch-mode-power-supply","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}